Stress corrosion cracking of biodegradable Mg-4Zn alloy in simulated body fluid at different strain rates - A fractographic investigation

被引:29
|
作者
Prabhu, Deepa B. [1 ]
Dhamotharan, S. [1 ]
Sathishkumar, G. [2 ]
Gopalakrishnan, P. [3 ]
Ravi, K. R. [1 ,3 ]
机构
[1] PSG Inst Adv Studies, Struct Nanomat Lab, Coimbatore 641004, Tamil Nadu, India
[2] PSG Inst Adv Studies, Funct Innovat & Smart Text, Coimbatore 641004, Tamil Nadu, India
[3] PSG Coll Technol, Dept Met Engn, Coimbatore 641004, Tamil Nadu, India
关键词
Magnesium alloys (S); Biomaterials (S); Fracture behavior; Electron microscopy; MG-AL ALLOY; MAGNESIUM ALLOYS; PHYSIOLOGICAL ENVIRONMENT; HYDROGEN EMBRITTLEMENT; MECHANICAL INTEGRITY; BEHAVIOR; ZN; DEGRADATION; LIMITATIONS; IMPLANTS;
D O I
10.1016/j.msea.2018.06.002
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Degradable magnesium based implants are predisposed to failure by stress corrosion cracking (SCC) when subject to tensile loads in the human body. Slow strain rate (SSR) tests are used in SCC analysis and the applied strain rate is a critical factor to determine if the material failed by stress corrosion or mechanical overload. In this paper, the SCC susceptibility of Mg-4Zn alloy in simulated body fluid (SBF) is investigated at different strain rates. It was found that elongation to failure (epsilon) and ultimate tensile strength (UTS) decreased by 80% and 58% respectively when extension rate in SBF decreased from 3.6 x 10(-4) s(-1) to 3.6 x 10(-6) s(-1). When the Mg-4Zn alloy is strained in SBF, multiple surface cracks appear on the gauge, initiated at the corrosion pits that induce mechanical overload and failure at higher strain rates. As the strain rate decreases, the increased contact time between the surface and SBF results in hydrogen embrittlement, micro crack formation and progressive transgranular failure that is evident in the fractography. The reduction in UTS and elongation even at the highest strain rate tested indicate that the critical strain rate for stress corrosion cracking of Mg-4Zn alloy in simulated body fluid could be as high as 3.6 x 10(-4) s(-1).
引用
收藏
页码:223 / 231
页数:9
相关论文
共 50 条
  • [1] Elucidating the role of microstructural modification on stress corrosion cracking of biodegradable Mg-4Zn alloy in simulated body fluid
    Prabhu, Deepa B.
    Nampoothiri, Jayakrishnan
    Elakkiya, V.
    Narmadha, R.
    Selvakumar, R.
    Sivasubramanian, R.
    Gopalakrishnan, P.
    Ravi, K. R.
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 106
  • [2] Elucidating the role of microstructural modification on stress corrosion cracking of biodegradable Mg–4Zn alloy in simulated body fluid
    Prabhu, Deepa B.
    Nampoothiri, Jayakrishnan
    Elakkiya, V.
    Narmadha, R.
    Selvakumar, R.
    Sivasubramanian, R.
    Gopalakrishnan, P.
    Ravi, K.R.
    Materials Science and Engineering C, 2020, 106
  • [3] Investigating the stress corrosion cracking of a biodegradable Zn-0.8 wt%Li alloy in simulated body fluid
    Li, Guan-Nan
    Zhu, Su-Ming
    Nie, Jian-Feng
    Zheng, Yufeng
    Sun, Zhili
    BIOACTIVE MATERIALS, 2021, 6 (05) : 1468 - 1478
  • [4] Crevice corrosion behavior of a biodegradable Zn-Mn-Mg alloy in simulated body fluid
    Wang, Ting
    Zhao, An-Qi
    Yan, Yu
    Wang, Lu-Ning
    BIOMATERIALS SCIENCE, 2024, 12 (19) : 4957 - 4966
  • [5] Surface Modification of Biodegradable Mg-4Zn Alloy Using PMEDM: An Experimental Investigation, Optimization and Corrosion Analysis
    Sharma, G.
    Kumar, K.
    Satsangi, P. S.
    Sharma, N.
    IRBM, 2022, 43 (05) : 456 - 469
  • [6] In vitro investigation of biodegradable polymeric coating for corrosion resistance of Mg-6Zn-Ca alloy in simulated body fluid
    Gaur, Swati
    Raman, R. K. Singh
    Khanna, A. S.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 42 : 91 - 101
  • [7] Effect of stress corrosion cracking at various strain rates on the electrochemical corrosion behavior of Mg-Zn-In-Sn alloy
    Graduate School of Saitama Institute of Technology, Fusaiji 1690, Fukaya, Saitama 369-0293, Japan
    不详
    不详
    J. Environ. Sci., 2013, S1 (S50-S53):
  • [8] Effect of MgF2 coating on stress corrosion cracking behavior of Mg-Zn-Ca alloy in simulated body fluid
    Li, Yu-feng
    Wang, Bo-wen
    Sun, Xiao-hao
    Liu, De-bao
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2023, 33 (07) : 2044 - 2053
  • [9] Morphological studies on the development of chemical conversion coating on surface of Mg-4Zn alloy and its corrosion and bio mineralisation behaviour in simulated body fluid
    Prabhu, Deepa B.
    Gopalakrishnan, P.
    Ravi, K. R.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2020, 812
  • [10] Effect of texture and twinning on mechanical properties and corrosion behavior of an extruded biodegradable Mg-4Zn alloy
    Sabbaghian, M.
    Mahmudi, R.
    Shin, K. S.
    JOURNAL OF MAGNESIUM AND ALLOYS, 2019, 7 (04) : 707 - 716