Comparison of image quality between split-filter twin beam dual energy and single energy images in abdominal CT

被引:12
|
作者
Niu, Zhongfeng [1 ,2 ]
Chen, Jiao [1 ,2 ]
Ren, Hong [1 ,2 ]
Wang, Yang [3 ]
Tao, XinWei [3 ]
Zhan, Kun [1 ,2 ]
机构
[1] Zhejiang Univ, Sir Run Run Shaw Hosp, Dept Radiol, Coll Med, 3 East Qingchun Rd, Hangzhou 310016, Zhejiang, Peoples R China
[2] Zhejiang Univ, Sir Run Run Shaw Inst Clin Med, 3 East Qingchun Rd, Hangzhou 310016, Zhejiang, Peoples R China
[3] Siemens Healthineers, 278 Zhouzhugong Rd, Shanghai 201318, Peoples R China
关键词
Twin-beam dual-energy; Split-filter; Image quality; Abdominal CT; COMPUTED-TOMOGRAPHY; IODINE QUANTIFICATION; URIC-ACID; ATTENUATION; SEPARATION;
D O I
10.1016/j.ejrad.2019.108702
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the objective and subjective image quality between composed images from split-filter twin beam dual energy (TBDE) and single-energy computed tomography (SECT) in abdominal CT. Methods: In this prospective study, 103 patients were imaged using TBDE (n = 51) or SECT (n = 52). The CT number and noise were measured for the following six abdominal structures: liver, spleen, fat, muscle, aorta and portal vein. The normalised noise level for the liver was separately measured and compared. The consistency of the SNR and CT number was compared between the two groups. The subjective image quality was evaluated using six aspects in a blinded manner. Cohen's Kappa statistic was used to determine the level of agreement between the two radiologists. Results: For the objective image quality comparison, the SNR of all structures was higher using TBDE compared to SECT (p < 0.05). The CT value for different structures were comparable between the two groups (p > 0.05). Among all patient sizes, the noise level for TBDE images was significantly lower (7-17% reduction) compared to the SECT images (p < 0.01). Furthermore, noise reduction's magnitude increases with body size. For image quality's subjective evaluation, TBDE images are superior for certain aspects. Cohen's Kappa values (0.7634-0.8460) suggest an adequate level of agreement between the two observers. Conclusions: TBDE scan mode can yield similar or even better objective and subjective image quality at the same level of radiation than conventional SECT. Quantitatively, TBDE images have a 7-17% reduction in noise, depending on the size of the scanned body regions.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Letter to the Editor regarding "Comparison of image quality between split-filter twin beam dual energy and single energy images in abdominal CT"
    Euler, Andre
    Schindera, Sebastian T.
    EUROPEAN RADIOLOGY, 2021, 31 (06) : 4393 - 4394
  • [3] Letter to the Editor regarding “Comparison of image quality between split-filter twin beam dual energy and single energy images in abdominal CT”
    André Euler
    Sebastian T. Schindera
    European Radiology, 2021, 31 : 4393 - 4394
  • [4] Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT
    Euler, Andre
    Obmann, Markus M.
    Szucs-Farkas, Zsolt
    Mileto, Achille
    Zaehringer, Caroline
    Falkowski, Anna L.
    Winkel, David J.
    Marin, Daniele
    Stieltjes, Bram
    Krauss, Bernhard
    Schindera, Sebastian T.
    EUROPEAN RADIOLOGY, 2018, 28 (08) : 3405 - 3412
  • [5] Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT
    André Euler
    Markus M. Obmann
    Zsolt Szucs-Farkas
    Achille Mileto
    Caroline Zaehringer
    Anna L. Falkowski
    David J. Winkel
    Daniele Marin
    Bram Stieltjes
    Bernhard Krauss
    Sebastian T. Schindera
    European Radiology, 2018, 28 : 3405 - 3412
  • [6] Comparison of Radiation Dose and Image Quality Between Split-Filter Twin Beam Dual-Energy Images and Single-Energy Images in Single-Source Contrast-Enhanced Chest Computed Tomography
    Zhou, Li-Na
    Zhao, Shi-Jun
    Wang, Ruo-Bing
    Wang, Ya-Wen
    Yang, Shou-Xin
    Wu, Ning
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (06) : 888 - 893
  • [7] SPLIT-FILTER CT FOR ROUTINE DUAL ENERGY SCANNING
    RUTT, B
    FENSTER, A
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 136 (06) : 1278 - 1278
  • [8] Single source split filter dual energy: Image quality and liver lesion detection in abdominal CT
    Eichler, Mathis
    May, Matthias
    Wiesmueller, Marco
    Saake, Marc
    Heiss, Rafael
    Uder, Michael
    Wuest, Wolfgang
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 126
  • [9] Comparative study of the image quality of twin beam dual energy and single energy carotid CT angiography
    Wang, Yue
    Wang, Yang
    Hu, Peng
    Niu, Zhongfeng
    Hu, Hongjie
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 148
  • [10] Evaluation of split-filter dual-energy CT for characterization of urinary stones
    Appel, Elisabeth
    Thomas, Christoph
    Steuwe, Andrea
    Schaarschmidt, Benedikt M.
    Brook, Olga R.
    Aissa, Joel
    Hennenlotter, Joerg
    Antoch, Gerald
    Boos, Johannes
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1127):