Pulmonary nodules: Effect on detection of spiral CT pitch

被引:33
|
作者
Wright, AR [1 ]
Collie, DA [1 ]
Williams, JR [1 ]
HashemiMalayeri, B [1 ]
Stevenson, AJM [1 ]
Turnbull, CM [1 ]
机构
[1] WESTERN GEN HOSP,DEPT MED PHYS & MED ENGN,EDINBURGH EH4 2XU,MIDLOTHIAN,SCOTLAND
关键词
lung; nodule; 60.332; 60.333; lung neoplasms; CT; 60.12115; staging;
D O I
10.1148/radiology.199.3.8638014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare spiral computed tomography (CT) performed at increased pitch with spiral CT performed at standard pitch in the detection of pulmonary nodules. MATERIALS AND METHODS: Spiral CT scanning of the thorax was performed with a pitch of 1.0 in 109 patients with pulmonary nodules due to metastases. The patients were also randomly assigned to undergo further scanning with a pitch of 1.2 (n = 34), 1.5 (n = 37), or 2.0 (n = 38) at the same scanning session. The scan pairs were analyzed for number, size, and distribution of nodules. RESULTS: A bias toward undercounting was noted on scans with a pitch of 1.5 and 2.0; however, this was not statistically significant. Correlation coefficients were r = .982, r = .977, and r = .989 for scans of pitch 1.2, 1.5, and 2.0, respectively. Disease in one patient would have been prospectively understaged from findings on a scan of pitch 2.0 because of poor conspicuity of a small solitary nodule. CONCLUSION: Findings from scans with increased pitch generally agree well with those from scans with standard pitch; however, there is a greater risk of understaging of disease in patients with solitary nodules as pitch increases. Pitch should be limited to no greater than 1.5 for initial staging of pulmonary metastatic disease.
引用
收藏
页码:837 / 841
页数:5
相关论文
共 50 条
  • [1] Detection of simulated pulmonary nodules by spiral CT
    Robinson, P
    CLINICAL RADIOLOGY, 1999, 54 (04) : 272 - 272
  • [2] Effect of breathing on the detection of in vivo simulated pulmonary nodules by spiral CT
    Coakley, FV
    Cohen, MD
    Johnson, MS
    Gonin, R
    Hanna, MP
    CLINICAL RADIOLOGY, 1998, 53 (07) : 506 - 509
  • [4] COMPARISON OF SPIRAL AND CONVENTIONAL CT IN THE DETECTION OF PULMONARY NODULES
    HEYWANGKOEBRUNNER, SH
    LOMMATZSCH, B
    FINK, U
    MAYR, B
    RADIOLOGY, 1992, 185 : 131 - 131
  • [5] PULMONARY NODULES - EFFECT OF INCREASED DATA SAMPLING ON DETECTION WITH SPIRAL CT AND CONFIDENCE IN DIAGNOSIS
    BUCKLEY, JA
    SCOTT, WW
    SIEGELMAN, SS
    KUHLMAN, JE
    URBAN, BA
    BLUEMKE, DA
    FISHMAN, EK
    RADIOLOGY, 1995, 196 (02) : 395 - 400
  • [6] PULMONARY NODULES - DETECTION WITH THICK-SECTION SPIRAL CT VERSUS CONVENTIONAL CT
    REMYJARDIN, M
    REMY, J
    GIRAUD, F
    MARQUETTE, CH
    RADIOLOGY, 1993, 187 (02) : 513 - 520
  • [7] PULMONARY NODULES - IMPROVED DETECTION WITS VASCULAR SEGMENTATION AND EXTRACTION WITH SPIRAL CT
    CROISILLE, P
    SOUTO, M
    COVA, M
    WOOD, S
    AFEWORK, Y
    KUHLMAN, JE
    ZERHOUNI, EA
    RADIOLOGY, 1995, 197 (02) : 397 - 401
  • [8] Maximum intensity projection images in the detection of simulated pulmonary nodules by spiral CT
    Coakley, FV
    Cohen, MD
    Johnson, MS
    Gonin, R
    Hanna, MP
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (842): : 135 - 140
  • [9] Pulmonary nodules: Effect of section thickness on detection with multidetector CT
    Leung, AN
    Shiau, MC
    Rubin, GD
    Belts, BJ
    Chan, FP
    Coulam, CH
    RADIOLOGY, 2000, 217 : 242 - 243
  • [10] EFFECT OF SPIRAL PITCH ON THE DETECTABILITY OF PULMONARY METASTASES
    COLLIE, DA
    WRIGHT, AR
    STEVENSON, AJ
    WILLIAMS, JR
    HASHEMIMALAYERI, B
    TURNBULL, CM
    RADIOLOGY, 1995, 197 : 202 - 202