First/Preliminary Experience of Gore Viabahn Balloon-Expandable Endoprosthesis as Bridging Stent in Fenestrated and Branched Endovascular Aortic Repair

被引:18
作者
Gallitto, Enrico [1 ]
Faggioli, Gianluca [1 ]
Pini, Rodolfo [1 ]
Mascoli, Chiara [1 ]
Sonetto, Alessia [1 ]
Abualhin, Mohammad [1 ]
Logiacco, Antonino [1 ]
Ricco, Jean-Baptiste [2 ]
Gargiulo, Mauro [1 ]
机构
[1] Univ Bologna, Dept Expt Diagnost & Specialty Med, Policlin St Orsola Malpighi, Vasc Surg, Bologna, Italy
[2] Univ Hosp Poitiers, DRCI, Poitiers, France
关键词
SPINAL-CORD ISCHEMIA; EDITORS CHOICE; ANEURYSM REPAIR; OUTCOMES; GRAFTS; IMPACT;
D O I
10.1016/j.avsg.2019.04.049
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The aim of this study is to evaluate the preliminary outcomes of the Gore (R) Viabahn (R) balloon-expandable endoprosthesis (VBX) as bridging stent for fenestrated/branched aortic endograft. Methods: Between April and June 2018, patients undergoing fenestrated and branched-endovascular aortic repair were prospectively collected. Anatomical, procedural, and post-operative data of patients treated with VBX as bridging stents to connect fenestrations/branches to target visceral vessels (TVVs) were analyzed. Technical success and any TVV- related adverse event were assessed before discharge, at 30 days, and after 6 months of follow-up. Results: Fifteen patients undergoing fenestrated and branched-endovascular aortic repair for juxta/pararenal aneurysms (11), proximal type I endoleak after endovascular aortic repair (1), and thoracoabdominal aneurysms (3) were included in the study. Overall, 60 TVVs-celiac trunk (n = 14), superior mesenteric artery (n = 13), renal arteries (n = 30), hypogastric artery (n = 3)-were accommodated by fenestrations (n = 51), branches (n = 7), and scallops (n = 2). The bridging stent graft was a VBX in 40 (67%) TVVs. A renal artery dissection was successfully managed by a self-expandable bare metal stent. Overall, relining of a bridging stent graft was required in 2 TVVs revascularized by fenestrations (superior mesenteric artery: n = 1, renal artery: n = 1). One intraoperative type III endoleak from renal fenestration was detected and successfully sealed by an adjunctive flaring maneuver. Technical success was achieved in all cases. At 5-day, 1 VBX (1/40: 2.5%) lost its sealing in a renal artery revascularized by a branch (type II thoracoabdominal aortic aneurysm) and required reintervention and relining with a self-expandable stent graft. No TVV occlusion or reintervention occurred <30 days or after 6 months of follow-up. Conclusions: According to these preliminary results, the Gore Viabahn VBX balloon-expandable endoprosthesis can be safely used as bridging stent graft for fenestrated or branched endografts. A longer follow-up with a larger case load is necessary in order to validate this preliminary experience.
引用
收藏
页码:299 / 309
页数:11
相关论文
共 50 条
  • [31] European Multicentric Experience With Fenestrated-branched ENDOvascular Stent Grafting After Previous FAILed Infrarenal Aortic Repair The EU-FBENDO-FAIL Registry
    Budtz-Lilly, Jacob
    D'Oria, Mario
    Gallitto, Enrico
    Bertoglio, Luca
    Koelbel, Tilo
    Lindstrom, David
    Dias, Nuno
    Lundberg, Goran
    Boeckler, Dittmar
    Parlani, Gianbattista
    Antonello, Michele
    Veraldi, Gian F.
    Tsilimparis, Nikolaos
    Kotelis, Drosos
    Dueppers, Philip
    Tinelli, Giovanni
    Ippoliti, Arnaldo
    Spath, Paolo
    Logiacco, Antonino
    Schurink, Geert Willem H.
    Chiesa, Roberto
    Grandi, Alessandro
    Panuccio, Giuseppe
    Rohlffs, Fiona
    Wanhainen, Anders
    Mani, Kevin
    Karelis, Angelos
    Sonesson, Bjorn
    Jonsson, Magnus
    Bresler, Alina-Marilena
    Simonte, Gioele
    Isernia, Giacomo
    Xodo, Andrea
    Mezzetto, Luca
    Mastrorilli, Davide
    Prendes, Carlota F.
