Purpose: In this study, a 3D phase correlation algorithm was investigated to test feasibility for use in determining the anatomical changes that occur throughout a patient's radiotherapy treatment. The algorithm determines the transformations between two image volumes through analysis in the Fourier domain and has not previously been used in radiotherapy for 3D registration of CT and CBCT volumes. Methods: Various known transformations were applied to a patient's prostate CT image volume to create 12 different test cases. The mean absolute error and standard deviation were determined by evaluating the difference between the known contours and those calculated from the registration process on a point-by-point basis. Similar evaluations were performed on images with increasing levels of noise added. The improvement in structure overlap offered by the algorithm in registering clinical CBCT to CT images was evaluated using the Dice Similarity Coefficient (DSC). Results: A mean error of 2.35 (sigma = 1.54) mm was calculated for the 12 deformations applied. When increasing levels of noise were introduced to the images, the mean errors were observed to rise up to a maximum increase of 1.77 mm. For CBCT to CT registration, maximum improvements in the DSC of 0.09 and 0.46 were observed for the bladder and rectum, respectively. Conclusions: The Fourier-based 3D phase correlation registration algorithm investigated displayed promising results in CT to CT and CT to CBCT registration, offers potential in terms of efficiency and robustness to noise, and is suitable for use in radiotherapy for monitoring patient anatomy throughout treatment. (C) 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:618 / 624
页数:7
相关论文
共 50 条
  • [1] 3D Rigid registration by cylindrical phase correlation method
    Bican, Jakub
    Flusser, Jan
    PATTERN RECOGNITION LETTERS, 2009, 30 (10) : 914 - 921
  • [2] Object-constrained meshless deformable algorithm for high speed 3D nonrigid registration between CT and CBCT
    Chen, Ting
    Kim, Sung
    Goyal, Sharad
    Jabbour, Salma
    Zhou, Jinghao
    Rajagopal, Gunaretnum
    Haffty, Bruce
    Yue, Ning
    MEDICAL PHYSICS, 2010, 37 (01) : 197 - 210
  • [3] A Hybrid 3D Image Registration of Lung CT Images for Respiration
    Liang Rui
    Zhang Jian Xun
    Wang Ruo Fan
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 4182 - 4187
  • [4] 3D pulmonary CT image registration with a standard lung atlas
    Zhang, L
    Reinhardt, JM
    MEDICAL IMAGING 2000: PHYSIOLOGY AND FUNCTION FORM MULTIDIMENSIONAL IMAGES, 2000, 3978 : 67 - 77
  • [5] Pulmonary CT image registration and warping for tracking tissue deformation during the respiratory cycle through 3D consistent image registration
    Li, Baojun
    Christensen, Gary E.
    Hoffman, Eric A.
    McLennan, Geoffrey
    Reinhardt, Joseph M.
    MEDICAL PHYSICS, 2008, 35 (12) : 5575 - 5583
  • [6] Accelerated 3D image registration
    Vester-Christensen, Martin
    Erbou, Soren G.
    Darkner, Sune
    Larsen, Rasmus
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [7] CCMNet: Cross-scale correlation-aware mapping network for 3D lung CT image registration
    Long, Li
    Xue, Xufeng
    Xiao, Hanguang
    Computers in Biology and Medicine, 2024, 182
  • [8] An improvement of image registration based on phase correlation
    Ge, Peng
    Lan, Caiyu
    Wang, Hong
    OPTIK, 2014, 125 (22): : 6709 - 6712
  • [9] 3D breast image registration - A review
    Sivaramakrishna, R
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2005, 4 (01) : 39 - 48
  • [10] INTERACTIVE 3D PATIENT - IMAGE REGISTRATION
    PELIZZARI, CA
    TAN, KK
    LEVIN, DN
    CHEN, GTY
    BALTER, J
    LECTURE NOTES IN COMPUTER SCIENCE, 1991, 511 : 132 - 141