Dose reduction in multislice computed tomography

被引:44
作者
Hundt, W
Rust, F
Stäbler, A
Wolff, H
Suess, C
Reiser, M
机构
[1] Univ Munich, Klinikum Grosshadern, Dept Clin Radiol, D-81377 Munich, Germany
[2] Siemens Med Solut, Erlangen, Germany
关键词
multislice computed tomography; dose reduction; image quality;
D O I
10.1097/01.rct.0000151188.72850.0d
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Evaluation of the attenuation-based on-line modulation of tube current on multislice computed tomography (CT) to explore the potential of this dose-saving technique. Methods: Fifty-five patients with follow-up CT examinations were scanned without and with a CARE Dose (Siemens Medical Solutions, Erlangen, Germany). The applied dose, image noise, and subjective image quality were evaluated. The reduction in patient exposure was determined by obtaining the effective milliamperes per second for each reconstructed scan and the absolute dosage requirement for the whole scan. Results: The dose reduction achieved by applying the attenuation-based on-line modulation of tube current was 29.4% +/- 3.1% (P = 0.002) for all scans, 30.5% +/- 3.2% (P = 0.002) for the thorax scans, 29.7% +/- 2.9% (P = 0.002) for the abdomen scans, and 28.7% +/- 2.7% (P = 0.003) for the thorax and abdomen scans together. No significant restrictions in image quality were observed. Conclusions: Remarkable dose reduction can be obtained using the attenuation-based on-line modulation of tube current on multislice CT without compromising image quality.
引用
收藏
页码:140 / 147
页数:8
相关论文
共 20 条
[1]   Current development of cardiac imaging with multidetector-row CT [J].
Becker, CR ;
Ohnesorge, BM ;
Schoepf, UJ ;
Reiser, MF .
EUROPEAN JOURNAL OF RADIOLOGY, 2000, 36 (02) :97-103
[2]  
FOLEY WD, 1994, RADIOLOGY, V193, P127
[3]  
Giacomuzzi S M, 1996, Aktuelle Radiol, V6, P110
[4]   The Smart-Scan-Technique in spiral computed tomography. A new method for dose reduction. [J].
Giacomuzzi, SM ;
Erckert, B ;
Schopf, T ;
Freund, MC ;
Springer, P ;
Dessl, A ;
Jaschke, W .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1996, 165 (01) :10-16
[5]   Dose reduction in CT by anatomically adapted tube current modulation. 1. Simulation studies [J].
Gies, M ;
Kalender, WA ;
Wolf, H ;
Suess, C ;
Madsen, MT .
MEDICAL PHYSICS, 1999, 26 (11) :2235-2247
[6]   Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions [J].
Greess, H ;
Wolf, H ;
Baum, U ;
Lell, M ;
Pirkl, M ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2000, 10 (02) :391-394
[7]  
GREESS H, 1998, ADV CT, V4, P35
[8]  
Greess HR, 2002, RADIOLOGY, V225, P593
[9]   Spiral CT and radiation dose [J].
Imhof, H ;
Schibany, N ;
Ba-Ssalamah, A ;
Czerny, C ;
Hojreh, A ;
Kainberger, F ;
Krestan, C ;
Kudler, H ;
Nöbauer, I ;
Nowotny, R .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 47 (01) :29-37
[10]   Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements [J].
Kalender, WA ;
Wolf, H ;
Suess, C .
MEDICAL PHYSICS, 1999, 26 (11) :2248-2253