Leakage current in high-purity germanium detectors with amorphous semiconductor contacts

被引:15
作者
Looker, Q. [1 ,2 ]
Amman, M. [1 ]
Vetter, K. [1 ,2 ]
机构
[1] Univ Calif Berkeley, Ernest Orlando Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Dept Nucl Engn, Berkeley, CA 94720 USA
关键词
Gamma-ray detectors; High-parity germanium; Radiation detectors; Semiconductor radiation detectors; STRIP DETECTORS; SILICON; FABRICATION; OPERATION; BARRIER; LAYER;
D O I
10.1016/j.nima.2014.12.104
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Amorphous semiconductor electrical contacts on high purity Ge radiation detectors have become a valuable technology because they are simple to fabricate, result in thin dead layers, block both electron and hole injection, and can readily be finely segmented as needed for applications requiring imaging or particle tracking. Though significant numbers of detectors have been successfully produced for a variety of applications using the amorphous semiconductor contact technology, there remains a need to better understand the dependence of performance characteristics, particularly leakage current, on the fabrication process parameters so that the performance can be better optimized. To this end, we have performed a systematic study of leakage current on BF-sputter-deposited amorphous-Ge (a-Ge) and amorphous-Si (a-Si) contacts as a function of process and operational parameters including sputter gas pressure and composition, number of detector temperature cycles, and time spent at room temperature. The study focused primarily on the current resulting from electron injection at the contact. Significant findings from the study include that a-Si produces lower electron injection than a-Ge, the time the detector spends at room temperature rather than the number of temperature cycles experienced by the detector is the primary factor associated with leakage current change when the detector is warmed, and the time stability of the a-Ge contact depends on the sputter gas pressure with a higher pressure producing more stable characteristics. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 147
页数:10
相关论文
共 55 条
[1]   GERMANIUM MICROSTRIP DETECTORS WITH 50 AND 100 MU-M PITCH [J].
AMENDOLIA, SR ;
BEDESCHI, F ;
BERTOLUCCI, E ;
BETTONI, D ;
BOSISIO, L ;
BOTTIGLI, U ;
BRADASCHIA, C ;
DELLORSO, M ;
FIDECARO, F ;
FOA, L ;
FOCARDI, E ;
GIANNETTI, P ;
GIORGI, MA ;
MARROCCHESI, PS ;
MENZIONE, A ;
RASO, G ;
RISTORI, L ;
SCRIBANO, A ;
STEFANINI, A ;
TENCHINI, R ;
TONELLI, G ;
TRIGGIANI, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 226 (01) :117-121
[2]   Three-dimensional position sensing and field shaping in orthogonal-strip germanium gamma-ray detectors [J].
Amman, M ;
Luke, PN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 452 (1-2) :155-166
[3]   Amorphous-semiconductor-contact germanium-based detectors for gamma-ray imaging and spectroscopy [J].
Amman, M. ;
Luke, P. N. ;
Boggs, S. E. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (02) :886-890
[4]   Position-sensitive germanium detectors for gamma-ray imaging and spectroscopy [J].
Amman, M ;
Luke, PN .
HARD X-RAY GAMMA-RAY AND NEUTRON DETECTOR PHYSICS II, 2000, 4141 :144-156
[5]   Proximity Electrode Signal Readout of High-Purity Ge Detectors [J].
Amman, Mark ;
Priest, Anders ;
Luke, Paul N. ;
Asztalos, Stephen ;
Sabourov, Konstantin ;
Vetter, Kai .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) :1213-1218
[6]   DETECTION AND IMAGING OF THE CRAB NEBULA WITH THE NUCLEAR COMPTON TELESCOPE [J].
Bandstra, M. S. ;
Bellm, E. C. ;
Boggs, S. E. ;
Perez-Becker, D. ;
Zoglauer, A. ;
Chang, H. -K. ;
Chiu, J. -L. ;
Liang, J. -S. ;
Chang, Y. -H. ;
Liu, Z. -K. ;
Hung, W. -C. ;
Huang, M. -H. A. ;
Chiang, S. J. ;
Run, R. -S. ;
Lin, C. -H. ;
Amman, M. ;
Luke, P. N. ;
Jean, P. ;
von Ballmoos, P. ;
Wunderer, C. B. .
ASTROPHYSICAL JOURNAL, 2011, 738 (01)
[7]  
BELLM EC, 2010, P SPIE, V7732
[8]   Overview of the Nuclear Compton Telescope [J].
Bellm, Eric C. ;
Boggs, Steven E. ;
Bandstra, Mark S. ;
Bowen, Jason D. ;
Perez-Becker, Daniel ;
Wunderer, Cornelia B. ;
Zoglauer, Andreas ;
Amman, Mark ;
Luke, Paul N. ;
Chang, Hsiang-Kuang ;
Chiu, Jeng-Lun ;
Liang, Jau-Shian ;
Chang, Yuan-Hann ;
Liu, Zong-Kai ;
Hung, Wei-Che ;
Lin, Chih-Hsun ;
Huang, Minghuey A. ;
Jean, Pierre .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) :1250-1256
[9]   Performance of the Nuclear Compton Telescope [J].
Boggs, Steven ;
Bandstra, Mark ;
Bowen, Jason ;
Coburn, Wayne ;
Lin, Robert ;
Wunderer, Cornelia ;
Zoglauer, Andreas ;
Amman, Mark ;
Luke, Paul ;
Jean, Pierre ;
von Ballmoos, Peter .
EXPERIMENTAL ASTRONOMY, 2005, 20 (1-3) :389-396
[10]   SuperCDMS Detector Fabrication Advances [J].
Brink, P. L. ;
Ahmed, Z. ;
Akerib, D. S. ;
Bailey, C. N. ;
Balakishiyeva, D. ;
Bauer, D. A. ;
Beaty, J. ;
Bunker, R. ;
Cabrera, B. ;
Caldwell, D. O. ;
Cooley, J. ;
do Couto e Silva, E. ;
Cushman, P. ;
Daal, M. ;
DeJongh, F. ;
Dragowsky, M. R. ;
Duong, L. ;
Figueroa-Feliciano, E. ;
Filippini, J. ;
Fritts, M. ;
Golwala, S. R. ;
Grant, D. R. ;
Hall, J. ;
Hennings-Yeomans, R. ;
Hertel, S. ;
Hojem, A. ;
Holmgren, D. ;
Hsu, L. ;
Huber, M. E. ;
Irwin, K. D. ;
Kamaev, O. ;
Kos, M. ;
Kiveni, M. ;
Leman, S. W. ;
Mahapatra, R. ;
Mandic, V. ;
McCarthy, K. A. ;
Moore, D. ;
Mirabolfathi, N. ;
Nelson, H. ;
Novak, L. ;
Ogburn, R. W. ;
Pyle, M. ;
Qiu, X. ;
Ramberg, E. ;
Rau, W. ;
Reisetter, A. ;
Saab, T. ;
Sadoulet, B. ;
Sander, J. .
LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 :655-+