Quantifying lateral penumbra advantages of collimated spot-scanning beam for intensity-modulated proton therapy

被引:4
|
作者
Liu, Chun-Bo [1 ]
Song, Yun-Tao [1 ,2 ]
Liu, Hong-Dong [1 ]
Xue, Hai-Zhou [3 ]
Feng, Han-Sheng [2 ]
机构
[1] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
[2] Chinese Acad Sci, Hefei Inst Phys Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
[3] Hefei CAS Ion Med & Tech Devices Co Ltd, Hefei 230088, Anhui, Peoples R China
关键词
Lateral penumbra; Patient-specific block collimator; Monte Carlo; Intensity-modulated proton therapy; DOSE-EQUIVALENT EXPOSURES; MONTE-CARLO; SIMULATION; QUALITY; DEPTH;
D O I
10.1007/s41365-019-0687-y
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Intensity-modulated proton therapy (IMPT) is becoming essential for proton therapy and is under rapid development. However, for IMPT, the lateral penumbra of the spot-scanning proton beam is still an urgent issue to be solved. Patient-specific block collimators (PSBCs), which can block unnecessary doses, play a crucial role in passive scattering delivery technology but are rarely used in spot scanning. One objective of this study is to investigate the lateral penumbra variations of intensity-modulated spot scanning with and without a PSBC. For fields with varying degrees of sharpness and at varying depths in a water phantom, the lateral penumbral widths were calculated using a Monte Carlo-based dose engine from RayStation 6. The results suggest that the lateral penumbral widths can be reduced by more than 30% for uniform target volumes, regardless of whether a range-shifter is used, and that the maximum dose beyond the field edges can be reduced significantly. The results of patient cases show that the doses in organs-at-risk near the edge of the target volume decrease if a PSBC is implemented. This study demonstrates that intensity-modulated spot scanning with a PSBC can effectively reduce the lateral penumbra and block unnecessary doses and is therefore promising for clinical applications in spot-scanning proton therapy.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Quantifying lateral penumbra advantages of collimated spot-scanning beam for intensity-modulated proton therapy
    Chun-Bo Liu
    Yun-Tao Song
    Hong-Dong Liu
    Hai-Zhou Xue
    Han-Sheng Feng
    Nuclear Science and Techniques, 2019, 30 (11) : 54 - 61
  • [2] Quantifying lateral penumbra advantages of collimated spot-scanning beam for intensity-modulated proton therapy
    Chun-Bo Liu
    Yun-Tao Song
    Hong-Dong Liu
    Hai-Zhou Xue
    Han-Sheng Feng
    Nuclear Science and Techniques, 2019, 30
  • [3] Parametric characterization of penumbra reduction for aperture-collimated pencil beam scanning (PBS) proton therapy
    Maes, Dominic
    Regmi, Rajesh
    Taddei, Phillip
    Bloch, Charles
    Bowen, Steven
    Nevitt, Alexander
    Leuro, Erick
    Wong, Tony
    Rosenfeld, Anatoly
    Saini, Jatinder
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (03):
  • [4] Optimal minimum MU for intensity-modulated proton therapy with pencil-beam scanning proton beams
    Yi, Byongyong
    Mossahebi, Sina
    Jatczak, Jenna
    Mundis, Michelle
    Houser, Thomas
    Alicia, David
    Han, Dong
    Gonzalez, Rosette
    Olis, Stephen
    Zakhary, Mark
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (09):
  • [5] A method to select aperture margin in collimated spot scanning proton therapy
    Wang, Dongxu
    Smith, Blake R.
    Gelover, Edgar
    Flynn, Ryan T.
    Hyer, Daniel E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (07) : N109 - N119
  • [6] Effects of spot size and spot spacing on lateral penumbra reduction when using a dynamic collimation system for spot scanning proton therapy
    Hyer, Daniel E.
    Hill, Patrick M.
    Wang, Dongxu
    Smith, Blake R.
    Flynn, Ryan T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22) : N187 - N196
  • [7] Adjuvant intensity-modulated proton therapy in malignant pleural mesothelioma A comparison with intensity-modulated radiotherapy and a spot size variation assessment
    Lorentini, S.
    Amichetti, M.
    Spiazzi, L.
    Tonoli, S.
    Magrini, S. M.
    Fellin, F.
    Schwarz, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (03) : 216 - 225
  • [8] Robust optimization for intensity-modulated proton therapy with soft spot sensitivity regularization
    Gu, Wenbo
    Ruan, Dan
    O'Connor, Daniel
    Zou, Wei
    Dong, Lei
    Tsai, Min-Yu
    Jia, Xun
    Sheng, Ke
    MEDICAL PHYSICS, 2019, 46 (03) : 1408 - 1425
  • [9] Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Yu, Jen
    Gutierrez, Alonso N.
    Hill, Patrick M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (05)
  • [10] Biophysical characterization of collimated and uncollimated fields in pencil beam scanning proton therapy
    Nabha, Racell
    De Saint-Hubert, Marijke
    Marichal, Joachim
    Esser, Johannes
    Van Hoey, Olivier
    Baeumer, Christian
    Verbeek, Nico
    Struelens, Lara
    Sterpin, Edmond
    Tabury, Kevin
    Marek, Lukas
    Granja, Carlos
    Timmermann, Beate
    Vanhavere, Filip
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (06)