Scatter and attenuation corrections for a PEM detector using List-Mode OSEM

被引:0
|
作者
Ferreira, Claudia S. [1 ,2 ]
Cao, Liji [3 ]
Bugalho, Ricardo [2 ]
Matela, Nuno [1 ]
Ortigao, Catarina [2 ]
Varela, Joao [2 ]
Almeida, Pedro [1 ]
机构
[1] Univ Lisbon, Fac Ciencias, Inst Biofis & Engn Biomed, Lisbon, Portugal
[2] LIP Lab Instrumentacao & Fis Expt Particulas, Lisbon, Portugal
[3] German Canc Res Ctr, Div Med Phys Radiol, Heidelberg, Germany
来源
2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2013年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Emission Tomography imaging techniques are known for its quantitative potential. As in whole-body Positron Emission Tomography (PET), also in breast dedicated Positron Emission Mammography (PEM) systems, this goal can only be achieved if a set of corrections for known physics processes is implemented thoroughly. Corrections for Compton scattered events, photon attenuation and random events are examples of such important data corrections. In this work, we report the performance of scatter and attenuation corrections, specifically implemented for PEM. These correction methods were tested on data from the ClearPEM scanner, a dual-head planar system. The ClearPEM scanner does not incorporate transmission images for attenuation correction. With no anatomical information available, the PEM emission image was used to obtain the acquisition's characteristics needed as input for both the Monte Carlo (MC) based scatter correction method and the attenuation correction algorithm. A MC scatter correction can accurately model the scatter distribution of a PEM acquisition, but removing this estimate from the acquired data can result in a severe bias and increased noise in low counts PEM studies. To avoid such drawbacks, an approach based on a smoothed imaged of the scatter distribution was used. Due to the typically low counts nature of PEM acquisitions, correction procedures were combined with a 3D-OSEM-LM reconstruction, so reconstructed images could be obtained in a short period of time. Results demonstrated that both corrections perform as expected. The presence of scattered events was strongly reduced. Counts loss due to photon attenuation was clearly compensated, along with the recovery of the correct activity distribution.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Fast List-Mode Reconstruction for Time-of-Flight PET Using Graphics Hardware
    Pratx, Guillem
    Surti, Suleman
    Levin, Craig
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 105 - 109
  • [42] 4π Compton imaging using a 3-D position-sensitive CdZnTe detector via weighted list-mode maximum likelihood
    Lehner, CE
    He, Z
    Zhang, F
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3691 - 3694
  • [43] Improved Clinical Parametric Imaging Using List-Mode Reconstruction via Resolution Modeling
    Sureau, F. C.
    Comtat, C.
    Reader, A. J.
    Leroy, C.
    Santiago-Ribeiro, M. J.
    Buvat, I.
    Trebossen, R.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3507 - 3510
  • [44] Bulk motion detection and correction using list-mode data for cardiac PET imaging
    Sun, Tao
    Petibon, Yoann
    Han, Paul
    Ma, Chao
    Kim, Sally J. W.
    Alpert, Nathaniel M.
    El Fakhri, Georges
    Ouyang, Jinsong
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [45] Comparative Monte Carlo study on the performance of integration-and list-mode detector configurations for carbon ion computed tomography
    Meyer, Sebastian
    Gianoli, Chiara
    Magallanes, Lorena
    Kopp, Benedikt
    Tessonnier, Thomas
    Landry, Guillaume
    Dedes, George
    Voss, Bernd
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (03) : 1096 - 1112
  • [46] Three-Dimensional Compton Imaging Using List-Mode Maximum Likelihood Expectation Maximization
    Tornga, Shawn R.
    Sullivan, Mohini W. Rawool
    Sullivan, John P.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 1372 - 1376
  • [47] Event-by-event PET image reconstruction using list-mode origin ensembles algorithm
    Andreyev, Andriy
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [48] Demonstration of INCC6 for advanced list-mode data acquisition and analysis using ALMM
    Ogren, K.
    Henzlova, D.
    Longo, J.
    Rael, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1058
  • [49] BIVENTRICULAR FUNCTION DURING POSTEXTRASYSTOLIC POTENTIATION IN MAN - A STUDY USING LIST-MODE RADIONUCLIDE VENTRICULOGRAPHY
    POLAK, JF
    HIRSOWITZ, GS
    HOLMAN, BL
    PODRID, PJ
    LOWN, B
    INVESTIGATIVE RADIOLOGY, 1989, 24 (01) : 20 - 24
  • [50] 4-π compton imaging using a 3-D position-sensitive CdZnTe detector via weighted list-mode maximum likelihood
    Lehner, CE
    He, Z
    Zhang, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (04) : 1618 - 1624