Attenuation correction for cardiac dual-head γ camera coincidence imaging using segmented myocardial perfusion SPECT

被引:0
作者
Fukuchi, K
Sago, M
Nita, K
Fukushima, K
Toba, M
Hayashida, K
Takamiya, M
Ishida, Y
机构
[1] Natl Cardiovasc Ctr, Dept Radiol, Suita, Osaka 5658565, Japan
[2] Sumitomo Met Ind Ltd, Div Biomed, Tokyo, Japan
关键词
FDG; coincidence gamma camera imaging; PET; attenuation correction;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The diagnostic accuracy of cardiac FDG imaging obtained with the dual-head coincidence gamma camera (DHC) is impaired by artifacts induced by nonuniform attenuation. This study proposed a new method (registration and segmentation method for attenuation correction [AC-RS]) to correct these attenuations in the chest region without the need for additional hardware or expensive transmission scanning equipment. Methods: Before DHC imaging, Tc-99m-tetrofosmin SPECT was performed using dual-energy acquisition from both the photopeak and Compton scatter windows. The scatter window images of the Tc-99m-tetrofosmin were then registered 3-dimensionally with the cardiac DHC images and segmented into anatomic regions to obtain body and lung contours by applying the optimal threshold method on localized histograms. Theoretic attenuation coefficient Values were assigned to the corresponding anatomic regions, and the DHC emission images were reconstructed using these attenuation correction factors. The results were quantitatively evaluated by imaging a cardiac phantom filled with a uniform solution and placed in a chest phantom. Eight nondiabetic subjects were also examined using this technique, and the results were compared with those of measured attenuation-corrected PET images. Results: Use of this technique in phantom and clinical studies decreased the degree of artifacts seen in the inferior wall activity and corrected the emission images. When the results were compared with those of PET scans, the regional relative counts of the uncorrected DHC scan did not correlate with the results of the PET scan. However, the regional relative counts of the AG-RS-corrected DHC scan exhibited a linear correlation with the results of the PET scan (r = 0.73; P < 0.001), Conclusion: Reasonably accurate attenuation-corrected cardiac DHC images can be obtained using AC-RS without the need for transmission scanning.
引用
收藏
页码:919 / 925
页数:7
相关论文
共 50 条
  • [21] Clinical Utility of CT-based Attenuation-correction in Myocardial Perfusion SPECT Imaging
    Hatipoglu, Filiz
    Cetin, Neslihan
    MOLECULAR IMAGING AND RADIONUCLIDE THERAPY, 2023, 32 (02) : 138 - 145
  • [22] Deep learning approach using SPECT-to-PET translation for attenuation correction in CT-less myocardial perfusion SPECT imaging
    Masateru Kawakubo
    Michinobu Nagao
    Yoko Kaimoto
    Risako Nakao
    Atsushi Yamamoto
    Hiroshi Kawasaki
    Takafumi Iwaguchi
    Yuka Matsuo
    Koichiro Kaneko
    Akiko Sakai
    Shuji Sakai
    Annals of Nuclear Medicine, 2024, 38 : 199 - 209
  • [23] On the Effect of the Patient Table on Attenuation in Myocardial Perfusion Imaging SPECT
    Huxohl, Tamino
    Patel, Gopesh
    Burchert, Wolfgang
    EJNMMI PHYSICS, 2025, 12 (01):
  • [24] Fluorine-18-FDG detection of laryngeal cancer postradiotherapy using dual-head coincidence imaging
    Stokkel, MP
    Terhaard, CH
    Mertens, IJ
    Hordijk, GJ
    van Rijk, PP
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (08) : 1385 - 1387
  • [25] Dual-head coincidence γ camera;: 18F-FDG and 99mTc imagings
    Inoue, T
    Koyama, K
    Aoki, J
    Endo, K
    POSITRON EMISSION TOMOGRAPHY IN THE MILLENNIUM, 2000, 1197 : 171 - 177
  • [26] Assessment of malignancy in pulmonary lesions: FDG dual-head coincidence gamma camera imaging in association with serum tumor marker measurement
    Bousson, V
    Moretti, JL
    Weinmann, P
    Safi, N
    Tamgac, F
    Groiselle, C
    de Beco, V
    Hillali, Y
    Valeyre, D
    Breau, JL
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (11) : 1801 - 1807
  • [27] Transmission imaging for nonuniform attenuation correction using a three-headed SPECT camera
    Gilland, DR
    Jaszczak, RJ
    Greer, KL
    Coleman, RE
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (06) : 1105 - 1110
  • [28] Direct Image-Based Attenuation Correction using Conditional Generative Adversarial Network for SPECT Myocardial Perfusion Imaging
    Torkaman, Mahsa
    Yang, Jaewon
    Shi, Luyao
    Wang, Rui
    Miller, Edward J.
    Sinusas, Albert J.
    Liu, Chi
    Gullberg, Grant T.
    Seo, Youngho
    MEDICAL IMAGING 2021: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11600
  • [29] Respiratory average CT for attenuation correction in myocardial perfusion SPECT/CT
    Zhang, Duo
    Yang, Bang-Hung
    Wu, Nien Yun
    Mok, Greta Seng Peng
    ANNALS OF NUCLEAR MEDICINE, 2017, 31 (02) : 172 - 180
  • [30] Respiratory average CT for attenuation correction in myocardial perfusion SPECT/CT
    Duo Zhang
    Bang-Hung Yang
    Nien Yun Wu
    Greta Seng Peng Mok
    Annals of Nuclear Medicine, 2017, 31 : 172 - 180