Personalizing flow-diverter intervention for cerebral aneurysms: from computational hemodynamics to biochemical modeling

被引:32
作者
Peach, T. W. [1 ,2 ]
Ngoepe, M. [1 ,2 ]
Spranger, K. [1 ,2 ]
Zajarias-Fainsod, D. [1 ,2 ]
Ventikos, Y. [3 ]
机构
[1] Univ Oxford, Inst Biomed Engn, Oxford OX1 3PJ, England
[2] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
[3] UCL, Dept Mech Engn, London WC1E 7JE, England
基金
英国工程与自然科学研究理事会;
关键词
finite element analysis (FEA); patient specific modeling; cerebral aneurysm; flow-diverting stent; hemodynamics; thrombosis; INTRACRANIAL ANEURYSMS; LATTICE BOLTZMANN; STENT DESIGN; BLOOD-FLOW; DYNAMICS; SIMULATION; VELOCITY; VESSELS;
D O I
10.1002/cnm.2663
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents the computational modeling of a variety of flow-diverting stents, deployed in a number of patient-specific aneurysm geometries. We consider virtual device deployment and hemodynamics as well as thrombus formation, with the scope to assess pre-operatively the efficacy of specific devices in treating particular aneurysms. An algorithm based on a linear and torsional spring analogy is developed for the fast virtual deployment of stents and similar minimally invasive devices in patient-specific vessel geometries. The virtual deployment algorithm is used to accurately deploy a total of four stent designs in three aneurysm geometries. A variety of different flow-diverting stent designs, representing the commercially available and the entirely novel, are presented, varying in both mesh design and porosity. Transient computational hemodynamics simulations are performed on multiple patient-specific geometries to predict the reduction in aneurysm inflow after the deployment of each device. Further, a thrombosis initiation and growth model is implemented, coupled with the hemodynamic computations. Hemodynamic simulations show large variations in flow reduction between devices and across different aneurysm geometries. The industry standard of flow-diverters with 70% porosity, assumed to offer the best compromise in flexibility and flow reduction, is challenged in at least one aneurysm geometry. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:1387 / 1407
页数:21
相关论文
共 50 条
  • [31] Role of patient-specific blood properties in computational fluid dynamics simulation of flow diverter deployed cerebral aneurysms
    Uchiyama, Yuya
    Fujimura, Soichiro
    Takao, Hiroyuki
    Suzuki, Takashi
    Ishibashi, Toshihiro
    Otani, Katharina
    Karagiozov, Kostadin
    Fukudome, Koji
    Yamamoto, Hideki
    Yamamoto, Makoto
    Murayama, Yuichi
    TECHNOLOGY AND HEALTH CARE, 2022, 30 (04) : 839 - 850
  • [32] Efficacy and Safety of Flow-Diverter Therapy for Recurrent Aneurysms after Stent-Assisted Coiling
    Park, K. Y.
    Yeon, J. Y.
    Kim, B. M.
    Jeon, P.
    Kim, J. -H.
    Jang, C. K.
    Kim, D. J.
    Lee, J. W.
    Kim, Y. B.
    Chung, J.
    Song, D. H.
    Park, H. G.
    Park, J. S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2020, 41 (04) : 663 - 668
  • [33] Endovascular treatment of intracranial aneurysms with flow-diverter stents: preliminary single-centre experience
    Malatesta, Emanuele
    Nuzzi, Nunzio Paolo
    Divenuto, Ignazio
    Fossaceca, Rita
    Lombardi, Mariangela
    Cerini, Paolo
    Guzzardi, Giuseppe
    Stecco, Alessandro
    Andreula, Cosma
    Carriero, Alessandro
    RADIOLOGIA MEDICA, 2013, 118 (06): : 971 - 983
  • [34] Influence of Anatomic Changes on the Outcomes of Carotid Siphon Aneurysms After Deployment of Flow-Diverter Stents
    Waihrich, Eduardo
    Clavel, Pierre
    Mendes, George
    Iosif, Christina
    Kessler, Iruena Moraes
    Mounayer, Charbel
    NEUROSURGERY, 2018, 83 (06) : 1226 - 1233
  • [35] Clinical Results of Flow Diverter Treatments for Cerebral Aneurysms under Local Anesthesia
    Rajbhandari, Saujanya
    Matsukawa, Hidetoshi
    Uchida, Kazutaka
    Shirakawa, Manabu
    Yoshimura, Shinichi
    BRAIN SCIENCES, 2022, 12 (08)
  • [36] Study and modeling of the thrombosis of small cerebral aneurysms, with and without flow diverter, by the lattice Boltzmann method
    Mezali, Farouk
    Naima, Khatir
    Benmamar, Saida
    Liazid, Abdelkrim
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 233
  • [37] Flow diverter effect of LVIS stent on cerebral aneurysm hemodynamics: a comparison with Enterprise stents and the Pipeline device
    Wang, Chao
    Tian, Zhongbin
    Liu, Jian
    Jing, Linkai
    Paliwal, Nikhil
    Wang, Shengzhang
    Zhang, Ying
    Xiang, Jianping
    Siddiqui, Adnan H.
    Meng, Hui
    Yang, Xinjian
    JOURNAL OF TRANSLATIONAL MEDICINE, 2016, 14
  • [38] Cerebral Aneurysms Treated with Flow-Diverting Stents: Computational Models with Intravascular Blood Flow Measurements
    Levitt, M. R.
    McGah, P. M.
    Aliseda, A.
    Mourad, P. D.
    Nerva, J. D.
    Vaidya, S. S.
    Morton, R. P.
    Ghodke, B. V.
    Kim, L. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (01) : 143 - 148
  • [39] Treatment of Unruptured Distal Anterior Circulation Aneurysms with Flow-Diverter Stents: A Meta-Analysis
    Cagnazzo, F.
    Perrini, P.
    Dargazanli, C.
    Lefevre, P-H
    Gascou, G.
    Morganti, R.
    di Carlo, D.
    Derraz, I
    Riquelme, C.
    Bonafe, A.
    Costalat, V
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (04) : 687 - 693
  • [40] Computational Fluid Dynamics modeling of contrast transport in basilar aneurysms following flow-altering surgeries
    Vali, Alireza
    Abla, Adib A.
    Lawton, Michael T.
    Saloner, David
    Rayz, Vitaliy L.
    JOURNAL OF BIOMECHANICS, 2017, 50 : 195 - 201