Impact of Direct Transcatheter Aortic Valve Replacement Without Balloon Aortic Valvuloplasty on Procedural and Clinical Outcomes Insights From the FRANCE TAVI Registry

被引:34
作者
Deharo, Pierre [1 ,2 ,3 ]
Jaussaud, Nicolas [4 ]
Grisoli, Dominique [4 ]
Camus, Olivier [5 ]
Resseguier, Noemie [6 ]
Le Breton, Herve [7 ]
Auffret, Vincent [7 ]
Verhoye, Jean Philippe [8 ]
Koning, Rene [9 ]
Lefevre, Thierry [10 ]
Van Belle, Eric [11 ]
Eltchaninoff, Helene [12 ]
Gilard, Martine [13 ]
Leprince, Pascal [14 ]
Lung, Bernard [15 ,16 ]
Lambert, Marc [1 ,3 ]
Collart, Frederic [3 ,4 ]
Cuisset, Thomas [1 ,3 ,17 ]
机构
[1] CHU Timone, Dept Cardiol, Marseille, France
[2] Aix Marseille Univ, UMR MD2, Marseille, France
[3] Aix Marseille Univ, Fac Med, Marseille, France
[4] CHU Timone, Serv Chirurg Cardiaque, Marseille, France
[5] Hop Instruct Armees Laveran, Marseille, France
[6] Aix Marseille Univ, Dept Publ Hlth, Res Unit EA 3279, Marseille, France
[7] Univ Rennes, CHU Rennes, Serv Cardiol, INSERM,Signal & Image Treatment Lab,U1099, Rennes, France
[8] Univ Rennes 1, Pontchaillou Univ Hosp Ctr, Natl Inst Hlth & Med Res U1099, Thorac & Cardiovasc Surg Serv,Signal & Image Trea, Rennes, France
[9] St Hilaire Clin, Cardiol Serv, Rouen, France
[10] Jacques Cartier Private Hosp, Paris South Cardiovasc Inst, Massy, France
[11] Univ Lille 2, Reg Univ Hosp Ctr Lille, Natl Inst Hlth & Med Res U1011, Univ Hosp Federat Integra,Dept Cardiol, Lille, France
[12] Rouen Charles Nicolle Univ Hosp Ctr, Natl Inst Hlth & Med Res U644, Cardiol Serv, Rouen, France
[13] Univ Western Brittany, La Cavale Blanche Univ Hosp Ctr, Dept Cardiol, Optimizat Physiol Regulat Sci & Tech Training & R, Brest, France
[14] Sorbonne Pierre & Marie Curie Univ, Grp Hosp Pitie Salpetriere, AP HP, Cardiac Surg, Paris, France
[15] Univ Hosp Dept Fire, Dept Cardiol, Paris, France
[16] Paris Diderot Univ, Bichat Hosp, AP HP, Paris, France
[17] Aix Marseille Univ, C2VN, Inra, Inserm, Marseille, France
关键词
aortic regurgitation; balloon aortic valvuloplasty; transcatheter aortic valve replacement; HIGH-RISK; IMPLANTATION; PREDILATATION; FEASIBILITY; REGURGITATION; METAANALYSIS; DILATION; SAFETY;
D O I
10.1016/j.jcin.2018.06.023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to describe the current practices and compare outcomes according to the use of balloon aortic valvuloplasty (BAV) or not during transcatheter aortic valve replacement (TAVR). BACKGROUND Since its development, aortic valve pre-dilatation has been an essential step of TAVR procedures. However, the feasibility of TAVR without systematic BAV has been described. METHODS TAVR performed in 48 centers across France between January 2013 and December 2015 were prospectively included in the FRANCE TAVI (Registry of Aortic Valve Bioprostheses Established by Catheter) registry. We compared outcomes according to BAV during the TAVR procedure. RESULTS A total of 5,784 patients have been included in our analysis, corresponding to 2,579 (44.6%) with BAV avoidance and 3,205 (55.4%) patients with BAV performed. We observed a progressive decline in the use of BAV over time (78% of procedures in 2013 and 49% in the last trimester of 2015). Avoidance of BAV was associated with similar device implantation success (97.3% vs. 97.6%; p 0.40). TAVR procedures without BAV were quicker (fluoroscopy 17.2 +/- 9.1 vs. 18.5 +/- 8.8 min; p < 0.01) and used tower amounts of contrast (131.5 +/- 61.6 vs. 141.6 +/- 61.5; p < 0.01) and radiation (608.9 +/- 576.3 vs. 667.0 +/- 631.3; p < 0.01). The rates of moderate to severe aortic regurgitation were tower with avoidance of BAV (8.3% vs. 12.2%; p < 0.01) and tamponade rates (1.5% vs. 2.3%; p 0.04). CONCLUSIONS We confirmed that TAVR without BAV is frequently performed in France with good procedural results. This procedure is associated with procedural simplification and tower rates of residual aortic regurgitation. (C) 2018 the American College of Cardiology Foundation. Published by Elsevier. All rights reserved.
引用
收藏
页码:1956 / 1965
页数:10
相关论文
共 24 条
[1]   Can predilatation in transcatheter aortic valve implantation be omitted? - a prospective randomized study [J].
Ahn, Henrik Casimir ;
Nielsen, Niels-Erik ;
Baranowski, Jacek .
