Clinical impact of 11C-methionine PET on expected management of patients with brain neoplasm

被引:53
作者
Yamane, Tomohiko [1 ]
Sakamoto, Setsu [2 ]
Senda, Michio [1 ]
机构
[1] Inst Biomed Res & Innovat, Div Mol Imaging, Chuo Ku, Kobe, Hyogo 6500047, Japan
[2] Kobe Univ, Grad Sch Med, Dept Radiol, Kobe, Hyogo 657, Japan
关键词
C-11-Methionine; Positron emission tomography (PET); Brain neoplasm; Clinical impact; POSITRON-EMISSION-TOMOGRAPHY; IMPROVES PROGNOSTIC STRATIFICATION; LOW-GRADE GLIOMAS; MAGNETIC-RESONANCE-SPECTROSCOPY; RADIATION NECROSIS; DIFFERENTIAL-DIAGNOSIS; STEREOTACTIC RADIOSURGERY; FDG-PET; METHIONINE; MULTICENTER;
D O I
10.1007/s00259-009-1302-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We retrospectively examined the clinical efficacy of C-11-methionine positron emission tomography (C-11-MET PET) in patients with brain neoplasm, especially whether the C-11-MET PET changed the clinical management and whether the change was beneficial or detrimental. This study reviewed 89 C-11-MET PET scans for 80 patients (20 scans for initial diagnosis of brain tumor and 69 scans for differentiating tumor recurrence from radiation necrosis). Final diagnosis and the effect on the intended management were obtained from the questionnaire to the referring physicians or directly from the medical records. The diagnostic sensitivity, specificity, and accuracy for the C-11-MET PET were evaluated. Regarding the management impact, the rate of scans that caused changes in intended management was also evaluated. Moreover, the occurrence of scans having detrimental diagnostic impact (DDI) and beneficial diagnostic impact (BDI) were evaluated. Sensitivity, specificity, and accuracy of C-11-MET PET was 87.8, 80.0, and 85.9%. The intended management was changed in 50.0% of the scans. DDI and BDI were observed in 4.3 and 36.2% of the total relevant scans, respectively. C-11-MET PET can provide useful information in initial diagnosis and differentiating tumor recurrence from radiation necrosis. The intended management was changed in half of the scans. Since a few cases did not receive the requisite treatment due to false-negative results of C-11-MET PET, management decision should be made carefully, especially in the case of a negative scan.
引用
收藏
页码:685 / 690
页数:6
相关论文
共 50 条
  • [1] Clinical impact of 11C-methionine PET on expected management of patients with brain neoplasm
    Tomohiko Yamane
    Setsu Sakamoto
    Michio Senda
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 685 - 690
  • [2] 11C-methionine PET/CT findings in benign brain disease
    Nakajima, Reiko
    Kimura, Ken
    Abe, Koichiro
    Sakai, Shuji
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (06) : 279 - 288
  • [3] Accumulation of 11C-methionine in the normal pituitary gland on 11C-methionine PET
    Tomura, Noriaki
    Saginoya, Toshiyuiki
    Mizuno, Yasuaki
    Goto, Hiromi
    ACTA RADIOLOGICA, 2017, 58 (03) : 362 - 366
  • [4] Value of 11C-methionine PET in imaging brain tumours and metastases
    Glaudemans, Andor W. J. M.
    Enting, Roelien H.
    Heesters, Mart A. A. M.
    Dierckx, Rudi A. J. O.
    van Rheenen, Ronald W. J.
    Walenkamp, Annemiek M. E.
    Slart, Riemer H. J. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (04) : 615 - 635
  • [5] The performance of 11C-Methionine PET in the differential diagnosis of glioma recurrence
    Xu, Weilin
    Gao, Liansheng
    Shao, Anwen
    Zheng, Jingwei
    Zhang, Jianmin
    ONCOTARGET, 2017, 8 (53) : 91030 - 91039
  • [6] Determination of brain tumor recurrence using 11C-methionine positron emission tomography after radiotherapy
    Yamaguchi, Shigeru
    Hirata, Kenji
    Okamoto, Michinari
    Shimosegawa, Eku
    Hatazawa, Jun
    Hirayama, Ryuichi
    Kagawa, Naoki
    Kishima, Haruhiko
    Oriuchi, Noboru
    Fujii, Masazumi
    Kobayashi, Kentaro
    Kobayashi, Hiroyuki
    Terasaka, Shunsuke
    Nishijima, Ken-ichi
    Kuge, Yuji
    Ito, Yoichi M.
    Nishihara, Hiroshi
    Tamaki, Nagara
    Shiga, Tohru
    CANCER SCIENCE, 2021, 112 (10) : 4246 - 4256
  • [7] Simultaneous evaluation of brain metastasis and thoracic cancer using semiconductor 11C-methionine PET/CT imaging
    Kaneko, Koichiro
    Nagao, Michinobu
    Ueda, Kaori
    Yamamoto, Atsushi
    Sakai, Shuji
    ANNALS OF NUCLEAR MEDICINE, 2024, 38 (04) : 278 - 287
  • [8] Evaluation of the Accumulation of 11C-Methionine with Standardized Uptake Value in the Normal Brain
    Uda, Takehiro
    Tsuyuguchi, Naohiro
    Terakawa, Yuzo
    Takami, Toshihiro
    Ohata, Kenji
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (02) : 219 - 222
  • [9] Diagnostic accuracy of 11C-methionine PET in detecting neuropathologically confirmed recurrent brain tumor after radiation therapy
    Kits, Annika
    Martin, Heather
    Sanchez-Crespo, Alejandro
    Delgado, Anna F.
    ANNALS OF NUCLEAR MEDICINE, 2018, 32 (02) : 132 - 141
  • [10] 11C-methionine PET/CT findings in benign brain disease
    Reiko Nakajima
    Ken Kimura
    Koichiro Abe
    Shuji Sakai
    Japanese Journal of Radiology, 2017, 35 : 279 - 288