Improving reliability of live/dead cell counting through automated image mosaicing

被引:14
作者
Piccinini, Filippo [1 ]
Tesei, Anna [2 ]
Paganelli, Giulia [2 ]
Zoli, Wainer [2 ]
Bevilacqua, Alessandro [1 ,3 ]
机构
[1] Univ Bologna, Adv Res Ctr Elect Syst ARCES Informat & Commun Te, I-40125 Bologna, Italy
[2] IRCCS, Ist Sci Romagnolo Studio Cura Tumori IRST, Meldola, FC, Italy
[3] Univ Bologna, Dept Comp Sci & Engn DISI, I-40126 Bologna, Italy
关键词
Widefield microscopy; Image processing; Oncology; Cell counting; Hemocytometer; Cancer treatments; PERFORMANCE EVALUATION; HEMATOLOGY ANALYZERS; SYSMEX XE-2100; FLOW-CYTOMETRY; IN-VITRO; MICROSCOPY; QUANTIFICATION; WHITE; ENUMERATION; SOFTWARE;
D O I
10.1016/j.cmpb.2014.09.004
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Cell counting is one of the basic needs of most biological experiments. Numerous methods and systems have been studied to improve the reliability of counting. However, at present, manual cell counting performed with a hemocytometer still represents the gold standard, despite several problems limiting reproducibility and repeatability of the counts and, at the end, jeopardizing their reliability in general. We present our own approach based on image processing techniques to improve counting reliability. It works in two stages: first building a high-resolution image of the hemocytometer's grid, then counting the live and dead cells by tagging the image with flags of different colours. In particular, we introduce GridMos (http://sourceforge.net/p/gridmos), a fully-automated mosaicing method to obtain a mosaic representing the whole hemocytometer's grid. In addition to offering more significant statistics, the mosaic "freezes" the culture status, thus permitting analysis by more than one operator. Finally, the mosaic achieved can thus be tagged by using an image editor, thus markedly improving counting reliability. The experiments performed confirm the improvements brought about by the proposed counting approach in terms of both reproducibility and repeatability, also suggesting the use of a mosaic of an entire hemocytometer's grid, then labelled trough an image editor, as the best likely candidate for the new gold standard method in cell counting. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:448 / 463
页数:16
相关论文
共 87 条
[71]   Measurement of total and differential white blood cell counts in synovial fluid by means of an automated hematology analyzer [J].
Sugiuchi, H ;
Ando, Y ;
Manabe, M ;
Nakamura, E ;
Mizuta, H ;
Nagata, S ;
Okabe, H .
JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 2005, 146 (01) :36-42
[72]   Single-cell microfluidic impedance cytometry: a review [J].
Sun, Tao ;
Morgan, Hywel .
MICROFLUIDICS AND NANOFLUIDICS, 2010, 8 (04) :423-443
[73]  
Taylor B.N., 2009, GUIDELINES EVALUATIN
[74]   User-friendly semiautomated assembly of accurate image mosaics in microscopy [J].
Thevenaz, Philippe ;
Unser, Michael .
MICROSCOPY RESEARCH AND TECHNIQUE, 2007, 70 (02) :135-146
[75]   An improved method for the automated enumeration of fluorescently labelled bacteria in human faeces [J].
Thiel, R ;
Blaut, M .
JOURNAL OF MICROBIOLOGICAL METHODS, 2005, 61 (03) :369-379
[76]   Biomass and aggregation analysis of human embryonic kidney 293 suspension cell cultures by particle size measurement [J].
Tsao, YS ;
Condon, RGG ;
Schaefer, EJ ;
Lindsay, DA ;
Liu, Z .
BIOTECHNOLOGY PROGRESS, 2000, 16 (05) :809-814
[77]   Automated Spore Measurements Using Microscopy, Image Analysis, and Peak Recognition of Near-Monodisperse Aerosols [J].
Wagner, Jeff ;
Macher, Janet .
AEROSOL SCIENCE AND TECHNOLOGY, 2012, 46 (08) :862-873
[78]  
Weber E., 2011, P 15 INT C MIN SYST, P1716
[79]  
Wojcicka A., 2012, INFORM TECHNOLOGIES
[80]   Nuclear-labeling index analysis (NLIA), a software package used to perform accurate automation of cell nuclear-labeling index analysis on immunohistochemically stained rat liver samples [J].
Xu, YH ;
Sattler, GL ;
Edwards, H ;
Pitot, HC .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2000, 63 (01) :55-70