A hybrid model approach for forecasting future residential electricity consumption

被引:141
作者
Dong, Bing [1 ]
Li, Zhaoxuan [1 ]
Rahman, S. M. Mahbobur [1 ]
Vega, Rolando [2 ]
机构
[1] Univ Texas San Antonio, Dept Mech Engn, San Antonio, TX USA
[2] Univ Texas San Antonio, Texas Sustainable Energy Res Inst, San Antonio, TX USA
关键词
Load forecasting; Data-driven model; Thermal network; Residential houses; ENERGY-CONSUMPTION; LOAD PREDICTION; BOX MODEL; PERFORMANCE; NETWORK;
D O I
10.1016/j.enbuild.2015.09.033
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Urban energy management nowadays has put more focus on residential houses energy consumption. Lots of machine learning based data-driven approaches have the abilities to characterize and forecast total energy consumption of commercial data. However, a paucity of research applying data-driven methods have been tested on the hour ahead energy consumption forecast for typical single family houses in the US. With the advances in smart metering, sub meter usages forecast in household-level is also getting more and more popular on smart building control and demand response program. The situation here inspires us to develop a hybrid model to address the problem of residential hour and day ahead load forecasting through the integration of data-driven techniques with a physics-based model. In this article, we report on the evaluations of five different machine learning algorithms, artificial neural network (ANN), support vector regression (SVR), least-square support vector machine (LS-SVM), Gaussian process regression (GPR) and Gaussian mixture model (GMM), applied to four residential data set that contains smart meters. Both total and non-air conditioning (AC) power consumption are forecasted for hour ahead and 24-h ahead. The variation of patterns captured from non-AC part is further input as internal heat gain to a physics-based model. The model uses a 2R-1C thermal network and an AC regression model. By utilizing this hybrid approach, we get AC load prediction and non-AC energy forecast simultaneously. Total energy consumption is further produced by summing up the two sub meters forecast for hybrid model. The results from new modeling are compared with those from pure data-driven techniques. The final result showing improvements of coefficient of variance between the best data-driven model and hybrid model are 6-10% and 2-15% for hour ahead and 24-h ahead, respectively. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:341 / 351
页数:11
相关论文
共 52 条
  • [1] A review on applications of ANN and SVM for building electrical energy consumption forecasting
    Ahmad, A. S.
    Hassan, M. Y.
    Abdullah, M. P.
    Rahman, H. A.
    Hussin, F.
    Abdullah, H.
    Saidur, R.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 33 : 102 - 109
  • [2] American Society of Heating Refrigerating and Air Conditioning Engineers (ASHRAE), 2013, ASHRAE HDB FUND
  • [3] American Society of Heating Refrigerating and Air Conditioning Engineers Inc., 2011, 140 ANSIASHRAEIES
  • [4] [Anonymous], 2010, BUILD EN DAT BOOK
  • [5] Modeling of the space and domestic hot-water heating energy-consumption in the residential sector using neural networks
    Aydinalp, M
    Ugursal, VI
    Fung, AS
    [J]. APPLIED ENERGY, 2004, 79 (02) : 159 - 178
  • [6] Annual electricity consumption forecasting by neural network in high energy consuming industrial sectors
    Azadeh, A.
    Ghaderi, S. F.
    Sohrabkhani, S.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (08) : 2272 - 2278
  • [7] Cooling load prediction for buildings using general regression neural networks
    Ben-Nakhi, AE
    Mahmoud, MA
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (13-14) : 2127 - 2141
  • [8] Bertagnolio S., 2008, 3 NAT C IBPSA US BER
  • [9] Brabanter K.D., 2011, TECHNICAL REPORT
  • [10] An inverse gray-box model for transient building load prediction
    Braun, JE
    Chaturvedi, N
    [J]. HVAC&R RESEARCH, 2002, 8 (01): : 73 - 99