Cassette-based digital mammography

被引:10
作者
Seibert, JA
Boone, JM
Cooper, VN
Lindfors, KK
机构
[1] Univ Calif Davis, Med Ctr, Dept Radiol, Imaging Res Ctr, Sacramento, CA 95817 USA
[2] Univ Calif Los Angeles, Dept Radiol Sci, Ctr Med, Los Angeles, CA 90095 USA
关键词
digital mammography; computed radiography; digital breast imaging; CR mammography;
D O I
10.1177/153303460400300502
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Over the past several years, digital mammography systems have been installed clinically across North America in small but growing numbers. A photostimulable phosphor-based full-field digital mammography image was evaluated in this investigation. Commonly known as computed radiography (CR), its use closely mimics the screen-film mammography paradigm. System performance using modulation transfer function (MTF) and detective quantum efficiency (DQE) metrics show MTF(2.5 mm(-1)) = 0.5, DQE(2.5 mm(-1)) = 0.3, and MTF(5.0 mm(-1)) = 0.2, DQE(5.0 mm(-1)) = 0.05, for a 26 kVp beam, 0.03 mm molybdenum tube filtration, 4.5 cm tissue attenuation, and 15 mR incident exposure to the detector. Slightly higher DQE values were measured at 32 kVp with 0.025 mm rhodium tube filtration. CR mammography advantages include the ability to use existing mammography machines, where multiple rooms can be converted to "digital" operation, which allows overall cost savings compared to integrated digital mammography systems. Chief disadvantages include the labor-intensive handling of the cassettes prior to and after the imaging exam, lack of a direct interface to the x-ray system for recording technique parameters, and relatively slow processing time. Clinical experience in an IRB-approved research trial has suggested that digital mammography with photostimulable storage phosphors and a dedicated CR reader is a viable alternative to conventional screen-film mammography.
引用
收藏
页码:413 / 427
页数:15
相关论文
共 19 条
[1]   Novel computed radiography system with improved image quality by detection of emissions from both sides of an Imaging Plate [J].
Arakawa, S ;
Itoh, W ;
Kohda, K ;
Suzuki, T .
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 :572-581
[2]  
BESSON G, 2003, 2003 RSNA SCI ASS AN
[3]  
BLOOMQUIST A, 2004, 2003 RSNA SCI ASS AN
[4]   Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography [J].
Boone, JM ;
Fewell, TR ;
Jennings, RJ .
MEDICAL PHYSICS, 1997, 24 (12) :1863-1874
[5]   DQE(F) OF 4 GENERATIONS OF COMPUTED RADIOGRAPHY ACQUISITION DEVICES [J].
DOBBINS, JT ;
ERGUN, DL ;
RUTZ, L ;
HINSHAW, DA ;
BLUME, H ;
CLARK, DC .
MEDICAL PHYSICS, 1995, 22 (10) :1581-1593
[6]   Performance evaluation of a "dual-side read" dedicated mammography computed radiography system [J].
Fetterly, KA ;
Schueler, BA .
MEDICAL PHYSICS, 2003, 30 (07) :1843-1854
[7]  
FLYNN MJ, 2003, ADV DIGITAL RADIOGRA, P71
[8]   A SIMPLE METHOD FOR DETERMINING THE MODULATION TRANSFER-FUNCTION IN DIGITAL RADIOGRAPHY [J].
FUJITA, H ;
TSAI, DY ;
ITOH, T ;
DOI, K ;
MORISHITA, J ;
UEDA, K ;
OHTSUKA, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) :34-39
[9]   Screen-film and digital mammography - Image quality and radiation dose considerations [J].
Haus, AG ;
Yaffe, MJ .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2000, 38 (04) :871-+
[10]   Improving the detection of simulated masses in mammograms through two different image-processing techniques [J].
Hemminger, BM ;
Zong, SQ ;
Muller, KE ;
Coffey, CS ;
DeLuca, MC ;
Johnston, RE ;
Pisano, ED .
ACADEMIC RADIOLOGY, 2001, 8 (09) :845-855