Ultrasonographic optic nerve sheath diameter monitoring of elevated intracranial pressure: two case reports

被引:4
作者
Wang, Li-Juan [1 ]
Chen, Hong-Xiu [1 ]
Tong, Lan [2 ]
Chen, Li-Min [1 ]
Dong, Ya-Nan [1 ]
Xing, Ying-Qi [1 ]
机构
[1] First Hosp Jilin Univ, Dept Neurol, Changchun 130021, Peoples R China
[2] First Hosp Jilin Univ, Dept Radiol, Changchun 130021, Peoples R China
基金
中国国家自然科学基金;
关键词
Intracranial pressure (ICP); optic nerve sheath diameter (ONSD); cerebral venous sinus stenosis; venous sinus thrombosis; ultrasound; SUBARACHNOID SPACE; SONOGRAPHY; ULTRASOUND;
D O I
10.21037/atm.2019.12.16
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Ultrasonography assessments of optic nerve sheath diameter (ONSD) is a non-invasive method that may help identify elevated intracranial pressure (ICP). However, this technique was used to evaluate the elevated ICP caused by traumatic brain injury. The objective of this study was to examine clinical cases of the changes in ICP with venous sinus stenosis and venous sinus thrombosis found the advantage of this technique in the application. And we dynamically monitor ONSD and ICP as a lens for understanding the dynamic assessment for ICP. The first case of venous sinus stenosis with elevated ICP identified in real-time by changes in ONSD, which are correlated with ICP before and after stenting. Another case of venous sinus thrombosis with elevated ICE And after treatment, the patient underwent an ultrasound ONSD examination and lumbar puncture (LP) at the 1st, the 2nd and 3rd month of follow-up. The previously enlarged ONSDs retracted and LP opening pressure gradually returned to normal. These cases indicate that ONSD examination may help dynamically assess ICP changes and evaluate the efficacy of ICP treatment. These results provide utile, evidence based, preliminary clinical recommendations and indicate that ONSD examination might be a useful method of evaluating ICP, especially if repeated evaluations are needed.
引用
收藏
页数:6
相关论文
共 31 条
  • [1] Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressure
    Amini, Afshin
    Kariman, Hamid
    Dolatabadi, Ali Arhami
    Hatamabadi, Hamid Reza
    Derakhshanfar, Hojjat
    Mansouri, Behnam
    Safari, Saeed
    Eqtesadi, Razie
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (01) : 236 - 239
  • [2] Ultrasonic measurement of optic nerve sheath diameter: a non-invasive surrogate approach for dynamic, real-time evaluation of intracranial pressure
    Chen, Li-min
    Wang, Li-juan
    Hu, Yang
    Jiang, Xiao-han
    Wang, Yu-zhi
    Xing, Ying-qi
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2019, 103 (04) : 437 - 441
  • [3] Effects of acute controlled changes in end-tidal carbon dioxide on the diameter of the optic nerve sheath: a transorbital ultrasonographic study in healthy volunteers
    Dinsmore, M.
    Han, J. S.
    Fisher, J. A.
    Chan, V. W. S.
    Venkatraghavan, L.
    [J]. ANAESTHESIA, 2017, 72 (05) : 618 - 623
  • [4] Individual patient data systematic review and meta-analysis of optic nerve sheath diameter ultrasonography for detecting raised intracranial pressure: protocol of the ONSD research group.
    Dubourg J.
    Messerer M.
    Karakitsos D.
    Rajajee V.
    Antonsen E.
    Javouhey E.
    Cammarata A.
    Cotton M.
    Daniel R.T.
    Denaro C.
    Douzinas E.
    Dubost C.
    Berhouma M.
    Kassai B.
    Rabilloud M.
    Gullo A.
    Hamlat A.
    Kouraklis G.
    Mannanici G.
    Marill K.
    Merceron S.
    Poularas J.
    Ristagno G.
    Noble V.
    Shah S.
    Kimberly H.
    Cammarata G.
    Moretti R.
    Geeraerts T.
    [J]. Systematic Reviews, 2 (1) : 62
  • [5] Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis
    Dubourg, Julie
    Javouhey, Etienne
    Geeraerts, Thomas
    Messerer, Mahmoud
    Kassai, Behrouz
    [J]. INTENSIVE CARE MEDICINE, 2011, 37 (07) : 1059 - 1068
  • [6] GALETTA S, 1989, J CLIN NEURO-OPHTHAL, V9, P79
  • [7] Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients
    Geeraerts, Thomas
    Merceron, Sybille
    Benhamou, Dan
    Vigue, Bernard
    Duranteau, Jacques
    [J]. INTENSIVE CARE MEDICINE, 2008, 34 (11) : 2062 - 2067
  • [8] Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury
    Geeraerts, Thomas
    Launey, Yoann
    Martin, Laurent
    Pottecher, Julien
    Vigue, Bernard
    Duranteau, Jacques
    Benhamou, Dan
    [J]. INTENSIVE CARE MEDICINE, 2007, 33 (10) : 1704 - 1711
  • [9] Dependence of the optic nerve sheath diameter on acutely applied subarachnoidal pressure - an experimental ultrasound study
    Hansen, Hans-Christian
    Lagreze, Wolf
    Krueger, Oswald
    Helmke, Knut
    [J]. ACTA OPHTHALMOLOGICA, 2011, 89 (06) : E528 - E532
  • [10] Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: Ultrasound findings during intrathecal infusion tests
    Hansen, HC
    Helmke, K
    [J]. JOURNAL OF NEUROSURGERY, 1997, 87 (01) : 34 - 40