VOLUMETRIC IMAGING BY MEGAVOLTAGE COMPUTED TOMOGRAPHY FOR ASSESSMENT OF INTERNAL ORGAN MOTION DURING RADIOTHERAPY FOR CERVICAL CANCER

被引:60
作者
Collen, Christine [1 ]
Engels, Benedikt [1 ]
Duchateau, Michael [1 ]
Tournel, Koen [1 ]
De Ridder, Mark [1 ]
Bral, Samuel [1 ]
Verellen, Dirk [1 ]
Storme, Guy [1 ]
机构
[1] UZ Brussel, Oncol Ctr Univ Hosp Brussels, Dept Radiotherapy, Brussels, Belgium
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2010年 / 77卷 / 05期
关键词
Cervical cancer; MVCT imaging; Organ motion; IMRT; Treatment margins; PROSTATE; CT;
D O I
10.1016/j.ijrobp.2009.10.021
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the internal organ motion of the cervix and uterus by megavoltage computed tomography (MVCT) during intensity-modulated radiotherapy (IMRT). Methods and Materials: Ten patients with Stage IIB IVA cervical cancer underwent daily MVCT imaging. Internal organ motion was evaluated on 150 pretreatment MVCT images by measuring shifts in their boundaries between the MVCT and kilovoltage (kV) planning CT scan in the anterior, posterior, left and right lateral, and superior and inferior direction. Additional intrafractional patient movement was evaluated on 50 posttreatment MVCT images. Results: Measured cervical motion (mean +/- SD) was 0.4 +/- 10.1 mm in the anterior, 3.0 +/- 6.9 mm in the posterior direction, 3.5 +/- 4.9 mm in the left and 0.2 +/- 4.5 mm in the right lateral direction, 2.2 +/- 8.0 mm in the superior and 0.5 +/- 5.0 mm in the inferior direction. Compared to the cervix, larger uterine motion was observed. Patient movement during treatment was limited to 1.1 +/- 1.3 mm, 0.3 +/- 1.6 mm, and 0.2 +/- 2.3 mm in anteroposterior, laterolateral and superoinferior direction respectively. Conclusions: MVCT imaging can be used to study patient setup accuracy and cervical and uterine motion during IMRT. This data may be used to refine treatment margins. (C) 2010 Elsevier Inc.
引用
收藏
页码:1590 / 1595
页数:6
相关论文
共 50 条
[41]   Diagnosis of Insufficiency Fracture After Radiotherapy in Patients With Cervical Cancer: Contribution of Technetium Tc99m -Labeled Methylene Diphosphonate Single-Photon Emission Computed Tomography/Computed Tomography [J].
Zhang, Linqi ;
He, Qiao ;
Jiang, Ming ;
Zhang, Bing ;
Zhong, Xi ;
Zhang, Rusen .
INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2018, 28 (07) :1369-1376
[42]   IMPACT OF FOUR-DIMENSIONAL COMPUTED TOMOGRAPHY PULMONARY VENTILATION IMAGING-BASED FUNCTIONAL AVOIDANCE FOR LUNG CANCER RADIOTHERAPY [J].
Yamamoto, Tokihiro ;
Kabus, Sven ;
von Berg, Jens ;
Lorenz, Cristian ;
Keall, Paul J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (01) :279-288
[43]   Setup errors in cone-beam computed tomography and their effects on acute radiation toxicity in cervical cancer radiotherapy [J].
Xin, S. .
GENETICS AND MOLECULAR RESEARCH, 2015, 14 (03) :10937-10943
[44]   Assessment of water enema computed tomography: an effective imaging technique for the diagnosis of colon cancer [J].
Ridereau-Zins, Catherine ;
Aube, Christophe ;
Luet, Dominique ;
Vielle, Bruno ;
Pilleul, Franck ;
Dumortier, Jerome ;
Gandon, Yves ;
Heresbach, Denis ;
Beziat, Christophe ;
Bailly, Francois ;
DeBilly, Marjolaine ;
Carbonnel, Franck ;
Pierredon-Foulongne, Marie Ange ;
Bismuth, Mickael ;
Chretien, Jean-Marie ;
Lebigot, Jerome ;
Pessaux, Patrick ;
Valette, Pierre-Jean .
ABDOMINAL IMAGING, 2010, 35 (04) :407-413
[45]   Evaluation of Inter-fraction Prostate Motion using Kilovoltage Cone Beam Computed Tomography during Radiotherapy [J].
Snir, J. A. ;
Battista, J. J. ;
Bauman, G. ;
Yartsev, S. .
CLINICAL ONCOLOGY, 2011, 23 (09) :625-631
[46]   ANALYSIS OF PROSTATE BED MOTION USING DAILY CONE-BEAM COMPUTED TOMOGRAPHY DURING POSTPROSTATECTOMY RADIOTHERAPY [J].
Ost, Piet ;
De Meerleer, Gert ;
De Gersem, Werner ;
Impens, Aline ;
De Neve, Wilfried .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (01) :188-194
[47]   Assessment of water enema computed tomography: an effective imaging technique for the diagnosis of colon cancerColon cancer: computed tomography using a water enema [J].
Catherine Ridereau-Zins ;
Christophe Aubé ;
Dominique Luet ;
Bruno Vielle ;
Franck Pilleul ;
Jérôme Dumortier ;
Yves Gandon ;
Denis Heresbach ;
Christophe Beziat ;
François Bailly ;
Marjolaine DeBilly ;
Franck Carbonnel ;
Marie Ange Pierredon-Foulongne ;
Mickaël Bismuth ;
Jean-Marie Chretien ;
Jérôme Lebigot ;
Patrick Pessaux ;
Pierre-Jean Valette .
Abdominal Imaging, 2010, 35 :407-413
[48]   Fan beam computed tomography-guided online adaptive external radiotherapy for cervical cancer achieves pathological complete response: A case report [J].
Peng, Haibo ;
Xu, Ningyue ;
Gao, Dong ;
Tan, Huigang ;
Ren, Tao .
ONCOLOGY LETTERS, 2025, 30 (01)
[49]   Set-Up Errors, Organ Motion, Tumour Regression and its Implications on Internal Target Volume-Planning Target Volume During Cervical Cancer Radiotherapy: Results From a Prospective Study [J].
Mahantshetty, U. ;
Naga, P. ;
Nachankar, A. ;
Ghadi, Y. ;
Dheera, A. ;
Scaria, L. ;
Epili, D. ;
Chopra, S. ;
Lavanya, G. ;
Shrivastava, S. .
CLINICAL ONCOLOGY, 2022, 34 (03) :189-197
[50]   Comparison of Computed Tomography and Magnetic Resonance Imaging in Cervical Cancer Brachytherapy Target and Normal Tissue Contouring [J].
Eskander, Ramez N. ;
Scanderbeg, Daniel ;
Saenz, Cheryl C. ;
Brown, Michelle ;
Yashar, Catherine .
INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2010, 20 (01) :47-53