Automated segmentation of the corneal endothelium in a large set of 'real-world' specular microscopy images using the U-Net architecture

被引:37
作者
Daniel, Moritz C. [1 ]
Atzrodt, Lisa [1 ]
Bucher, Felicitas [1 ]
Wacker, Katrin [1 ]
Bohringer, Stefan [2 ]
Reinhard, Thomas [1 ]
Boehringer, Daniel [1 ]
机构
[1] Univ Freiburg, Ctr Eye, Med Ctr, Freiburg, Germany
[2] Leiden Univ, Dept Biomed Data Sci, Med Ctr, Leiden, Netherlands
关键词
D O I
10.1038/s41598-019-41034-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Monitoring the density of corneal endothelial cells (CEC) is essential in the management of corneal diseases. Its manual calculation is time consuming and prone to errors. U-Net, a neural network for biomedical image segmentation, has shown promising results in the automated segmentation of images of healthy corneas and good quality. The purpose of this study was to assess its performance in "real-world" CEC images (variable quality, different ophthalmologic diseases). The outcome measures were: precision and recall of the extraction of CEC, correctness of CEC density estimation, detection of ungradable images. A classical approach based on grayscale morphology and water shedding was pursued for comparison. There was good agreement between the automated image analysis and the manual annotation from the U-Net. R-square from Pearson's correlation was 0.96. Recall of CEC averaged 0.34 and precision 0.84. The U-Net correctly predicted the CEC density in a large set of images of healthy and diseased corneas, including images of poor quality. It robustly ignored image regions with poor visibility of CEC. The classical approach, however, did not provide acceptable results. R-square from Pearson's correlation with the ground truth was as low as 0.35.
引用
收藏
页数:7
相关论文
共 27 条
  • [1] The Endothelial Sample Size Analysis in Corneal Specular Microscopy Clinical Examinations
    Abib, Fernando C.
    Holzchuh, Ricardo
    Schaefer, Artur
    Schaefer, Tania
    Godois, Ronialci
    [J]. CORNEA, 2012, 31 (05) : 546 - 550
  • [2] Radio frequency interference mitigation using deep convolutional neural networks
    Akeret, J.
    Chang, C.
    Lucchi, A.
    Refregier, A.
    [J]. ASTRONOMY AND COMPUTING, 2017, 18 : 35 - 39
  • [3] A fully automated cell segmentation and morphometric parameter system for quantifying corneal endothelial cell morphology
    Al-Fahdawi, Shumoos
    Qahwaji, Rami
    Al-Waisy, Alaas.
    Ipson, Stanley
    Ferdousi, Maryam
    Malik, Rayaz A.
    Brahma, Arun
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2018, 160 : 11 - 23
  • [4] Cell-by-Cell Alignment of Repeated Specular Microscopy Images from the Same Eye
    Boehringer, Daniel
    Lang, Stefan
    Reinhard, Thomas
    [J]. PLOS ONE, 2013, 8 (03):
  • [5] Morphological Comparison of Specular Microscopy Images May Be a More Robust Indicator for Endothelial Stability Than Cell Density Estimations
    Boehringer, Daniel
    Reinhard, Thomas
    [J]. CORNEA, 2013, 32 (03) : 376 - 377
  • [6] Further analysis of assessments of the coefficient of variation of corneal endothelial cell areas from specular microscopic images
    Doughty, Michael J.
    Aakre, Bente Monica
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2008, 91 (05) : 438 - 446
  • [7] Assessment of the reliability of endothelial cell-density estimates in the presence of pseudoguttata
    Doughty, Michael J.
    Jonuscheit, Sven
    Button, Norman F.
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (01) : 111 - 121
  • [9] Segmentation of corneal endothelium images using a U-Net-based convolutional neural network
    Fabijanska, Anna
    [J]. ARTIFICIAL INTELLIGENCE IN MEDICINE, 2018, 88 : 1 - 13
  • [10] Corneal Endothelium Image Segmentation Using Feedforward Neural Network
    Fabijanska, Anna
    [J]. PROCEEDINGS OF THE 2017 FEDERATED CONFERENCE ON COMPUTER SCIENCE AND INFORMATION SYSTEMS (FEDCSIS), 2017, : 629 - 637