Attenuation correction for cardiac dual-head γ camera coincidence imaging using segmented myocardial perfusion SPECT

被引:0
作者
Fukuchi, K
Sago, M
Nita, K
Fukushima, K
Toba, M
Hayashida, K
Takamiya, M
Ishida, Y
机构
[1] Natl Cardiovasc Ctr, Dept Radiol, Suita, Osaka 5658565, Japan
[2] Sumitomo Met Ind Ltd, Div Biomed, Tokyo, Japan
关键词
FDG; coincidence gamma camera imaging; PET; attenuation correction;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The diagnostic accuracy of cardiac FDG imaging obtained with the dual-head coincidence gamma camera (DHC) is impaired by artifacts induced by nonuniform attenuation. This study proposed a new method (registration and segmentation method for attenuation correction [AC-RS]) to correct these attenuations in the chest region without the need for additional hardware or expensive transmission scanning equipment. Methods: Before DHC imaging, Tc-99m-tetrofosmin SPECT was performed using dual-energy acquisition from both the photopeak and Compton scatter windows. The scatter window images of the Tc-99m-tetrofosmin were then registered 3-dimensionally with the cardiac DHC images and segmented into anatomic regions to obtain body and lung contours by applying the optimal threshold method on localized histograms. Theoretic attenuation coefficient Values were assigned to the corresponding anatomic regions, and the DHC emission images were reconstructed using these attenuation correction factors. The results were quantitatively evaluated by imaging a cardiac phantom filled with a uniform solution and placed in a chest phantom. Eight nondiabetic subjects were also examined using this technique, and the results were compared with those of measured attenuation-corrected PET images. Results: Use of this technique in phantom and clinical studies decreased the degree of artifacts seen in the inferior wall activity and corrected the emission images. When the results were compared with those of PET scans, the regional relative counts of the uncorrected DHC scan did not correlate with the results of the PET scan. However, the regional relative counts of the AG-RS-corrected DHC scan exhibited a linear correlation with the results of the PET scan (r = 0.73; P < 0.001), Conclusion: Reasonably accurate attenuation-corrected cardiac DHC images can be obtained using AC-RS without the need for transmission scanning.
引用
收藏
页码:919 / 925
页数:7
相关论文
共 50 条
  • [41] Attenuation correction for cardiac SPECT imaging using small field-of-view detectors
    Bai, Chuanyong
    Conwell, Richard
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2112 - 2116
  • [42] Usefulness of dual-head coincidence gamma camera with thick NaI crystals for nuclear oncology: Comparison with dedicated PET camera and conventional gamma camera with thin NaI crystals
    Inoue, T
    Oriuchi, N
    Koyama, K
    Ichikawa, A
    Tomiyoshi, K
    Sato, N
    Matsubara, K
    Suzuki, H
    Aoki, J
    Endo, K
    ANNALS OF NUCLEAR MEDICINE, 2001, 15 (02) : 141 - 148
  • [43] Value of attenuation correction on ECG-gated SPECT myocardial perfusion imaging related to body mass index
    Randall C. Thompson
    Gary V. Heller
    Lynne L. Johnson
    James A. Case
    S. James Cullom
    Ernest V. Garcia
    Philip G. Jones
    Kelly L. Moutray
    Timothy M. Bateman
    Journal of Nuclear Cardiology, 2005, 12 : 195 - 202
  • [44] Attenuation correction of myocardial SPECT perfusion images with low-dose CT: Evaluation of the method by comparison with perfusion PET
    Fricke, E
    Fricke, H
    Weise, R
    Kammeier, A
    Hagedorn, R
    Lotz, N
    Lindner, O
    Tschoepe, D
    Burchert, W
    JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (05) : 736 - 744
  • [45] Value of attenuation correction on ECG-gated SPECT myocardial perfusion imaging related to body mass index
    Thompson, RC
    Heller, GV
    Johnson, LL
    Case, JA
    Cullom, SJ
    Garcia, EV
    Jones, PG
    Moutray, KL
    Bateman, TM
    JOURNAL OF NUCLEAR CARDIOLOGY, 2005, 12 (02) : 195 - 202
  • [46] Impact of respiratory motion correction on SPECT myocardial perfusion imaging using a mechanically moving phantom assembly with variable cardiac defects
    Polycarpou, Irene
    Chrysanthou-Baustert, Isabelle
    Demetriadou, Ourania
    Parpottas, Yiannis
    Panagidis, Christoforos
    Marsden, Paul K.
    Livieratos, Lefteris
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (04) : 1216 - 1225
  • [47] Attenuation correction using deep learning for brain perfusion SPECT images
    Kenta Sakaguchi
    Hayato Kaida
    Shuhei Yoshida
    Kazunari Ishii
    Annals of Nuclear Medicine, 2021, 35 : 589 - 599
  • [48] Is Transmission-Gating Necessary for Cardiac SPECT Imaging with Attenuation Correction?
    Bai, Chuanyong
    Conwell, Richard
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2703 - 2709
  • [49] Attenuation correction using deep learning for brain perfusion SPECT images
    Sakaguchi, Kenta
    Kaida, Hayato
    Yoshida, Shuhei
    Ishii, Kazunari
    ANNALS OF NUCLEAR MEDICINE, 2021, 35 (05) : 589 - 599
  • [50] A comparison between upright and supine myocardial perfusion imaging with attenuation correction
    Tout, Deborah
    Tonge, Christine
    Austin, Peter
    Adams, Joanne
    Arumugam, Parthiban
    NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (08) : 832 - 838