Quantifying lateral penumbra advantages of collimated spot-scanning beam for intensity-modulated proton therapy

被引:4
|
作者
Liu, Chun-Bo [1 ]
Song, Yun-Tao [1 ,2 ]
Liu, Hong-Dong [1 ]
Xue, Hai-Zhou [3 ]
Feng, Han-Sheng [2 ]
机构
[1] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
[2] Chinese Acad Sci, Hefei Inst Phys Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
[3] Hefei CAS Ion Med & Tech Devices Co Ltd, Hefei 230088, Anhui, Peoples R China
关键词
Lateral penumbra; Patient-specific block collimator; Monte Carlo; Intensity-modulated proton therapy; DOSE-EQUIVALENT EXPOSURES; MONTE-CARLO; SIMULATION; QUALITY; DEPTH;
D O I
10.1007/s41365-019-0687-y
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Intensity-modulated proton therapy (IMPT) is becoming essential for proton therapy and is under rapid development. However, for IMPT, the lateral penumbra of the spot-scanning proton beam is still an urgent issue to be solved. Patient-specific block collimators (PSBCs), which can block unnecessary doses, play a crucial role in passive scattering delivery technology but are rarely used in spot scanning. One objective of this study is to investigate the lateral penumbra variations of intensity-modulated spot scanning with and without a PSBC. For fields with varying degrees of sharpness and at varying depths in a water phantom, the lateral penumbral widths were calculated using a Monte Carlo-based dose engine from RayStation 6. The results suggest that the lateral penumbral widths can be reduced by more than 30% for uniform target volumes, regardless of whether a range-shifter is used, and that the maximum dose beyond the field edges can be reduced significantly. The results of patient cases show that the doses in organs-at-risk near the edge of the target volume decrease if a PSBC is implemented. This study demonstrates that intensity-modulated spot scanning with a PSBC can effectively reduce the lateral penumbra and block unnecessary doses and is therefore promising for clinical applications in spot-scanning proton therapy.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Robust intensity-modulated proton therapy to reduce high linear energy transfer in organs at risk
    An, Yu
    Shan, Jie
    Patel, Samir H.
    Wong, William
    Schild, Steven E.
    Ding, Xiaoning
    Bues, Martin
    Liu, Wei
    MEDICAL PHYSICS, 2017, 44 (12) : 6138 - 6147
  • [42] Spot-scanning proton therapy for targets with adjacent cardiac implantable electronic devices - Strategies for breast and head & neck cancer
    Stick, Line Bjerregaard
    Laegdsmand, Peter Magnus Trock
    Bjerre, Henrik Laurits
    Hoyer, Morten
    Jensen, Kenneth
    Jensen, Maria Fuglsang
    Kronborg, Mads Brix
    Offersen, Birgitte Vrou
    Kronborg, Camilla Jensenius Skovhus
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 21 : 66 - 71
  • [43] Developing an accurate model of spot-scanning treatment delivery time and sequence for a compact superconducting synchrocyclotron proton therapy system
    Zhao, Lewei
    Liu, Gang
    Chen, Shupeng
    Shen, Jiajian
    Zheng, Weili
    Qin, An
    Yan, Di
    Li, Xiaoqiang
    Ding, Xuanfeng
    RADIATION ONCOLOGY, 2022, 17 (01)
  • [44] Explore the feasibility of using spot-scanning proton arc therapy for a synchrotron accelerator-based proton therapy system - A simulation study
    Cong, Xiaoda
    Liu, Gang
    Liu, Peilin
    Zhao, Lewei
    Chen, Shupeng
    Li, Xiaoqiang
    Shen, Jiajian
    Ding, Xuanfeng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (01):
  • [45] Motion-robust intensity-modulated proton therapy for distal esophageal cancer
    Yu, Jen
    Zhang, Xiaodong
    Liao, Li
    Li, Heng
    Zhu, Ronald
    Park, Peter C.
    Sahoo, Narayan
    Gillin, Michael
    Li, Yupeng
    Chang, Joe Y.
    Komaki, Ritsuko
    Lin, Steven H.
    MEDICAL PHYSICS, 2016, 43 (03) : 1111 - 1118
  • [46] Intensity-modulated proton therapy for oropharyngeal cancer reduces rates of late xerostomia
    Cao, Jianzhong
    Zhang, Xiaodong
    Jiang, Bo
    Chen, Jiayun
    Wang, Xiaochun
    Wang, Li
    Sahoo, Narayan
    Zhu, X. Ronald
    Ye, Rong
    Blanchard, Pierre
    Garden, Adam S.
    Fuller, C. David
    Gunn, G. Brandon
    Frank, Steven J.
    RADIOTHERAPY AND ONCOLOGY, 2021, 160 : 32 - 39
  • [47] USING A REDUCED SPOT SIZE FOR INTENSITY-MODULATED PROTON THERAPY POTENTIALLY IMPROVES SALIVARY GLAND-SPARING IN OROPHARYNGEAL CANCER
    van de Water, Tara A.
    Lomax, Antony J.
    Bijl, Hendrik P.
    Schilstra, Cornelis
    Hug, Eugen B.
    Langendijk, Johannes A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (12): : E313 - E319
  • [48] An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle
    Sawakuchi, Gabriel O.
    Mirkovic, Dragan
    Perles, Luis A.
    Sahoo, Narayan
    Zhu, X. Ron
    Ciangaru, George
    Suzuki, Kazumichi
    Gillin, Michael T.
    Mohan, Radhe
    Titt, Uwe
    MEDICAL PHYSICS, 2010, 37 (09) : 4960 - 4970
  • [49] Experimental validation of LET in intensity-modulated proton therapy with a miniaturized pixel detector
    Stasica-Dudek, Paulina
    Granja, Carlos
    Kopec, Renata
    Krzempek, Dawid
    Oancea, Cristina
    Rucinski, Antoni
    Rydygier, Marzena
    Winiarz, Mateusz
    Gajewski, Jan
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (09)
  • [50] Feasibility study of range-based registration using daily cone beam CT for intensity-modulated proton therapy
    Yao, Weiguang
    Krasin, Matthew J.
    Farr, Jonathan B.
    Merchant, Thomas E.
    MEDICAL PHYSICS, 2018, 45 (03) : 1191 - 1203