Personalizing flow-diverter intervention for cerebral aneurysms: from computational hemodynamics to biochemical modeling

被引:32
作者
Peach, T. W. [1 ,2 ]
Ngoepe, M. [1 ,2 ]
Spranger, K. [1 ,2 ]
Zajarias-Fainsod, D. [1 ,2 ]
Ventikos, Y. [3 ]
机构
[1] Univ Oxford, Inst Biomed Engn, Oxford OX1 3PJ, England
[2] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
[3] UCL, Dept Mech Engn, London WC1E 7JE, England
基金
英国工程与自然科学研究理事会;
关键词
finite element analysis (FEA); patient specific modeling; cerebral aneurysm; flow-diverting stent; hemodynamics; thrombosis; INTRACRANIAL ANEURYSMS; LATTICE BOLTZMANN; STENT DESIGN; BLOOD-FLOW; DYNAMICS; SIMULATION; VELOCITY; VESSELS;
D O I
10.1002/cnm.2663
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents the computational modeling of a variety of flow-diverting stents, deployed in a number of patient-specific aneurysm geometries. We consider virtual device deployment and hemodynamics as well as thrombus formation, with the scope to assess pre-operatively the efficacy of specific devices in treating particular aneurysms. An algorithm based on a linear and torsional spring analogy is developed for the fast virtual deployment of stents and similar minimally invasive devices in patient-specific vessel geometries. The virtual deployment algorithm is used to accurately deploy a total of four stent designs in three aneurysm geometries. A variety of different flow-diverting stent designs, representing the commercially available and the entirely novel, are presented, varying in both mesh design and porosity. Transient computational hemodynamics simulations are performed on multiple patient-specific geometries to predict the reduction in aneurysm inflow after the deployment of each device. Further, a thrombosis initiation and growth model is implemented, coupled with the hemodynamic computations. Hemodynamic simulations show large variations in flow reduction between devices and across different aneurysm geometries. The industry standard of flow-diverters with 70% porosity, assumed to offer the best compromise in flexibility and flow reduction, is challenged in at least one aneurysm geometry. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:1387 / 1407
页数:21
相关论文
共 50 条
  • [21] Flow-Diverter Stent for the Endovascular Treatment of Intracranial Aneurysms A Prospective Study in 29 Patients With 34 Aneurysms
    Lubicz, Boris
    Collignon, Laurent
    Raphaeli, Gai
    Pruvo, Jean-Pierre
    Bruneau, Michael
    De Witte, Olivier
    Leclerc, Xavier
    STROKE, 2010, 41 (10) : 2247 - 2253
  • [22] Stretchable, Implantable, Nanostructured Flow-Diverter System for Quantification of Intra-aneurysmal Hemodynamics
    Howe, Connor
    Mishra, Saswat
    Kim, Yun-Soung
    Chen, Yanfei
    Ye, Sang-Ho
    Wagner, William R.
    Jeong, Jae-Woong
    Byun, Hun-Soo
    Kim, Jong-Hoon
    Chun, Youngjae
    Yeo, Woon-Hong
    ACS NANO, 2018, 12 (08) : 8706 - 8716
  • [23] The Role of Hemodynamics in Intracranial Bifurcation Arteries after Aneurysm Treatment with Flow-Diverter Stents
    Narata, A. P.
    de Moura, F. S.
    Larrabide, I.
    Perrault, C. M.
    Patat, F.
    Bibi, R.
    Velasco, S.
    Januel, A. -C.
    Cognard, C.
    Chapot, R.
    Bouakaz, A.
    Sennoga, C. A.
    Marzo, A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (02) : 323 - 330
  • [24] Computational Hemodynamics in Cerebral Aneurysms: The Effects of Modeled Versus Measured Boundary Conditions
    Marzo, Alberto
    Singh, Pankaj
    Larrabide, Ignacio
    Radaelli, Alessandro
    Coley, Stuart
    Gwilliam, Matt
    Wilkinson, Iain D.
    Lawford, Patricia
    Reymond, Philippe
    Patel, Umang
    Frangi, Alejandro
    Hose, D. Rod
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (02) : 884 - 896
  • [25] Computational Study of Hemodynamic Changes Induced by Overlapping and Compacting of Stents and Flow Diverter in Cerebral Aneurysms
    Kim, Sunghan
    Yang, Hyeondong
    Hong, Ineui
    Oh, Je Hoon
    Kim, Yong Bae
    FRONTIERS IN NEUROLOGY, 2021, 12
  • [26] Multiphoton microscopy for pre-clinical evaluation of flow-diverter stents for treating aneurysms
    Bardet, Sylvia M.
    Cortese, Jonathan
    Blanc, Raphael
    Mounayer, Charbel
    Rouchaud, Aymeric
    JOURNAL OF NEURORADIOLOGY, 2021, 48 (03) : 200 - 206
  • [27] Tubridge flow diverter for the treatment of recurrent cerebral aneurysms
    Zhao, Li
    Wang, Jiaxiong
    Liu, Hailong
    Xie, Dajiang
    NEUROLOGY ASIA, 2024, 29 (01) : 79 - 85
  • [28] CFD Study on the Efficacy of Flow Diverter Stent Placement for Cerebral Aneurysms
    Ito, Y.
    Cho, I
    Sakai, Y.
    Iwano, K.
    JOURNAL OF APPLIED FLUID MECHANICS, 2021, 14 (05) : 1547 - 1558
  • [29] Association between hemodynamics, morphology, and rupture risk of intracranial aneurysms: a computational fluid modeling study
    Qiu, Tianlun
    Jin, Guoliang
    Xing, Haiyan
    Lu, Haitao
    NEUROLOGICAL SCIENCES, 2017, 38 (06) : 1009 - 1018
  • [30] A Review of Computational Hemodynamics in Middle Cerebral Aneurysms and Rheological Models for Blood Flow
    Campo-Deano, Laura
    Oliveira, Monica S. N.
    Pinho, Fernando T.
    APPLIED MECHANICS REVIEWS, 2015, 67 (03)