VOLUMETRIC IMAGING BY MEGAVOLTAGE COMPUTED TOMOGRAPHY FOR ASSESSMENT OF INTERNAL ORGAN MOTION DURING RADIOTHERAPY FOR CERVICAL CANCER

被引:60
作者
Collen, Christine [1 ]
Engels, Benedikt [1 ]
Duchateau, Michael [1 ]
Tournel, Koen [1 ]
De Ridder, Mark [1 ]
Bral, Samuel [1 ]
Verellen, Dirk [1 ]
Storme, Guy [1 ]
机构
[1] UZ Brussel, Oncol Ctr Univ Hosp Brussels, Dept Radiotherapy, Brussels, Belgium
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2010年 / 77卷 / 05期
关键词
Cervical cancer; MVCT imaging; Organ motion; IMRT; Treatment margins; PROSTATE; CT;
D O I
10.1016/j.ijrobp.2009.10.021
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the internal organ motion of the cervix and uterus by megavoltage computed tomography (MVCT) during intensity-modulated radiotherapy (IMRT). Methods and Materials: Ten patients with Stage IIB IVA cervical cancer underwent daily MVCT imaging. Internal organ motion was evaluated on 150 pretreatment MVCT images by measuring shifts in their boundaries between the MVCT and kilovoltage (kV) planning CT scan in the anterior, posterior, left and right lateral, and superior and inferior direction. Additional intrafractional patient movement was evaluated on 50 posttreatment MVCT images. Results: Measured cervical motion (mean +/- SD) was 0.4 +/- 10.1 mm in the anterior, 3.0 +/- 6.9 mm in the posterior direction, 3.5 +/- 4.9 mm in the left and 0.2 +/- 4.5 mm in the right lateral direction, 2.2 +/- 8.0 mm in the superior and 0.5 +/- 5.0 mm in the inferior direction. Compared to the cervix, larger uterine motion was observed. Patient movement during treatment was limited to 1.1 +/- 1.3 mm, 0.3 +/- 1.6 mm, and 0.2 +/- 2.3 mm in anteroposterior, laterolateral and superoinferior direction respectively. Conclusions: MVCT imaging can be used to study patient setup accuracy and cervical and uterine motion during IMRT. This data may be used to refine treatment margins. (C) 2010 Elsevier Inc.
引用
收藏
页码:1590 / 1595
页数:6
相关论文
共 50 条
[1]   Cone beam computed tomography-based monitoring and management of target and organ motion during external beam radiotherapy in cervical cancer [J].
Jensen, Nina Boje Kibsgaard ;
Assenholt, Marianne Sanggaard ;
Fokdal, Lars Ulrik ;
Vestergaard, Anne ;
Schouboe, Annette ;
Kjaersgaard, Eva Bruun ;
Boejen, Annette ;
Nyvang, Lars ;
Lindegaard, Jacob Christian ;
Tanderup, Kari .
PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 9 :14-20
[2]   Pelvic target volume inter-fractional motion during radiotherapy for cervical cancer with daily iterative cone beam computed tomography [J].
Zeng, Zheng ;
Zhu, Jiawei ;
Wang, Zhiqun ;
Wang, Guangyu ;
Yan, Junfang ;
Zhang, Fuquan .
RADIATION ONCOLOGY, 2024, 19 (01)
[3]   Pelvic Organ Motion during Radiotherapy for Cervical Cancer: Understanding Patterns and Recommended Patient Preparation [J].
Eminowicz, G. ;
Motlib, J. ;
Khan, S. ;
Perna, C. ;
McCormack, M. .
CLINICAL ONCOLOGY, 2016, 28 (09) :E85-E91
[4]   INTERFRACTION AND RESPIRATORY ORGAN MOTION DURING CONFORMAL RADIOTHERAPY IN GASTRIC CANCER [J].
Wysocka, Barbara ;
Kassam, Zahra ;
Lockwood, Gina ;
Brierley, James ;
Dawson, Laura A. ;
Buckley, Carol Ann ;
Jaffray, David ;
Cummings, Bernard ;
Kim, John ;
Wong, Rebecca ;
Ringash, Jolie .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (01) :53-59
[5]   Pelvic target volume motion for cervical cancer with daily iterative cone beam computed tomography [J].
Zeng, Zheng ;
Zhang, Fuquan ;
Yan, Junfang .
RADIOTHERAPY AND ONCOLOGY, 2024, 197 :S139-S141
[6]   Analysis of inter-fraction setup errors and organ motion by daily kilovoltage cone beam computed tomography in intensity modulated radiotherapy of prostate cancer [J].
Palombarini, Marcella ;
Mengoli, Stefano ;
Fantazzini, Paola ;
Cadioli, Cecilia ;
Esposti, Claudio Degli ;
Frezza, Giovanni Piero .
RADIATION ONCOLOGY, 2012, 7
[7]   Changes in Tumor Volumes and Spatial Locations Relative to Normal Tissues During Cervical Cancer Radiotherapy Assessed by Cone Beam Computed Tomography [J].
Chen, Wenjuan ;
Bai, Penggang ;
Pan, Jianji ;
Xu, Yuanji ;
Chen, Kaiqiang .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (02) :246-252
[8]   A Systematic Review of Organ Motion and Image-guided Strategies in External Beam Radiotherapy for Cervical Cancer [J].
Jadon, R. ;
Pembroke, C. A. ;
Hanna, C. L. ;
Palaniappan, N. ;
Evans, M. ;
Cleves, A. E. ;
Staffurth, J. .
CLINICAL ONCOLOGY, 2014, 26 (04) :185-196
[9]   The using of megavoltage computed tomography in image-guided brachytherapy for cervical cancer: a case report [J].
Tharavichitkul, Ekkasit ;
Janla-or, Suwapim ;
Wanwilairat, Somsak ;
Chakrabandhu, Somvilai ;
Klunklin, Pitchayaponne ;
Onchan, Wimrak ;
Supawongwattana, Bongkot ;
Galalae, Razvan M. ;
Chitapanarux, Imjai .
RADIATION ONCOLOGY JOURNAL, 2015, 33 (02) :155-159
[10]   Diagnostic Imaging Performance of Dual-Energy Computed Tomography Compared with Conventional Computed Tomography and Magnetic Resonance Imaging for Uterine Cervical Cancer [J].
Shibuki, Saki ;
Saida, Tsukasa ;
Mori, Kensaku ;
Ishiguro, Toshitaka ;
Amano, Taishi ;
Yoshida, Miki ;
Miyata, Mariko ;
Satoh, Toyomi ;
Nakajima, Takahito .
INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2024, 34 (04) :661-669