Quality control after insertion of the nucleus contour and contour advance electrode in adults

被引:258
作者
Aschendorff, Antje
Kromeier, Jan
Klenzner, Thomas
Laszig, Roland
机构
[1] Univ Freiburg, Dept Otorhinolaryngol, D-79106 Freiburg, Germany
[2] Univ Freiburg, Dept Radiol, D-79106 Freiburg, Germany
关键词
D O I
10.1097/AUD.0b013e318031542e
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective. To evaluate the quality of insertion of the Nucleus Contour and the newly developed Contour Advance electrode in adult cochlear implant recipients and to compare results of speech performance tests with regard to electrode position. Design: A total of 43 adult patients with a history of progressive hearing loss having received a Nucleus cochlear implant, 21 of which had received a Contour electrode and 22 a Contour Advance electrode, were evaluated by rotational tomography after surgery. Electrode position was determined to be in scala tympani, scala vestibuli, or with a dislocation from one scala to the other. Speech test results were collected for Freiburg numbers, Freiburg monosyllables, and Oldenburg sentence tests 1 yr after surgery. Results: The Contour array presented with a high rate of scala vestibuli insertions and a high rate of dislocations from scala tympani to scala vestibuli, whereas the Contour Advance array showed a high rate of scala tympani insertions with very few dislocations and few scala vestibuli insertions. Speech tests results varied with respect to the location of the intracochlear electrode position, with insertions into the scala tympani being significantly superior to the scala vestibuli. Conclusions: Results of studying the Contour array influenced the surgical procedure that improved surgical ability to perform insertions into the scala tympani by using the Contour Advance array. In addition, a comparison between Contour and Contour Advance electrode demonstrated an improved mechanical behavior of the Contour Advance electrode with a decrease of dislocation rate. The use of the Contour Advance electrode allows a more atraumatic electrode insertion, which is of interest with extending indications and the use of further advanced coding strategies. The intracochlear electrode position with regard to speech performance results demonstrated advantages of scala tympani insertions.
引用
收藏
页码:75S / 79S
页数:5
相关论文
共 17 条
  • [1] Quality control after cochlear implant surgery by means of rotational tomography
    Aschendorff, A
    Kubalek, T
    Turowski, B
    Zanella, T
    Hochmuth, T
    Schumacher, T
    Klenzner, T
    Laszig, R
    [J]. OTOLOGY & NEUROTOLOGY, 2005, 26 (01) : 34 - 37
  • [2] Imaging procedures in cochlear implant patients - Evaluation of different radiological techniques
    Aschendorff, A
    Kubalek, R
    Hochmuth, A
    Bink, A
    Kurtz, C
    Lohnstein, P
    Klenzner, T
    Laszig, R
    [J]. ACTA OTO-LARYNGOLOGICA, 2004, 124 : 46 - 49
  • [3] Aschendorff A, 1997, Wien Med Wochenschr, V147, P252
  • [4] Nucleus multichannel cochlear implantation in partially ossified cochleas using the Steenerson procedure
    Bacciu, S
    Bacciu, A
    Pasanisi, E
    Vincenti, V
    Guida, M
    Barbot, A
    Berghenti, T
    [J]. OTOLOGY & NEUROTOLOGY, 2002, 23 (03) : 341 - 345
  • [5] Scala vestibuli cochlear implantation in patients with partially ossified cochleas
    Berrettini, S
    Forli, F
    Neri, E
    Segnini, G
    Franceschini, SS
    [J]. JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2002, 116 (11) : 946 - 950
  • [6] Fraysse B, 1998, AM J OTOL, V19, P591
  • [7] Combining acoustic and electrical hearing
    Gantz, BJ
    Turner, CW
    [J]. LARYNGOSCOPE, 2003, 113 (10) : 1726 - 1730
  • [8] Nondestructive three-dimensional analysis of electrode to modiolus proximity
    Husstedt, HW
    Aschendorff, A
    Richter, B
    Laszig, R
    Schumacher, M
    [J]. OTOLOGY & NEUROTOLOGY, 2002, 23 (01) : 49 - 52
  • [9] ILBERG VC, 1999, J OTORHINOLARYNGOLOG, V61, P334
  • [10] Ketten DR, 1998, ANN OTO RHINOL LARYN, V107, P1