Cost-Effectiveness Evaluation of Nearly Zero-Energy Buildings for the Aging of Red Wine

被引:6
作者
Gomez-Villarino, Maria Teresa [1 ]
Barbero-Barrera, Maria del Mar [2 ]
Mazarron, Fernando R. [1 ]
Canas, Ignacio [1 ]
机构
[1] Univ Politecn Madrid, Agroforestry Engn Dept, Sch Agr Food & Biosyst Engn, Madrid 28040, Spain
[2] Univ Politecn Madrid, Escuela Tecn Super Arquitectura, Dept Construct & Technol Architecture, Ave Juan de Herrera 4, Madrid 28040, Spain
来源
AGRONOMY-BASEL | 2021年 / 11卷 / 04期
关键词
wine; winery; aging; zero-energy building; cost; effectiveness; GROUND THERMAL INERTIA; PERFORMANCE ASSESSMENT; RENEWABLE ENERGY; EFFICIENCY; CONSUMPTION; BEHAVIOR; CELLARS; DESIGN; TEMPERATURE; SIMULATION;
D O I
10.3390/agronomy11040687
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
Achieving the best energy performance has become an important goal. The European Union has consequently developed legislative measures that introduce the concepts of nearly zero-energy buildings and cost-effectiveness during life-cycle. We use these concepts, looking for the design of energy-efficient wineries, while reducing wine production costs. The research method is based on the monitoring of temperature and humidity of 12 red wine aging rooms of representative construction designs with almost zero energy consumption that together with the economic data obtained from construction cost update, determine a parameter that has been called "construction effectiveness". This parameter allows the evaluation of the cost-benefit ratio of each of the analyzed constructions. The results obtained demonstrate that adequate conditions can be achieved for the wine aging with zero-energy buildings, although there are notable differences in cost, damping effectiveness, and resulting hygrothermal environment depending on the type of building. The correlation between performance and construction costs shows large differences in cost per unit of damping achieved: 0.5-2.7 euro/m(2) for temperature and 0.6-5 euro/m(2) for relative humidity. With a correct design, the differences between typologies can be reduced or even non-existent. The results obtained can be a valuable tool to promote the design of zero-energy warehouses.
引用
收藏
页数:16
相关论文
共 46 条
[1]   Multi-objective warehouse building design to optimize the cycle time, total cost, and carbon footprint [J].
Accorsi, Riccardo ;
Bortolini, Marco ;
Gamberi, Mauro ;
Manzini, Riccardo ;
Pilati, Francesco .
INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2017, 92 (1-4) :839-854
[2]   Energy end-use and efficiency potentials among Swedish industrial small and medium-sized enterprises - A dataset analysis from the national energy audit program [J].
Andersson, Elias ;
Karlsson, Magnus ;
Thollander, Patrik ;
Paramonova, Svetlana .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 93 :165-177
[3]  
[Anonymous], 2020, Design and Implementation of Virtual Campus System Based on Unity
[4]  
[Anonymous], 2018, 629741 AENOR EN
[5]   Designs for energy-efficient wine cellars (ageing rooms): a review [J].
Arredondo-Ruiz, F. ;
Canas, I. ;
Mazarron, F. R. ;
Manjarrez-Dominguez, C. B. .
AUSTRALIAN JOURNAL OF GRAPE AND WINE RESEARCH, 2020, 26 (01) :9-28
[6]   Towards net zero energy in industrial and commercial buildings in Portugal [J].
Bandeiras, F. ;
Gomes, M. ;
Coelho, P. ;
Fernandes, J. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2020, 119
[7]   Effect of various thermo-hygrometric conditions on the withering kinetics of grapes used for the production of "Amarone" and "Recioto" wines [J].
Barbanti, Davide ;
Mora, Beatrice ;
Ferrarini, Roberto ;
Tornielli, Giovanni B. ;
Cipriani, Michela .
JOURNAL OF FOOD ENGINEERING, 2008, 85 (03) :350-358
[8]   Retrofit interventions in non-conditioned rooms: calibration of an assessment method on a farm winery [J].
Barbaresi, Alberto ;
Dallacasa, Francesca ;
Torreggiani, Daniele ;
Tassinari, Patrizia .
JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2017, 10 (01) :91-104
[9]   Underground cellar thermal simulation: Definition of a method for modelling performance assessment based on experimental calibration [J].
Barbaresi, Alberto ;
Torreggiani, Daniele ;
Benni, Stefano ;
Tassinari, Patrizia .
ENERGY AND BUILDINGS, 2014, 76 :363-372
[10]   Historical development and environment adaptation of the traditional cave-dwellings in Tajuna's valley, Madrid, Spain [J].
Barbero-Barrera, M. M. ;
Gil-Crespo, I. J. ;
Maldonado-Ramos, L. .
BUILDING AND ENVIRONMENT, 2014, 82 :536-545