Scatter and attenuation corrections for a PEM detector using List-Mode OSEM

被引:0
|
作者
Ferreira, Claudia S. [1 ,2 ]
Cao, Liji [3 ]
Bugalho, Ricardo [2 ]
Matela, Nuno [1 ]
Ortigao, Catarina [2 ]
Varela, Joao [2 ]
Almeida, Pedro [1 ]
机构
[1] Univ Lisbon, Fac Ciencias, Inst Biofis & Engn Biomed, Lisbon, Portugal
[2] LIP Lab Instrumentacao & Fis Expt Particulas, Lisbon, Portugal
[3] German Canc Res Ctr, Div Med Phys Radiol, Heidelberg, Germany
来源
2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2013年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Emission Tomography imaging techniques are known for its quantitative potential. As in whole-body Positron Emission Tomography (PET), also in breast dedicated Positron Emission Mammography (PEM) systems, this goal can only be achieved if a set of corrections for known physics processes is implemented thoroughly. Corrections for Compton scattered events, photon attenuation and random events are examples of such important data corrections. In this work, we report the performance of scatter and attenuation corrections, specifically implemented for PEM. These correction methods were tested on data from the ClearPEM scanner, a dual-head planar system. The ClearPEM scanner does not incorporate transmission images for attenuation correction. With no anatomical information available, the PEM emission image was used to obtain the acquisition's characteristics needed as input for both the Monte Carlo (MC) based scatter correction method and the attenuation correction algorithm. A MC scatter correction can accurately model the scatter distribution of a PEM acquisition, but removing this estimate from the acquired data can result in a severe bias and increased noise in low counts PEM studies. To avoid such drawbacks, an approach based on a smoothed imaged of the scatter distribution was used. Due to the typically low counts nature of PEM acquisitions, correction procedures were combined with a 3D-OSEM-LM reconstruction, so reconstructed images could be obtained in a short period of time. Results demonstrated that both corrections perform as expected. The presence of scattered events was strongly reduced. Counts loss due to photon attenuation was clearly compensated, along with the recovery of the correct activity distribution.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] USING GEMSTONE™ IN THE ROUTINE ANALYSIS OF CLINICAL STEM CELL LIST-MODE DATA
    Greig, Bruce W.
    Miller, David
    Herbert, Don
    Bagwell, C. Bruce
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2011, 80B (06) : 380 - 381
  • [32] Optimization of the Algorithm for the Implementation of Point Spread Function in the 3D-OSEM Reconstruction Algorithm Based on the List-Mode Micro PET Data
    Zhao, Jie
    Song, Yunfeng
    Liu, Qiong
    Chen, Shijie
    Chen, Jyh-Cheng
    ELECTRONICS, 2023, 12 (06)
  • [33] List-Mode PET Image Reconstruction Using Dykstra-Like Splitting
    Ote, Kibo
    Hashimoto, Fumio
    Onishi, Yuya
    Ouchi, Yasuomi
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2025, 9 (01) : 29 - 39
  • [34] Motion detection and characterization in PET brain scans using list-mode data
    Shaw, John
    Turkington, Timothy
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [35] ML reconstruction from dynamic list-mode PET data using temporal splines
    Verhaeghe, J
    D'Asseler, Y
    Vandenberghe, S
    Staelens, S
    Van de Walle, R
    Lemahieu, I
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3146 - 3150
  • [36] An accurate probabilistic model with detector resolution and Doppler broadening correction in list-mode MLEM reconstruction for Compton camera
    Wu, Chuanpeng
    Zhang, Siyuan
    Li, Liang
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (12)
  • [37] Combined scatter and attenuation correction for TL-201 myocardial perfusion spect using OSEM algorithm.
    Matsuoka, M
    Shinohara, H
    Yamamoto, T
    Niio, Y
    Kuniyasu, Y
    Takahashi, M
    Yokoi, T
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 299P - 299P
  • [38] Performance evaluation of the channelized Hotelling observer using bootstrap list-mode pet studies
    Groiselle, CJ
    D'Asseler, Y
    Gifford, HC
    Glick, SJ
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2511 - 2515
  • [39] Evaluation of a list-mode TOF-MLAA reconstruction with a magnitude preconditioning using GATE
    Cheng, Ju-Chieh
    Salomon, Andre
    Yaqub, Maqsood
    Boellaard, Ronald
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [40] Direct Estimation from List-Mode Data for Reversible Tracers using Graphical Modeling
    Zhu, Wentao
    Guo, Ning
    Bai, Bing
    Conti, Peter S.
    Leahy, Richard M.
    Li, Quanzheng
    2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 1204 - 1207