Prospective comparative study of negative oral contrast agents for magnetic resonance cholangiopancreatography

被引:15
作者
Morita, Satoru [1 ]
Ueno, Eiko [1 ]
Masukawa, Ai [1 ]
Suzuki, Kazufumi [1 ]
Fujimura, Mikihiko [1 ]
Hirabayashi, Nozomi [1 ]
Kojima, Shinya [1 ]
Hirata, Masami [1 ]
Kitajima, Kazuhiro [2 ]
Kaji, Yasushi [2 ]
机构
[1] Tokyo Womens Med Univ, Med Ctr E, Dept Radiol, Arakawa Ku, Tokyo 1168567, Japan
[2] Dokkyo Univ, Sch Med, Dept Radiol, Mibu, Tochigi, Japan
来源
JAPANESE JOURNAL OF RADIOLOGY | 2010年 / 28卷 / 02期
关键词
Oral contrast agent; MRCP; Bothdel; Manganese chloride tetrahydrate; MRI; MR CHOLANGIOPANCREATOGRAPHY; UROGRAPHY; JUICE;
D O I
10.1007/s11604-009-0395-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose. The aim of this study was to compare prospectively the image quality of magnetic resonance cholangiopancreatography ( MRCP) using manganese chloride tetrahydrate (Bothdel Oral Solution 10) (MCT), a new negative oral contrast agent; ferric ammonium citrate ( FerriSeltz powder 20%) (FAC); and no agent. Materials and methods. MRCP images (TE 970 ms) of patients administered MCT (n = 19) or FAC ( n = 20) at random, and 18 patients without an agent were evaluated. The subjective image quality of the overall, extrahepatic bile duct, and pancreatic duct and the degree of elimination of gastrointestinal fluid scored by two radiologists blinded to information regarding the agent were compared using Mann-Whitney's U-test. Results. The degrees of elimination of gastroduodenal fluid of MCT and FAC were significantly better than those without an agent ( P < 0.01 and P < 0.01). The subjective image quality of MCT of the overall and extrahepatic bile duct were significantly better, although no significant differences for FAC were observed compared with those without an agent ( P < 0.01 and P = 0.21, P = 0.02 and P = 0.16). There were no significant differences for the pancreatic duct ( P = 0.12 and P = 0.19), nor were there any significant differences in the evaluations between MCT and FAC ( P = 0.19-0.98). Conclusion. MCT has shown performance comparable to that of conventional FAC in terms of pancreatic and biliary depiction and safety.
引用
收藏
页码:117 / 122
页数:6
相关论文
共 15 条
  • [1] FUJITA O, 1996, NIPPON HOSHASEN GIJU, V52, P1613
  • [2] HASEGAWA H, 1996, NIPPON HOSHASEN GIJU, V52, P1627
  • [3] BLUEBERRY JUICE - PRELIMINARY EVALUATION AS AN ORAL CONTRAST AGENT IN GASTROINTESTINAL MR-IMAGING
    HIRAISHI, K
    NARABAYASHI, I
    FUJITA, O
    YAMAMOTO, K
    SAGAMI, A
    HISADA, Y
    SAIKA, Y
    ADACHI, I
    HASEGAWA, H
    [J]. RADIOLOGY, 1995, 194 (01) : 119 - 123
  • [4] LARGE-SCALE CLINICAL-EVALUATION OF BOWEL CONTRAST AGENT CONTAINING FERRIC AMMONIUM CITRATE IN MRI
    HIROHASHI, S
    UCHIDA, H
    YOSHIKAWA, K
    FUJITA, N
    OHTOMO, K
    YUASA, Y
    KAWAMURA, Y
    MATSUI, O
    [J]. MAGNETIC RESONANCE IMAGING, 1994, 12 (06) : 837 - 846
  • [5] MR cholangiopancreatography and MR urography: Improved enhancement with a negative oral contrast agent
    Hirohashi, S
    Hirohashi, R
    Uchida, H
    Kitano, S
    Ono, W
    Ohnishi, H
    Nakanishi, S
    [J]. RADIOLOGY, 1997, 203 (01) : 281 - 285
  • [6] Lecesne R, 1998, J RADIOL, V79, P573
  • [7] The utility of MRCP in preoperative mapping of biliary anatomy in adult-to-adult living related liver transplant donors
    Limanond, P
    Raman, SS
    Ghobrial, RM
    Busuttil, RW
    Lu, DSK
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (02) : 209 - 215
  • [8] Improvement of image quality in MR cholangiography.
    Obenauer, S
    Fischer, U
    Heuser, M
    Wilke, R
    Grabbe, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 171 (06): : 450 - 454
  • [9] The value of negative oral contrast material in MR cholangiopancreatography
    Petersein, J
    Reisinger, W
    Mutze, S
    Hamm, B
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (01): : 55 - 60
  • [10] Pineapple juice as a negative oral contrast agent in magnetic resonance cholangiopancreatography: a preliminary evaluation
    Riordan, RD
    Khonsari, M
    Jeffries, J
    Maskell, GF
    Cook, PG
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (924) : 991 - 999