Quantitative image quality evaluation of an order-statistic filter in x-ray fluoroscopic imaging

被引:1
作者
Wilson, DL [1 ]
Srinivas, Y [1 ]
Sanchez-Marin, FJ [1 ]
Jabri, KN [1 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
来源
MEDICAL IMAGING 2000: IMAGE PERCEPTION AND PERFORMANCE | 2000年 / 3981卷
关键词
x-ray fluoroscopy; non-linear filters; image sequence filtering; image quality;
D O I
10.1117/12.383124
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of x-ray fluoroscopy in complex interventional procedures can result in high patient dose leading to severe skin injuries. Simply reducing exposure degrades image quality. One solution is to acquire images at reduced exposures and digitally filter to reduce noise and restore image quality. We quantitatively evaluated image quality improvement from a bidirectional multi-stage (BMS) median spatio-temporal filter. Improvements were assessed using forced-choice measurement of detection and discrimination. Targets were vertical projected cylinders mimicking interventional devices such as catheters. Poisson white noise was added on uniform backgrounds to simulate low-dose x-ray fluoroscopy. The EMS filter improved detection by 20% and discrimination by 31% giving estimated dose savings of 31% and 42%, respectively. Minimal spatial and temporal blurring of targets was observed in filtered sequences.
引用
收藏
页码:43 / 48
页数:6
相关论文
共 50 条
[41]   Radiation levels and image quality in patients undergoing chest X-ray examinations [J].
Campos de Oliveira, Paulo Marcio ;
Santana, Priscila do Carmo ;
de Sousa Lacerda, Marco Aurelio ;
da Silva, Teogenes Augusto .
RADIATION PHYSICS AND CHEMISTRY, 2017, 140 :305-308
[42]   Predicting Detection Performance on Security X-Ray Images as a Function of Image Quality [J].
Gupta, Praful ;
Sinno, Zeina ;
Glover, Jack L. ;
Paulter, Nicholas G., Jr. ;
Bovik, Alan C. .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2019, 28 (07) :3328-3342
[43]   Image quality characteristic of a novel X-ray detector with multiple screen - CCD sensors for real-time diagnostic imaging [J].
Slump, CH ;
Laanstra, GJ ;
Kuipers, H ;
Boer, MA ;
Nijmeijer, AGJ ;
Bentum, MJ ;
Kemner, R ;
Meulenbrugge, HJ ;
Snoeren, RM .
PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 :60-71
[44]   Image quality in digital phase contrast imaging using a tungsten anode X-ray tube with a small focal spot size [J].
Ohara, H ;
Honda, C ;
Ishisaka, A ;
Shimada, F .
MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 :713-723
[45]   An anthropomorphic beating heart phantom for cardiac X-ray CT imaging evaluation [J].
Boltz, Thomas ;
Pavlicek, William ;
Paden, Robert ;
Renno, Markus ;
Jensen, Angela ;
Akay, Metin .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (01) :191-199
[46]   3D Reconstruction of Coronary Veins from a Single X-Ray Fluoroscopic Image and Pre-operative MR [J].
Panayiotou, Maria ;
Toth, Daniel ;
Adem, Tamer ;
Mountney, Peter ;
Brost, Alexander ;
Behar, Jonathan M. ;
Rinaldi, C. Aldo ;
Housden, R. James ;
Rhode, Kawal S. .
STATISTICAL ATLASES AND COMPUTATIONAL MODELS OF THE HEART: IMAGING AND MODELLING CHALLENGES, 2016, 2017, 10124 :66-75
[47]   Do flat detector cardiac X-ray systems convey advantages over image-intensifier-based systems? Study comparing X-ray dose and image quality [J].
Davies, Andrew G. ;
Cowen, Arnold R. ;
Kengyelics, Stephen M. ;
Moore, Janet ;
Sivananthan, Mohan U. .
EUROPEAN RADIOLOGY, 2007, 17 (07) :1787-1794
[48]   Do flat detector cardiac X-ray systems convey advantages over image-intensifier-based systems? Study comparing X-ray dose and image quality [J].
Andrew G. Davies ;
Arnold R. Cowen ;
Stephen M. Kengyelics ;
Janet Moore ;
Mohan U. Sivananthan .
European Radiology, 2007, 17 :1787-1794
[49]   Image Quality optimization using an x-ray spectra model based optimization method [J].
Gordon, CL .
MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 :456-465
[50]   Experiments on radiographic image quality using low energy portable X-ray equipments [J].
Yabushita, N ;
Ooka, N ;
Nakamura, K .
ADVANCES IN NONDESTRUCTIVE EVALUATION, PT 1-3, 2004, 270-273 :1366-1370