JOURNAL OF CARDIOTHORACIC SURGERY, 2016, 11
[2]   Incidence, Predictors, and Outcomes of Aortic Regurgitation After Transcatheter Aortic Valve Replacement Meta-Analysis and Systematic Review of Literature [J].
Athappan, Ganesh ;
Patvardhan, Eshan ;
Tuzcu, E. Murat ;
Svensson, Lars Georg ;
Lemos, Pedro A. ;
Fraccaro, Chiara ;
Tarantini, Giuseppe ;
Sinning, Jan-Malte ;
Nickenig, Georg ;
Capodanno, Davide ;
Tamburino, Corrado ;
Latib, Azeem ;
Colombo, Antonio ;
Kapadia, Samir R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (15) :1585-1595
[3]   Feasibility, Safety, and Efficacy of Transcatheter Aortic Valve Replacement Without Balloon Predilation: A Systematic Review and Meta-Analysis [J].
Auffret, Vincent ;
Regueiro, Ander ;
Campelo-Parada, Francisco ;
del Trigo, Maria ;
Chiche, Olivier ;
Chamandi, Chekrallah ;
Puri, Rishi ;
Rodes-Cabau, Josep .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (05) :839-850
[4]   Temporal Trends in Transcatheter Aortic Valve Replacement in France FRANCE 2 to FRANCE TAVI [J].
Auffret, Vincent ;
Lefevre, Thierry ;
Van Belle, Eric ;
Eltchaninoff, Helene ;
Iung, Bernard ;
Koning, Rene ;
Motreff, Pascal ;
Leprince, Pascal ;
Verhoye, Jean Philippe ;
Manigold, Thibaut ;
Souteyrand, Geraud ;
Boulmier, Dominique ;
Joly, Patrick ;
Pinaud, Frederic ;
Himbert, Dominique ;
Collet, Jean Philippe ;
Rioufol, Gilles ;
Ghostine, Said ;
Bar, Olivier ;
Dibie, Alain ;
Champagnac, Didier ;
Leroux, Lionel ;
Collet, Frederic ;
Teiger, Emmanuel ;
Darremont, Olivier ;
Folliguet, Thierry ;
Leclercq, Florence ;
Lhermusier, Thibault ;
Olhmann, Patrick ;
Huret, Bruno ;
Lorgis, Luc ;
Drogoul, Laurent ;
Bertrand, Bernard ;
Spaulding, Christian ;
Quilliet, Laurent ;
Cuisset, Thomas ;
Delomez, Maxence ;
Beygui, Farzin ;
Claudel, Jean-Philippe ;
Hepp, Alain ;
Jegou, Arnaud ;
Gommeaux, Antoine ;
Mirode, Anfani ;
Christiaens, Luc ;
Christophe, Charles ;
Cassat, Claude ;
Metz, Damien ;
Mangin, Lionel ;
Isaaz, Karl ;
Jacquemin, Laurent .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (01) :42-55
[5]  
Baumgartner H, 2018, EUR HEART J, V39, P1980, DOI [10.1093/eurheartj/ehx636, 10.1093/eurheartj/ehx391]
[6]   Complications and Outcome of Balloon Aortic Valvuloplasty in High-Risk or Inoperable Patients [J].
Ben-Dor, Itsik ;
Pichard, Augusto D. ;
Satler, Lowell F. ;
Goldstein, Steven A. ;
Syed, Asmir I. ;
Gaglia, Michael A., Jr. ;
Weissman, Gaby ;
Maluenda, Gabriel ;
Gonzalez, Manuel A. ;
Wakabayashi, Kohei ;
Collins, Sara D. ;
Torguson, Rebecca ;
Okubagzi, Petros ;
Xue, Zhenyi ;
Kent, Kenneth M. ;
Lindsay, Joseph ;
Waksman, Ron .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (11) :1150-1156
[7]   Increased Risk of Cerebral Embolization After Implantation of a Balloon-Expandable Aortic Valve Without Prior Balloon Valvuloplasty [J].
Bijuklic, Klaudija ;
Haselbach, Timo ;
Witt, Julian ;
Krause, Korff ;
Hansen, Lorenz ;
Gehrckens, Ralf ;
Riess, Friedrich-Christian ;
Schofer, Joachim .
JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (12) :1608-1613
[8]   Transfemoral TAVI without pre-dilatation using balloon-expandable devices: a case-matched analysis [J].
Conradi, Lenard ;
Schaefer, Andreas ;
Seiffert, Moritz ;
Schirmer, Johannes ;
Schaefer, Ulrich ;
Schoen, Gerhard ;
Blankenberg, Stefan ;
Reichenspurner, Hermann ;
Treede, Hendrik ;
Diemert, Patrick .
CLINICAL RESEARCH IN CARDIOLOGY, 2015, 104 (09) :735-742
[9]   Transapical transcatheter aortic valve implantation without prior balloon aortic valvuloplasty: feasible and safeaEuro [J].
Conradi, Lenard ;
Seiffert, Moritz ;
Schirmer, Johannes ;
Koschyk, Dietmar ;
Blankenberg, Stefan ;
Reichenspurner, Hermann ;
Diemert, Patrick ;
Treede, Hendrik .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2014, 46 (01) :61-66
[10]   Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description [J].
Cribier, A ;
Eltchaninoff, H ;
Bash, A ;
Borenstein, N ;
Tron, C ;
Bauer, F ;
Derumeaux, G ;
Anselme, F ;
Laborde, F ;
Leon, MB .
CIRCULATION, 2002, 106 (24) :3006-3008