Digital, Ultrasensitive, End-Point Protein Measurements with Large Dynamic Range via Brownian Trapping with Drift

被引:31
作者
Ge, Shencheng [1 ]
Liu, Weishan [1 ]
Schlappi, Travis [1 ]
Ismagilov, Rustem F. [1 ]
机构
[1] CALTECH, Div Chem & Chem Engn, Pasadena, CA 91125 USA
关键词
NECROSIS-FACTOR-ALPHA; SINGLE-MOLECULE DETECTION; NANOLITER PLUGS; CROHNS-DISEASE; DROPLET ARRAY; LABEL-FREE; AMPLIFICATION; PCR; ASSAYS; MICROFLUIDICS;
D O I
10.1021/ja507849b
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This communication shows that the concept of Brownian trapping with drift can be applied to improve quantitative molecular measurements. It has the potential to combine the robustness of end-point spatially resolved readouts, the ultrasensitivity of digital single-molecule measurements, and the large dynamic range of qPCR; furthermore, at low concentrations of analytes, it can provide a direct comparison of the signals arising from the analyte and from the background. It relies on the finding that molecules simultaneously diffusing, drifting (via slow flow), and binding to an array of nonsaturable surface traps have an exponentially decreasing probability of escaping the traps over time and therefore give rise to an exponentially decaying distribution of trapped molecules in space. This concept was tested with enzyme and protein measurements in a microfluidic device.
引用
收藏
页码:14662 / 14665
页数:4
相关论文
共 45 条
[1]   Detecting Proteins in Microfluidic Channels Decorated with Liquid Crystal Sensing Dots [J].
Alino, Vera Joanne ;
Sim, Puay Hoon ;
Choy, Wan Ting ;
Fraser, Angus ;
Yang, Kun-Lin .
LANGMUIR, 2012, 28 (50) :17571-17577
[2]   The pumping lid: investigating multi-material 3D printing for equipment-free, programmable generation of positive and negative pressures for microfluidic applications [J].
Begolo, Stefano ;
Zhukov, Dmitriy V. ;
Selck, David A. ;
Li, Liang ;
Ismagilov, Rustem F. .
LAB ON A CHIP, 2014, 14 (24) :4616-4628
[3]   Simple diffusion-constrained immunoassay for p24 protein with the sensitivity of nucleic acid amplification for detecting acute HIV infection [J].
Chang, Lei ;
Song, Linan ;
Fournier, David R. ;
Kan, Cheuk W. ;
Patel, Purvish P. ;
Ferrell, Evan P. ;
Pink, Brian A. ;
Minnehan, Kaitlin A. ;
Hanlon, David W. ;
Duffy, David C. ;
Wilson, David H. .
JOURNAL OF VIROLOGICAL METHODS, 2013, 188 (1-2) :153-160
[4]   Single molecule enzyme-linked immunosorbent assays: Theoretical considerations [J].
Chang, Lei ;
Rissin, David M. ;
Fournier, David R. ;
Piech, Tomasz ;
Patel, Purvish P. ;
Wilson, David H. ;
Duffy, David C. .
JOURNAL OF IMMUNOLOGICAL METHODS, 2012, 378 (1-2) :102-115
[5]   Microfluidic cartridges preloaded with nanoliter plugs of reagents: an alternative to 96-well plates for screening [J].
Chen, Delai L. ;
Ismagilov, Rustem F. .
CURRENT OPINION IN CHEMICAL BIOLOGY, 2006, 10 (03) :226-231
[6]   SlipChip [J].
Du, Wenbin ;
Li, Liang ;
Nichols, Kevin P. ;
Ismagilov, Rustem F. .
LAB ON A CHIP, 2009, 9 (16) :2286-2292
[7]   PHOTOLUMINESCENCE OF THE HOPPING DISORDERED-SYSTEMS WITH ELECTRICAL BIAS [J].
DULEA, M ;
ALDEA, A .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 1987, 90 (1-3) :461-464
[8]  
Eisele T., 1987, PROBAB THEORY REL, V74, P125
[9]   Fabrication of patterned multicomponent protein gradients and gradient arrays using microfluidic depletion [J].
Fosser, KA ;
Nuzzo, RG .
ANALYTICAL CHEMISTRY, 2003, 75 (21) :5775-5782
[10]   DIFFUSION AND DRIFT IN A MEDIUM WITH RANDOMLY DISTRIBUTED TRAPS [J].
GRASSBERGER, P ;
PROCACCIA, I .
PHYSICAL REVIEW A, 1982, 26 (06) :3686-3688