A comparison of body composition measurement techniques

被引:8
作者
Hillier, S. E. [1 ]
Beck, L.
Petropoulou, A. [1 ]
Clegg, M. E. [1 ]
机构
[1] Oxford Brookes Univ, Funct Food Ctr, Oxford OX3 0BP, England
关键词
air displacement plethysmography; bioelectrical impedance; body fat percentage; reproducibility; skinfold thickness; AIR-DISPLACEMENT PLETHYSMOGRAPHY; X-RAY ABSORPTIOMETRY; GENERALIZED EQUATIONS; 4-COMPARTMENT MODEL; SKINFOLD-THICKNESS; FAT; POD; RELIABILITY; DENSITY; ADULTS;
D O I
10.1111/jhn.12197
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: An understanding of the reproducibility of body composition measurements is essential for effective intervention studies. Air displacement plethysmography (ADP) and bioelectrical impedance (BIA) are two easy-to-use measures of body composition. The present study aimed to assess the reproducibility of ADP and BIA and compare them with each other, as well as with skinfold measurement. Methods: Forty-one participants were tested on two occasions following an overnight fast. On test day 1, participants' height, weight and % body fat (BF) were measured using ADP and BIA. Measurements were replicated to assess the within-day reproducibility. On test day 2, participants were again tested using ADP and BIA and had skinfold measurements taken. Three skinfold equations for BF calculation were applied. Comparisons of within- and between-day reproducibility and between measurement techniques were completed using Pearson correlations and Bland-Altman analysis. Results: Both Pearson correlation and Bland-Altman analysis showed good within-and between-day relationships and agreement for BF from ADP and BIA measurements. The two methods had a high correlation between them; however, the mean difference between the two was 3.1% (4.1%). From the skinfold equations used, the best agreement with ADP had a mean difference of 0.3% (0.8%) and, with BIA, had mean differences of 1.9% (4.2%). Conclusions: The data indicate that ADP and BIA cannot be used interchangeably, although both measurements had good within-and between-day agreement.
引用
收藏
页码:626 / 631
页数:6
相关论文
共 29 条
  • [1] Comparison of the Bod Pod and dual energy x-ray absorptiometry in men
    Ball, SD
    Altena, TS
    [J]. PHYSIOLOGICAL MEASUREMENT, 2004, 25 (03) : 671 - 678
  • [2] Biaggi RR, 1999, AM J CLIN NUTR, V69, P898
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] Evaluation of factors determining the precision of body composition measurements by air displacement plethysmography
    Collins, AL
    McCarthy, HD
    [J]. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2003, 57 (06) : 770 - 776
  • [5] Evaluation of the BOD POD® for assessing body fat in collegiate football players
    Collins, MA
    Millard-Stafford, ML
    Sparling, PB
    Snow, TK
    Rosskopf, LB
    Webb, SA
    Omer, J
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1999, 31 (09) : 1350 - 1356
  • [6] Comparison of percent body fat estimates using air displacement plethysmography and hydrodensitometry in adults and children
    Demerath, EW
    Guo, SS
    Chumlea, WC
    Towne, B
    Roche, AF
    Siervogel, RM
    [J]. INTERNATIONAL JOURNAL OF OBESITY, 2002, 26 (03) : 389 - 397
  • [7] DEMPSTER P, 1995, MED SCI SPORT EXER, V27, P1692
  • [8] BODY FAT ASSESSED FROM TOTAL-BODY DENSITY AND ITS ESTIMATION FROM SKINFOLD THICKNESS - MEASUREMENTS ON 481 MEN AND WOMEN AGED FROM 16 TO 72 YEARS
    DURNIN, JVGA
    WOMERSLEY, J
    [J]. BRITISH JOURNAL OF NUTRITION, 1974, 32 (01) : 77 - 97
  • [9] Body composition techniques and the four-compartment model in children
    Fields, DA
    Goran, MI
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2000, 89 (02) : 613 - 620
  • [10] Body-composition assessment via air-displacement plethysmography in adults and children: a review
    Fields, DA
    Goran, MI
    McCrory, MA
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 2002, 75 (03) : 453 - 467