Chemometric utilities to achieve robustness in liquid NIRS calibrations:: Application to pig fat analysis

被引:26
作者
Perez-Marin, D. [1 ]
Garrido-Varo, A. [1 ]
De Pedro, E. [1 ]
Guerrero-Ginel, J. E. [1 ]
机构
[1] Univ Cordoba, Dept Anim Prod, E-14071 Cordoba, Spain
关键词
NIRS; Iberian pork fat; fatty acids; calibrations; repeatability file;
D O I
10.1016/j.chemolab.2007.02.004
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Previous research has demonstrated the ability of Near Infrared Reflectance Spectroscopy (NIRS) technology to predict fatty acids in fats and oils with a high degree of precision and accuracy. Nonetheless, it has been noted that when calibrations are applied to external validation samples, considerable deviations from expected values have been detected, despite sample analytical characteristics being well represented in the calibration set. Deviations appear to be greater as the time elapsing between calibration development and NIRS analysis of new unknown samples increases. This problem, which is common to other spectroscopy applications, appears mainly to affect NIRS analysis of oils and fats. The aim of this study was to evaluate the performance of the repeatability file algorithm for minimising the sources of variation that may prompt unexpected predictions of fatty acids in the NIRS analysis of pork fat. A total of 188 samples of Iberian pork fat used as the calibration set, and 12 further samples as the validation set, were analysed in a NIR (Near Infrared Reflectance) monochromator, using folded transmission cups. The results showed that although the use of a repeatability file did not improve the calibration statistics obtained, it enhanced predictive capacity for new samples whose spectra were recorded two months after calibrations were obtained. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:241 / 246
页数:6
相关论文
共 19 条
[1]   Transfer by orthogonal projection: making near-infrared calibrations robust to between-instrument variation [J].
Andrew, A ;
Fearn, T .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2004, 72 (01) :51-56
[2]   PREDICTION OF ORGANIC-MATTER DIGESTIBILITY IN-VIVO OF GRASS-SILAGE BY NEAR-INFRARED REFLECTANCE SPECTROSCOPY - EFFECT OF CALIBRATION METHOD, RESIDUAL MOISTURE AND PARTICLE-SIZE [J].
BAKER, CW ;
GIVENS, DI ;
DEAVILLE, ER .
ANIMAL FEED SCIENCE AND TECHNOLOGY, 1994, 50 (1-2) :17-26
[3]   STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA [J].
BARNES, RJ ;
DHANOA, MS ;
LISTER, SJ .
APPLIED SPECTROSCOPY, 1989, 43 (05) :772-777
[4]   Amino acid contents in raw materials can be precisely analyzed in a global network of near-infrared spectrometers:: Collaborative trials prove the positive effects of instrument standardization and repeatability files [J].
Fontaine, J ;
Hörr, J ;
Schirmer, B .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (04) :701-708
[5]   The transfer of fatty acid calibration equations using four sets of unsealed liquid standardisation samples [J].
García-Olmo, J ;
Garrido-Varo, A ;
De Pedro, E .
JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2001, 9 (01) :49-62
[6]  
Garrido A., 2004, NEAR INFRARED SPECTR, V44, P487
[7]   Determination of fatty acid composition of pork fat by Fourier transform infrared spectroscopy [J].
Ripoche, A ;
Guillard, AS .
MEAT SCIENCE, 2001, 58 (03) :299-304
[8]   POPULATION DEFINITION, SAMPLE SELECTION, AND CALIBRATION PROCEDURES FOR NEAR-INFRARED REFLECTANCE SPECTROSCOPY [J].
SHENK, JS ;
WESTERHAUS, MO .
CROP SCIENCE, 1991, 31 (02) :469-474
[9]   Networking of near infrared spectroscopy instruments for rapeseed analysis: a comparison of different procedures [J].
Tillmann, P ;
Reinhardt, TC ;
Paul, C .
JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2000, 8 (02) :101-107
[10]  
Westerhaus MO, 1990, P 3 INT C NEAR INFR, P671