    Chaikhouni, Basel
    Zimmermann, Alexander
    Lepidi, Sandro
    Gargiulo, Mauro
    Mees, Barend
    Unosson, Jon
    ANNALS OF SURGERY, 2023, 278 (02) : E389 - E395
  • [32] Comparison of BARD®LIFESTREAM™ covered balloon-expandable stent versus GORE® VIABAHN™ covered self-expandable stent in treatment of aortoiliac obstructive disease: study protocol for a prospective randomized controlled trial (NEONATAL trial)
    Qi, Yuhan
    Wang, Jiarong
    Zhao, Jichun
    Huang, Bing
    Xiong, Fei
    Du, Xiaojiong
    Chen, Xiyang
    Guo, Qiang
    Wang, Tiehao
    Yuan, Ding
    TRIALS, 2022, 23 (01)
  • [33] Three-Dimensional Geometric Analysis of Balloon-Expandable Covered Stents Improves Classification of Complications after Fenestrated Endovascular Aneurysm Repair
    van der Riet, Claire
    Schuurmann, Richte C. L.
    Verhoeven, Eric L. G.
    Katsargyris, Athanasios
    Tielliu, Ignace F. J.
    Resch, Timothy
    Bokkers, Reinoud P. H.
    De Vries, Jean-Paul P. M.
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (19)
  • [34] Bridging stent graft fracture after branched endovascular aortic repair in a dual-center retrospective cohort study
    Gennai, Stefano
    Simonte, Gioele
    Migliari, Mattia
    Isernia, Giacomo
    Leone, Nicola
    Casali, Francesco
    Farchioni, Luca
    Lenti, Massimo
    Silingardi, Roberto
    JOURNAL OF VASCULAR SURGERY, 2022, 75 (02) : 425 - 432
  • [35] Stent and leaflet stresses in a 26-mm first-generation balloon-expandable transcatheter aortic valve
    Xuan, Yue
    Krishnan, Kapil
    Ye, Jian
    Dvir, Danny
    Guccione, Julius M.
    Ge, Liang
    Tseng, Elaine E.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (05) : 1065 - 1073
  • [36] Aneurysm Rupture and Mortality During the Waiting Time for a Customised Fenestrated/Branched Stent Graft in Complex Endovascular Aortic Repair
    Katsargyris, Athanasios
    Uthayakumar, Vasuki
    de Marino, Pablo Marques
    Botos, Balazs
    Verhoeven, Eric L.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2020, 60 (01) : 44 - 48
  • [37] Modified Double-Fenestrated Stent Graft for Branched Thoracic Endovascular Aortic Repair of an Irregular Aortic Arch Aneurysm: A Case Report
    He, Xiaofeng
    Zhang, Lei
    Liu, Xuanze
    Wang, Xiaozeng
    CARDIOLOGY DISCOVERY, 2023, 3 (01): : 54 - 59
  • [38] Impact of bridging stent design and configuration on branch vessel durability after fenestrated endovascular repair of complex aortic aneurysms
    Farivar, Behzad S.
    Brier, Corey
    Kuramochi, Yuki
    Eagleton, Matthew J.
    JOURNAL OF VASCULAR SURGERY, 2021, 73 (03) : 819 - 825
  • [39] Cerebrospinal fluid drainage complications during first stage and completion fenestrated-branched endovascular aortic repair
    Karkkainen, Jussi M.
    Cirillo-Penn, Nolan C.
    Sen, Indrani
    Tenorio, Emanuel R.
    Mauermann, William J.
    Gilkey, George D.
    Kaufmann, Timothy J.
    Oderich, Gustavo S.
    JOURNAL OF VASCULAR SURGERY, 2020, 71 (04) : 1109 - +
  • [40] Outcomes of endovascular repair of chronic postdissection compared with degenerative thoracoabdominal aortic aneurysms using fenestrated-branched stent grafts
    Tenorio, Emanuel R.
    Oderich, Gustavo S.
    Farber, Mark A.
    Schneider, Darren B.
    Timaran, Carlos H.
    Schanzer, Andres
    Beck, Adam W.
    Motta, Fernando
    Sweet, Matthew P.
    JOURNAL OF VASCULAR SURGERY, 2020, 72 (03) : 822 - +