Alternative to the median region of the palate for placement of an orthodontic implant

被引:118
作者
Bernhart, T
Vollgruber, A
Gahleitner, A
Dörtbudak, O
Haas, R
机构
[1] Univ Vienna, Dept Oral Surg, Sch Dent, A-1090 Vienna, Austria
[2] Univ Vienna, Gen Hosp Vienna, Dept Radiol Osteol & MR, Vienna, Austria
关键词
orthodontics; palatal implant; anchorage; computed tomography;
D O I
10.1034/j.1600-0501.2000.011006595.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Tooth-borne anchorage may be one of the greatest limitations of modern orthodontic treatment, because teeth move in response to forces. Previous investigators have placed temporary implants in the median-sagittal palate in order to establish maximum anchorage. This area, however, may be characterized by relatively low vertical bone support. The aim of this study was therefore to find an alternative palatal implant site which offers a higher amount of bone support. This study comprised 22 patients wishing for maximum anchorage underwent presurgical diagnostic evaluation by means of low-dose dental CT. The measuring results regarding vertical bone volume and the position of the neighbouring tooth roots were used as the basis for further treatment. The statistical data analysis indicated an area suitable for implant placement in the group of patients examined. This area was located 6 to 9 mm posterior to the incisive foramen and 3 to 6 mm paramedian, under avoidance of the mid-palatal suture. The patients showed such a great range of variation in vertical bone volume that a preoperative diagnostic evaluation also seems to be recommendable when very short implants are used in order to avoid perforations of the lower nasal duct.
引用
收藏
页码:595 / 601
页数:7
相关论文
共 30 条
  • [1] [Anonymous], 1992, INF ORTHOD KIEFEROR
  • [2] A NEW DEVICE FOR ABSOLUTE ANCHORAGE FOR ORTHODONTICS
    BLOCK, MS
    HOFFMAN, DR
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1995, 107 (03) : 251 - 258
  • [3] BOUSQUET F, 1996, J CLIN ORTHODONTICS, V5, P261
  • [4] CREEKMORE TD, 1983, J CLIN ORTHODONTICS, V54, P156
  • [5] Diederichs CG, 1996, AM J NEURORADIOL, V17, P1758
  • [6] Diedrich P, 1993, Fortschr Kieferorthop, V54, P156, DOI 10.1007/BF02171574
  • [7] FISHMAN LS, 1982, ANGLE ORTHOD, V52, P88
  • [8] Glatzmaier J, 1995, Fortschr Kieferorthop, V56, P175, DOI 10.1007/BF02276634
  • [9] Low-dose-Computertomographie des Kieferknochens in der präimplantologischen DiagnostikGrenzen der Dosisreduzierung und Genauigkeit von LängenmessungenLow-dose CT of the mandible and maxilla for dental implant treatment diagnosis: dose reduction limits and distance measurement precision
    S. Haßfeld
    S. Streib
    H. Sahl
    U. Stratmann
    D. Fehrentz
    J. Zöller
    [J]. Mund-, Kiefer- und Gesichtschirurgie, 1998, 2 (4): : 188 - 193
  • [10] HIGUCHI K W, 1991, International Journal of Oral and Maxillofacial Implants, V6, P338