Attenuation correction for cardiac dual-head γ camera coincidence imaging using segmented myocardial perfusion SPECT

被引:0
作者
Fukuchi, K
Sago, M
Nita, K
Fukushima, K
Toba, M
Hayashida, K
Takamiya, M
Ishida, Y
机构
[1] Natl Cardiovasc Ctr, Dept Radiol, Suita, Osaka 5658565, Japan
[2] Sumitomo Met Ind Ltd, Div Biomed, Tokyo, Japan
关键词
FDG; coincidence gamma camera imaging; PET; attenuation correction;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The diagnostic accuracy of cardiac FDG imaging obtained with the dual-head coincidence gamma camera (DHC) is impaired by artifacts induced by nonuniform attenuation. This study proposed a new method (registration and segmentation method for attenuation correction [AC-RS]) to correct these attenuations in the chest region without the need for additional hardware or expensive transmission scanning equipment. Methods: Before DHC imaging, Tc-99m-tetrofosmin SPECT was performed using dual-energy acquisition from both the photopeak and Compton scatter windows. The scatter window images of the Tc-99m-tetrofosmin were then registered 3-dimensionally with the cardiac DHC images and segmented into anatomic regions to obtain body and lung contours by applying the optimal threshold method on localized histograms. Theoretic attenuation coefficient Values were assigned to the corresponding anatomic regions, and the DHC emission images were reconstructed using these attenuation correction factors. The results were quantitatively evaluated by imaging a cardiac phantom filled with a uniform solution and placed in a chest phantom. Eight nondiabetic subjects were also examined using this technique, and the results were compared with those of measured attenuation-corrected PET images. Results: Use of this technique in phantom and clinical studies decreased the degree of artifacts seen in the inferior wall activity and corrected the emission images. When the results were compared with those of PET scans, the regional relative counts of the uncorrected DHC scan did not correlate with the results of the PET scan. However, the regional relative counts of the AG-RS-corrected DHC scan exhibited a linear correlation with the results of the PET scan (r = 0.73; P < 0.001), Conclusion: Reasonably accurate attenuation-corrected cardiac DHC images can be obtained using AC-RS without the need for transmission scanning.
引用
收藏
页码:919 / 925
页数:7
相关论文
共 50 条
  • [31] Initial experience with X-ray CT based attenuation correction in myocardial perfusion SPECT imaging using a combined SPECT/CT system
    Utsunomiya, D
    Tomiguchi, S
    Shiraishi, S
    Yamada, K
    Honda, T
    Kawanaka, K
    Kojima, A
    Awai, K
    Yamashita, Y
    ANNALS OF NUCLEAR MEDICINE, 2005, 19 (06) : 485 - 489
  • [32] Quantitative diagnostic performance of myocardial perfusion SPECT with attenuation correction in women
    Wolak, Arik
    Slomka, Piotr J.
    Fish, Mathews B.
    Lorenzo, Santiago
    Berman, Daniel S.
    Germano, Guido
    JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (06) : 915 - 922
  • [33] CT-based attenuation and scatter correction compared with uniform attenuation correction in brain perfusion SPECT imaging for dementia
    Gillen, Rebecca
    Firbank, Michael J.
    Lloyd, Jim
    O'Brien, John T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (17) : 6775 - 6787
  • [34] Comparison of dual-head coincidence gamma camera FDG imaging with FDG PET in detection of breast cancer and axillary lymph node metastasis
    Yutani, K
    Tatsumi, M
    Shiba, E
    Kusuoka, H
    Nishimura, T
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (06) : 1003 - 1008
  • [35] Usefulness of dual-head coincidence gamma camera with thick nal crystals for nuclear oncology: Comparison with dedicated PET camera and conventional gamma camera with thin NaI crystals
    Tomio Inoue
    Noboru Oriuchi
    Keiko Koyama
    Akihiro Ichikawa
    Katsumi Tomiyoshi
    Noriko Sato
    Kunio Matsubara
    Hideki Suzuki
    Jun Aoki
    Keigo Endo
    Annals of Nuclear Medicine, 2001, 15 : 141 - 148
  • [36] Attenuation correction and gating synergistically improve the diagnostic accuracy of myocardial perfusion SPECT
    Links, JM
    DePuey, EG
    Taillefer, R
    Becker, LC
    JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (02) : 183 - 187
  • [37] Evaluation of an adrenal mass in a patient with lung cancer by FDG coincidence positron emission tomography using a dual-head gamma camera
    Pai, MS
    Park, CH
    Yoon, SN
    Kim, S
    Whang, KH
    CLINICAL NUCLEAR MEDICINE, 2000, 25 (11) : 924 - 925
  • [38] Evaluation of the attenuation correction on myocardial perfusion imaging: a phantom study
    Machado, Marisa
    Oliveira, Francisco P. M.
    Vieira, Lina
    Costa, Durval C.
    2019 6TH IEEE PORTUGUESE MEETING IN BIOENGINEERING (ENBENG), 2019,
  • [39] Attenuation correction and gating synergistically improve the diagnostic accuracy of myocardial perfusion SPECT
    Jonathan M. Links
    E. Gordon DePuey
    Raymond Taillefer
    Lewis C. Becker
    Journal of Nuclear Cardiology, 2002, 9 : 183 - 187
  • [40] Attenuation correction in myocardial perfusion SPECT/CT: Effects of misregistration and value of reregistration
    Goetze, Sibyll
    Brown, Tracy L.
    Lavely, William C.
    Zhang, Zhe
    Bengel, Frank M.
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (07) : 1090 - 1095