Comparison of HASTE and segmented-HASTE sequences with a T2-weighted fast spin-echo sequence in the screening evaluation of the brain

被引:32
作者
Sugahara, T
Korogi, Y
Hirai, T
Hamatake, S
Ikushima, I
Shigematu, Y
Takahashi, M
机构
[1] Department of Radiology, Kumamoto Univ. School of Medicine, Kumamoto 860
关键词
D O I
10.2214/ajr.169.5.9353469
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE, The purpose of this study was to evaluate the neuroradiologic application of half-Fourier acquisition single-shot turbo spin-echo (HASTE) and segmented-HASTE (s-HASTE) sequences in comparison with a T2-weighted fast spin-echo sequence. MATERIALS AND METHODS. First, HASTE, s-HASTE, and fast spin-echo sequences were evaluated for blurring artifacts with a stationary phantom and for motion artifacts with a moving phantom, which repeated constant or intermittent to-and-fro motions at variable intervals. Second, 30 consecutive patients with various intracranial diseases were prospectively examined with the three sequences. Lesions were classified into four groups according to size and signal intensity on fast spin-echo MR images as follows: large hyperintense, small hyperintense, small markedly hyperintense, and hypointense lesions. Signal intensities of the lesion, putamen, and gray matter were compared with the signal intensity of white matter, and contrast-to-noise ratios were calculated. Overall image quality, conspicuity of lesions, delineation of the junction between gray matter and white matter, conspicuity of the putamen, and certain types of artifacts were evaluated qualitatively. RESULTS. Ln the phantom study, the HASTE sequence was least affected by motion artifacts and the fast spin-echo sequence was most affected, although the images of the HASTE sequence were most degraded by blurring artifacts. In the clinical study, we found no significant differences among the three sequences for contrast-to-noise ratios or conspicuity of large hyperintense and small markedly hyperintense lesions. However, the contrast-to-noise ratios of hypointense lesions and gray matter, and the conspicuity of hypointense lesions were significantly poorer for the HASTE sequence than for the fast spin-echo sequence. The contrast-to-noise ratios of small hyperintense lesions and the putamen, conspicuity of small hyperintense lesions and putamen, and delineation of the junction between gray matter and white matter were significantly poorer for HASTE and s-HASTE sequences than for the fast spin-echo sequence. Ghost artifacts, which were observed during the s-HASTE sequence, were sometimes superimposed on the image. CONCLUSION. The HASTE and s-HASTE sequences afford substantial time reduction and also decrease motion artifacts and thus have potential advantages for neuroradiologic application, especially in uncooperative or unsedated children. The s-HASTE sequence may be preferable to the HASTE sequence because of fewer blurring artifacts and higher T2 contrast. However, small hyperintense and hypointense lesions may be overlooked when HASTE and s-HASTE sequences are used.
引用
收藏
页码:1401 / 1410
页数:10
相关论文
共 9 条
  • [1] GLOVER GH, 1991, RADIOLOGY, V181, P142
  • [2] CLINICAL-APPLICATIONS AND METHODOLOGICAL DEVELOPMENTS OF THE RARE TECHNIQUE
    HENNIG, J
    FRIEDBURG, H
    [J]. MAGNETIC RESONANCE IMAGING, 1988, 6 (04) : 391 - 395
  • [3] DETERMINATION OF BACKGROUND GRADIENTS WITH DIFFUSION MR-IMAGING
    JARA, H
    WEHRLI, FW
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (06): : 787 - 797
  • [4] COMPARING THE FAISE METHOD WITH CONVENTIONAL DUAL-ECHO SEQUENCES
    MELKI, PS
    MULKERN, RV
    PANYCH, LP
    JOLESZ, FA
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (03): : 319 - 326
  • [5] CONTRAST MANIPULATION AND ARTIFACT ASSESSMENT OF 2D AND 3D RARE SEQUENCES
    MULKERN, RV
    WONG, STS
    WINALSKI, C
    JOLESZ, FA
    [J]. MAGNETIC RESONANCE IMAGING, 1990, 8 (05) : 557 - 566
  • [6] MR-IMAGING OF DISEASES OF THE BRAIN - COMPARISON OF CEASE AND CONVENTIONAL SPIN-ECHO T2-WEIGHTED PULSE SEQUENCES
    PATEL, MR
    KLUFAS, RA
    SHAPIRO, AW
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (04) : 963 - 966
  • [7] BRAIN-LESIONS IN PATIENTS WITH MULTIPLE-SCLEROSIS - DETECTION WITH ECHO-PLANAR IMAGING
    SIEWERT, B
    PATEL, MR
    MUELLER, MF
    GAA, J
    DARBY, DG
    POSER, CM
    WIELOPOLSKI, PA
    EDELMAN, RR
    WARACH, S
    [J]. RADIOLOGY, 1995, 196 (03) : 765 - 771
  • [8] TRUNCATION ARTIFACTS IN MAGNETIC-RESONANCE-IMAGING
    WOOD, ML
    HENKELMAN, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1985, 2 (06) : 517 - 526
  • [9] THE CLINICAL-APPLICATIONS OF ECHO PLANAR IMAGING IN NEURORADIOLOGY
    WORTHINGTON, BS
    MANSFIELD, P
    [J]. NEURORADIOLOGY, 1990, 32 (05) : 367 - 370