Handling and efficacy of a new video-optical intubation stylet were assessed in a simulated difficult tracheal intubation setting and compared with a conventional malleable stylet. Forty-five anaesthetists performed 10 tracheal intubations using both techniques. Laryngoscopy was performed by the observer, who created a grade 3 view according the classification by Cormack and Lehane. The time taken to place the tracheal tube and the final tracheal tube positions were documented. Mean (SD) intubation time for the video-optical stylet was 20.4 (7.7) s and for the malleable stylet 10.2 (3.3) s (p < 0.01). With the video-optical stylet the trachea was correctly intubated in all 225 attempts; with the malleable stylet 14 (19.6%) oesophageal and 44 (19.6%) endobronchial intubations occurred (p < 0.01). The video-optical intubation stylet enabled us to recognise inappropriate tracheal tube positions and to correct them immediately. This equipment can be considered a reliable and effective tool for management of the difficult airway.
引用
收藏
页码:886 / 889
页数:4
相关论文
共 42 条
  • [1] Simulated difficult intubation - Comparison of the gum elastic bougie and the stylet
    Gataure, PS
    Vaughan, RS
    Latto, IP
    ANAESTHESIA, 1996, 51 (10) : 935 - 938
  • [2] Comparison between GlideRite® rigid stylet and Parker Flex-It™ stylet to facilitate GlideScope intubation in simulated difficult intubation: a randomized controlled study
    Bak, Ji Won
    Noh, Yeonji
    Kim, Juyoun
    Hwang, Byeongmun
    Kang, Seongsik
    Son, Heejeong
    Kim, Minsoo
    ANESTHESIA AND PAIN MEDICINE, 2022, 17 (01): : 104 - 111
  • [3] The SensaScope (R) - A new hybrid video intubation stylet
    Biro, Peter
    SAUDI JOURNAL OF ANAESTHESIA, 2011, 5 (04) : 411 - 413
  • [4] Awake tracheal intubation with the ProVu™ video stylet: a case series
    Harrison, S-L.
    Ahmad, I.
    Elwen, F.
    Curtis, A.
    Dua, G.
    Surda, P.
    Johnstone, C.
    ANAESTHESIA REPORTS, 2021, 9 (01) : 48 - 51
  • [5] First clinical experience of tracheal intubation with the SensaScope®, a novel steerable semirigid video stylet
    Biro, P.
    Baettig, U.
    Henderson, J.
    Seifert, B.
    BRITISH JOURNAL OF ANAESTHESIA, 2006, 97 (02) : 255 - 261
  • [6] Performance of a Plastic Optical Fiber Stylet for Tracheal Intubation of a Dog
    Dietrich Gravenstein
    Samsun Lampotang
    Richard Melker
    Richard Doviak
    Journal of Clinical Monitoring and Computing, 1998, 14 : 271 - 274
  • [7] Performance of a plastic optical fiber stylet for tracheal intubation of a dog
    Gravenstein, D
    Lampotang, S
    Melker, R
    Doviak, R
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1998, 14 (04) : 271 - 274
  • [8] Comparison of the GlideRite to the conventional malleable stylet for endotracheal intubation by the Macintosh laryngoscope: a simulation study using manikins
    Kong, Yong Tack
    Lee, Hyun Jung
    Na, Ji Ung
    Shin, Dong Hyuk
    Han, Sang Kuk
    Lee, Jeong Hun
    Choi, Pil Cho
    CLINICAL AND EXPERIMENTAL EMERGENCY MEDICINE, 2016, 3 (01): : 9 - 15
  • [9] The combination of a fiberoptic stylet and a McCoy laryngoscope facilitates tracheal intubation in difficult airway cases
    Saruki N.
    Saito S.
    Sato J.
    Takahashi T.
    Tozawa R.
    Journal of Anesthesia, 2001, 15 (3) : 132 - 135
  • [10] USE OF THE AUGUSTINE STYLET ANTICIPATING DIFFICULT TRACHEAL INTUBATION IN TREACHER-COLLINS SYNDROME
    KOVAC, AL
    JOURNAL OF CLINICAL ANESTHESIA, 1992, 4 (05) : 409 - 412