A Comparative Study on Energy Efficiency and Indoor Thermal Comfort of DOAS Applied to Multi-zone Air-conditioning Systems

被引:0
|
作者
Ge, Gaoming [1 ]
Xiao, Fu [1 ]
Zhang, Lizhi
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
Dedicated outdoor air system; Multi-zone air-conditioning; Thermal comfort; Building energy efficiency; CONTROL STRATEGIES;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Conventional air conditioning systems are facing great challenges considering indoor relative humidity control, system safety and effective ventilation in an energy efficient way. The dedicated outdoor air system (DOAS) is widely believed to overcome these problems. A DOAS-integrated system, which combines a DOAS with dry fan-coil units, is presented in this study. Energy efficiency and indoor thermal comfort of this air-conditioning scheme is investigated and compared with two conventional systems, i.e. wet fan-coil units and variable air volume systems, serving the same multi-zone space of an office building in Hong Kong. Control strategies for the DOAS-integrated system are also presented. Tests on two typical operation conditions, i.e. summer day and spring day, are conducted on the simulation platform of TRNSYS. Simulation results show that the DOAS-integrated dry fan-coil unit system can achieve the best indoor relative humidity on two typical days, and it consumes almost the same amount of energy as the wet fan-coil unit system on the summer day and about 5% more energy on the spring day. In addition, the effect of total heat recovery exchanger on energy saving in hot and humid regions is obvious and demonstrated.
引用
收藏
页码:405 / 412
页数:8
相关论文
共 50 条
  • [31] Indoor air quality and energy issues of refrigerant modulating air-conditioning systems in the tropics
    Sekhar, SC
    Lim, AH
    BUILDING AND ENVIRONMENT, 2003, 38 (06) : 815 - 825
  • [32] ENERGY EFFICIENCY OF BUILDINGS AND AIR CONDITIONING SYSTEMS - A COMPARATIVE STUDY.
    Donnelly, E.W.
    Hands, D.J.
    Australian refrigeration, Air conditioning and heating, 1987, 41 (01): : 22 - 24
  • [33] Optimizing HVAC Systems for Energy Efficiency and Comfort: A Scalable and Robust Multi-Zone Control Approach with Uncertainty Considerations
    Xiong, Ruoxin
    Jing, Haoming
    Li, Mengmou
    Shi, Ying
    Miki, Taya
    Hatanaka, Takeshi
    Nakahira, Yorie
    Tang, Pingbo
    COMPUTING IN CIVIL ENGINEERING 2023-RESILIENCE, SAFETY, AND SUSTAINABILITY, 2024, : 987 - 995
  • [34] Numerical study on indoor environment and thermal comfort in train station waiting hall with two different air-conditioning modes
    Biyao Zhuang
    Juan Shi
    Zhenqian Chen
    Building Simulation, 2021, 14 : 337 - 349
  • [35] Numerical study on indoor environment and thermal comfort in train station waiting hall with two different air-conditioning modes
    Zhuang, Biyao
    Shi, Juan
    Chen, Zhenqian
    BUILDING SIMULATION, 2021, 14 (02) : 337 - 349
  • [36] Impact of summer office set air-conditioning temperature on energy consumption and thermal comfort
    刘红
    马小磊
    高亚峰
    Journal of Central South University, 2009, 16 (S1) : 6 - 11
  • [37] Impact of summer office set air-conditioning temperature on energy consumption and thermal comfort
    Liu Hong
    Ma Xiao-lei
    Gao Ya-feng
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2009, 16 : 6 - 11
  • [38] Thermal comfort and energy saving in a vehicle compartment using a localized air-conditioning system
    Oh, Myoung Su
    Ahn, Jae Hwan
    Kim, Dong Woo
    Fang, Dong Soo
    Kim, Yongchan
    APPLIED ENERGY, 2014, 133 : 14 - 21
  • [39] Multi-Agent Control for Centralized Air Conditioning Systems Serving Multi-Zone Buildings
    Cai, Jie
    Kim, Donghun
    Putta, Vamsi K.
    Braun, James E.
    Hu, Jianghai
    2015 AMERICAN CONTROL CONFERENCE (ACC), 2015, : 986 - 993
  • [40] Method for Mapping from Thermal Comfort Requirements to Energy Design Factors of Air-conditioning
    Wang, Yan
    Liu, Guangfu
    Zhang, Lei
    Zhou, Dan
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING, PTS 1-4, 2013, 353-356 : 3145 - 3148