Scatter and attenuation corrections for a PEM detector using List-Mode OSEM

被引:0
|
作者
Ferreira, Claudia S. [1 ,2 ]
Cao, Liji [3 ]
Bugalho, Ricardo [2 ]
Matela, Nuno [1 ]
Ortigao, Catarina [2 ]
Varela, Joao [2 ]
Almeida, Pedro [1 ]
机构
[1] Univ Lisbon, Fac Ciencias, Inst Biofis & Engn Biomed, Lisbon, Portugal
[2] LIP Lab Instrumentacao & Fis Expt Particulas, Lisbon, Portugal
[3] German Canc Res Ctr, Div Med Phys Radiol, Heidelberg, Germany
来源
2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2013年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Emission Tomography imaging techniques are known for its quantitative potential. As in whole-body Positron Emission Tomography (PET), also in breast dedicated Positron Emission Mammography (PEM) systems, this goal can only be achieved if a set of corrections for known physics processes is implemented thoroughly. Corrections for Compton scattered events, photon attenuation and random events are examples of such important data corrections. In this work, we report the performance of scatter and attenuation corrections, specifically implemented for PEM. These correction methods were tested on data from the ClearPEM scanner, a dual-head planar system. The ClearPEM scanner does not incorporate transmission images for attenuation correction. With no anatomical information available, the PEM emission image was used to obtain the acquisition's characteristics needed as input for both the Monte Carlo (MC) based scatter correction method and the attenuation correction algorithm. A MC scatter correction can accurately model the scatter distribution of a PEM acquisition, but removing this estimate from the acquired data can result in a severe bias and increased noise in low counts PEM studies. To avoid such drawbacks, an approach based on a smoothed imaged of the scatter distribution was used. Due to the typically low counts nature of PEM acquisitions, correction procedures were combined with a 3D-OSEM-LM reconstruction, so reconstructed images could be obtained in a short period of time. Results demonstrated that both corrections perform as expected. The presence of scattered events was strongly reduced. Counts loss due to photon attenuation was clearly compensated, along with the recovery of the correct activity distribution.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Accelerated Regularised List-Mode PET Reconstruction Using Subset Relaxation
    Spangler-Bickell, Matthew G.
    Deller, Timothy
    Jansen, Floris
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [22] Monto Carlo Simulation Based Scatter Correction in 3D List-mode Image Reconstruction
    Lou, Kai
    Sun, Xishan
    Clark, John, Jr.
    Shao, Yiping
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [23] Incorporation of Time-of-Flight information in PET List-Mode reconstruction using a projector with accurate detector PSF modeling
    Autret, Awen
    Bert, Julien
    Strauss, Olivier
    Visvikis, Dimitris
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [24] Compensation of patient motion in PET using a rotator and list-mode reconstruction
    Chen, Yu
    Glick, J.
    King, Michael A.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2692 - 2696
  • [25] List-Mode PET Image Reconstruction Using Deep Image Prior
    Ote, Kibo
    Hashimoto, Fumio
    Onishi, Yuya
    Isobe, Takashi
    Ouchi, Yasuomi
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2023, 42 (06) : 1822 - 1834
  • [26] PET free breathing motion artifact reduction using list-mode data
    Zhao, T.
    Parikh, P.
    Hubenschmidt, J.
    Mutic, S.
    Dempsey, J.
    Malinowski, K.
    Bradley, J.
    Low, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2398 - 2398
  • [27] Fisher information analysis of list-mode SPECT emission data for joint estimation of activity and attenuation distribution
    Rahman, Md Ashequr
    Zhu, Yansong
    Clarkson, Eric
    Kupinski, Matthew A.
    Frey, Eric C.
    Jha, Abhinav K.
    INVERSE PROBLEMS, 2020, 36 (08)
  • [28] Rapid workflow of mMR PET list-mode data processing using CUDA
    Pawel Markiewicz
    Kris Thielemans
    David Atkinson
    Simon Arridge
    Brian Hutton
    Sebastien Ourselin
    EJNMMI Physics, 2 (Suppl 1)
  • [29] List-mode image reconstruction for positron emission tomography using tetrahedral voxels
    Gillam, John E.
    Angelis, Georgios I.
    Meikle, Steven R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (18) : N497 - N513
  • [30] Iterative image reconstruction using geometrically ordered subsets with list-mode data
    Popescu, LM
    Matej, S
    Lewitt, RM
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3536 - 3540