Falsely lowered FT4 and raised TSH concentrations in a patient with hyperthyroidism and human anti-mouse monoclonal antibodies

被引:11
作者
Frost, SJ [1 ]
Hine, KR
Firth, GB
Wheatley, T
机构
[1] Princess Royal Hosp, Dept Clin Biochem, Haywards Heath RH17 4EX, W Sussex, England
[2] Princess Royal Hosp, Dept Med, Haywards Heath RH17 4EX, W Sussex, England
关键词
Crohn's disease; heterophilic antibodies; interference; chemiluminescent immunoassay;
D O I
10.1177/000456329803500220
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
[No abstract available]
引用
收藏
页码:317 / 320
页数:4
相关论文
共 9 条
[1]   FALSE POSITIVE IMMUNOMETRIC ASSAYS CAUSED BY ANTI-IMMUNOGLOBULIN ANTIBODIES - A CASE-REPORT [J].
BOCK, JL ;
FURGIUELE, J ;
WENZ, B .
CLINICA CHIMICA ACTA, 1985, 147 (03) :241-246
[2]  
EKINS R, 1987, CLIN CHEM, V33, P2137
[3]   MULTIPLE SPURIOUSLY ABNORMAL THYROID-FUNCTION INDEXES DUE TO HETEROPHILIC ANTIBODIES [J].
FIAD, TM ;
DUFFY, J ;
MCKENNA, TJ .
CLINICAL ENDOCRINOLOGY, 1994, 41 (03) :391-395
[4]  
HOWANITZ PJ, 1982, CLIN CHEM, V28, P427
[5]  
KAHN BB, 1988, J CLIN ENDOCR METAB, V66, P625
[6]   Different efficacy of various blocking reagents to eliminate interferences by human antimouse antibodies with a two-site immunoassay [J].
Reinsberg, J .
CLINICAL BIOCHEMISTRY, 1996, 29 (02) :145-148
[7]   AUTOANTIBODIES AGAINST THYROID-HORMONES OR IODOTHYRONINE - IMPLICATIONS IN DIAGNOSIS, THYROID-FUNCTION, TREATMENT, AND PATHOGENESIS [J].
SAKATA, S ;
NAKAMURA, S ;
MIURA, K .
ANNALS OF INTERNAL MEDICINE, 1985, 103 (04) :579-589
[8]  
THOMPSON RJ, 1986, CLIN CHEM, V32, P476
[9]   ENDOGENOUS INTERFERENCE IN IMMUNOASSAYS IN CLINICAL-CHEMISTRY - A REVIEW [J].
WEBER, TH ;
KAPYAHO, KI ;
TANNER, P .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1990, 50 :77-82