Pulmonary nodules: Effect on detection of spiral CT pitch

被引:33
|
作者
Wright, AR [1 ]
Collie, DA [1 ]
Williams, JR [1 ]
HashemiMalayeri, B [1 ]
Stevenson, AJM [1 ]
Turnbull, CM [1 ]
机构
[1] WESTERN GEN HOSP,DEPT MED PHYS & MED ENGN,EDINBURGH EH4 2XU,MIDLOTHIAN,SCOTLAND
关键词
lung; nodule; 60.332; 60.333; lung neoplasms; CT; 60.12115; staging;
D O I
10.1148/radiology.199.3.8638014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare spiral computed tomography (CT) performed at increased pitch with spiral CT performed at standard pitch in the detection of pulmonary nodules. MATERIALS AND METHODS: Spiral CT scanning of the thorax was performed with a pitch of 1.0 in 109 patients with pulmonary nodules due to metastases. The patients were also randomly assigned to undergo further scanning with a pitch of 1.2 (n = 34), 1.5 (n = 37), or 2.0 (n = 38) at the same scanning session. The scan pairs were analyzed for number, size, and distribution of nodules. RESULTS: A bias toward undercounting was noted on scans with a pitch of 1.5 and 2.0; however, this was not statistically significant. Correlation coefficients were r = .982, r = .977, and r = .989 for scans of pitch 1.2, 1.5, and 2.0, respectively. Disease in one patient would have been prospectively understaged from findings on a scan of pitch 2.0 because of poor conspicuity of a small solitary nodule. CONCLUSION: Findings from scans with increased pitch generally agree well with those from scans with standard pitch; however, there is a greater risk of understaging of disease in patients with solitary nodules as pitch increases. Pitch should be limited to no greater than 1.5 for initial staging of pulmonary metastatic disease.
引用
收藏
页码:837 / 841
页数:5
相关论文
共 50 条
  • [41] Small pulmonary nodules: Detection at chest CT and outcome
    Benjamin, MS
    Drucker, EA
    McLoud, TC
    Shepard, JAO
    RADIOLOGY, 2003, 226 (02) : 489 - 493
  • [42] EXTENDED PITCH THORACIC SPIRAL CT
    SINGER, PS
    HOPPER, KD
    JOZEFIAK, JA
    PATRONE, SV
    KASALES, CJ
    MAHRAJ, RP
    RADIOLOGY, 1995, 197 : 202 - 202
  • [43] Detection of pulmonary nodules at spiral CT: comparison of maximum intensity projection sliding slabs and single-image reporting
    S. Diederich
    M. Lentschig
    T. Overbeck
    D. Wormanns
    W. Heindel
    European Radiology, 2001, 11 : 1345 - 1350
  • [44] Detection of pulmonary nodules at spiral CT: comparison of maximum intensity projection sliding slabs and single-image reporting
    Diederich, S
    Lentschig, MG
    Overbeck, TR
    Wormanns, D
    Heindel, W
    EUROPEAN RADIOLOGY, 2001, 11 (08) : 1345 - 1350
  • [45] The effectiveness of deep learning model in differentiating benign and malignant pulmonary nodules on spiral CT
    Liu, Dongquan
    Zhao, Yonggang
    Liu, Bangquan
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (06) : 5129 - 5140
  • [46] Characterization of pulmonary nodules at low radiation dose using wavelet local spiral CT
    Slone, RM
    Zhao, S
    Bae, KT
    Wang, G
    RADIOLOGY, 1997, 205 : 1051 - 1051
  • [47] Dictionary Learning-based CT Detection of Pulmonary Nodules
    Wu, Panpan
    Xia, Kewen
    Zhang, Yanbo
    Qian, Xiaohua
    Wang, Ge
    Yu, Hengyong
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [48] Computer-aided detection in screening CT for pulmonary nodules
    Yuan, R
    Vos, PM
    Cooperberg, PL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (05) : 1280 - 1287
  • [49] Isolated Pulmonary Nodules Characteristics Detection Based on CT Images
    Qiu, Shi
    Guo, Qiang
    Zhou, Dongmei
    Jin, Yi
    Zhou, Tao
    He, Zhen'an
    IEEE ACCESS, 2019, 7 : 165597 - 165606
  • [50] Accurate registration of temporal CT images for pulmonary nodules detection
    Yan, Jichao
    Jiang, Luan
    Li, Qiang
    MEDICAL IMAGING 2017: IMAGE PROCESSING, 2017, 10133