Determination of fluoroquinolone antibiotics in environmental water samples based on magnetic molecularly imprinted polymer extraction followed by liquid chromatography-tandem mass spectrometry

被引:180
作者
Chen, Ligang [1 ]
Zhang, Xiaopan [1 ]
Xu, Yang [1 ]
Du, Xiaobo [2 ]
Sun, Xin [2 ]
Sun, Lei [1 ]
Wang, Hui [1 ]
Zhao, Qi [1 ]
Yu, Aimin [1 ]
Zhang, Hanqi [1 ]
Ding, Lan [1 ]
机构
[1] Jilin Univ, Coll Chem, Changchun 130012, Jilin, Peoples R China
[2] Jilin Univ, Coll Phys, Changchun 130012, Jilin, Peoples R China
关键词
Magnetic molecularly imprinted polymer; Fluoroquinolone antibiotics; Environmental water; Liquid chromatography-tandem mass spectrometry; SOLID-PHASE EXTRACTION; POLYCYCLIC AROMATIC-HYDROCARBONS; SULFONAMIDE ANTIBIOTICS; SUBMICROMETER PARTICLES; RECOGNITION; SUSCEPTIBILITY; MICROSPHERES; QUINOLONES; BEADS; MICROEXTRACTION;
D O I
10.1016/j.aca.2010.01.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple method based on magnetic separation for selective extraction of fluoroquinolones (FQs) from environmental water samples has been developed using magnetic molecularly imprinted polymer (MMIP) as sorbent. The MMIP has been prepared using ciprofloxacin as template molecule, methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linking agent and Fe3O4 magnetite as magnetic component. The polymer has been characterized by scanning electron microscopy, Fourier-transform infrared spectrometry and vibrating sample magnetometry. Various parameters affecting the extraction efficiency were evaluated in order to achieve optimal concentration and reduce non-specific interactions. The analytes desorbed from the polymers were determined by liquid chromatography-tandem mass spectrometry. The matrix effect was evaluated by using different washing solvents for removing interfering compounds from the MMIPs after sample loading. Under the optimal conditions, the linearity of the method obtained is in the range of 20-2000 ng L-1. The detection limits of FQs are in the range of 3.2-6.2 ng L-1. The relative standard deviations of intra- and inter-day tests ranging from 2.5 to 7.2% and from 3.6 to 9.1% are obtained. In all three spiked levels (20, 100 and 200 ng L-1), the recoveries of FQs are in the range of 76.3-94.2%. The proposed method was successfully applied to determine FQs including ciprofloxacin, enrofloxacin, lomefloxacin, levofloxacin, fleroxacin and sparfloxacin in different water samples, such as lake water, river water, primary and final sewage effluent. Ciprofloxacin and fleroxacin were found in primary and final sewage effluent samples with the contents in the range of 26-87 ng L-1. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 40 条
[31]   Recognition mechanism of water-compatible molecularly imprinted solid-phase extraction and determination of nine quinolones in urine by high performance liquid chromatography [J].
Sun, Han-wen ;
Qiao, Feng-xia .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1212 (1-2) :1-9
[32]   Molecularly imprinted polymers for solid-phase extraction and solid-phase microextraction:: Recent developments and future trends [J].
Tamayo, F. G. ;
Turiel, E. ;
Martin-Esteban, A. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1152 (1-2) :32-40
[33]   Preparation of bovine serum albumin surface-imprinted submicrometer particles with magnetic susceptibility through core-shell miniemulsion polymerization [J].
Tan, Chau Jin ;
Chua, Mong Gap ;
Ker, Kwee Hong ;
Tong, Yen Wah .
ANALYTICAL CHEMISTRY, 2008, 80 (03) :683-692
[34]   Preparation of superparamagnetic ribonuclease A surface-imprinted submicrometer particles for protein recognition in aqueous media [J].
Tan, Chau Jin ;
Tong, Yen Wah .
ANALYTICAL CHEMISTRY, 2007, 79 (01) :299-306
[35]   Multiresidue analysis of quinolones and fluoroquinolones in soil by ultrasonic-assisted extraction in small columns and HPLC-UV [J].
Turiel, E ;
Martín-Esteban, A ;
Tadeo, JL .
ANALYTICA CHIMICA ACTA, 2006, 562 (01) :30-35
[36]   Determination of quinolones and fluoroquinolones in hospital sewage water by off-line and on-line solid-phase extraction procedures coupled to HPLC-UV [J].
Turiel, E ;
Bordin, G ;
Rodríguez, AR .
JOURNAL OF SEPARATION SCIENCE, 2005, 28 (03) :257-267
[37]   Molecular imprinting-based separation methods for selective analysis of fluoroquinolones in soils [J].
Turiel, Esther ;
Martin-Esteban, Antonio ;
Tadeo, Jose Luis .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1172 (02) :97-104
[38]   Molecularly imprinted-matrix solid-phase dispersion for selective extraction of five fluoroquinolones in eggs and tissue [J].
Yan, Hongyuan ;
Qiao, Fengxia ;
Row, Kyung Ho .
ANALYTICAL CHEMISTRY, 2007, 79 (21) :8242-8248
[39]   Novel surface modified molecularly imprinted polymer using acryloyl-β-cyclodextrin and acrylamide as monomers for selective recognition of lysozyme in aqueous solution [J].
Zhang, Wei ;
Qin, Lei ;
He, Xi-Wen ;
Li, Wen-You ;
Zhang, Yu-Kui .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (21) :4560-4567
[40]   Microwave Heating in Preparation of Magnetic Molecularly Imprinted Polymer Beads for Trace Triazines Analysis in Complicated Samples [J].
Zhang, Yi ;
Liu, Ruijin ;
Hu, Yuling ;
Li, Gongke .
ANALYTICAL CHEMISTRY, 2009, 81 (03) :967-976