A low-cost device for the estimation of fluoride in drinking water

被引:0
作者
Sen, A
Rao, KK
Frizzell, MA
Rao, G
机构
[1] Univ Maryland Baltimore Cty, Dept Chem & Biochem Engn, Baltimore, MD 21250 USA
[2] Indian Inst Sci, Dept Chem Engn, Bangalore 560012, Karnataka, India
[3] Univ Maryland, Inst Biotechnol, Ctr Med Biotechnol, College Pk, MD 20742 USA
关键词
fluoride; fluorosis; colorimeter; drinking water;
D O I
10.1002/(SICI)1520-6521(1998)2:1<51::AID-FACT6>3.3.CO;2-Q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fluorosis is endemic in many regions of the world due to high (>1.5 mg I-1) levels of fluoride in groundwater. This problem is aggravated by the lack of a simple and inexpensive test for fluoride in drinking water. We discuss the design and testing of a low-cost LED-based colorimeter for estimating the fluoride concentration in water. The device was calibrated with the use of the cerium-alizarin complexone (Ce-AC) and the sodium 2-(parasulfophenylazo)-1,8-dihydroxy-3,6-naphthalene disulfonate (SPADNS) methods, which show color changes in the visible region on addition of water containing fluoride. Raw water samples collected from different parts of India were analyzed for fluoride. The fluoride concentration, as estimated by using a fluoride electrode, was in the range 0.7-1.20 mg I-1. The results obtained by the colorimeter showed good agreement with the electrode method for most of the samples. The cost of chemicals per test was $0.14 for the Ce-AC method and $0.018 for the SPADNS method. The cost of the colorimeter was about $14. (C) 1998 John Wiley & Sons, Inc.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 15 条
[1]  
*APHA AWWA WPCF, 1975, STAND METH EX WAT WA
[2]  
Belcher R., 1959, TALANTA, V2, P92, DOI [10.1016/0039-9140(59)80036-9, DOI 10.1016/0039-9140(59)80036-9]
[3]   RAPID PHOTOMETRIC DETERMINATION OF FLUORIDE IN WATER - USE OF SODIUM 2-(PARA-SULFOPHENYLAZO)-1,8-DIHYDROXYNAPHTHALENE-3,6-DISULFONATE-ZIRCONIUM LAKE [J].
BELLACK, E ;
SCHOUBOE, PJ .
ANALYTICAL CHEMISTRY, 1958, 30 (12) :2032-2034
[4]  
BULUSU KR, 1992, DEFLUORIDATION
[5]   USE OF A TOTAL IONIC STRENGTH ADJUSTMENT BUFFER FOR ELECTRODE DETERMINATION OF FLUORIDE IN WATER SUPPLIES [J].
FRANT, MS ;
ROSS, JW .
ANALYTICAL CHEMISTRY, 1968, 40 (07) :1169-&
[6]  
JINADASA KBP, 1991, INT J ENVIRON STUD, V37, P43
[7]  
Mayadevi S, 1996, INDIAN CHEM ENG A, V38, P155
[8]  
NAWLAKHE WG, 1993, CURR SCI INDIA, V65, P743
[9]  
PADMA DK, 1976, J INDIAN I SCI, V58, P280
[10]  
PHANTUMVANIT P, 1988, World Health Forum, V9, P555