ToF-SIMS depth profiling of insulating samples, interlaced mode or non-interlaced mode?

被引:13
作者
Wang, Zhaoying [1 ,2 ]
Jin, Ke [3 ]
Zhang, Yanwen [3 ,4 ]
Wang, Fuyi [1 ]
Zhu, Zihua [2 ]
机构
[1] Chinese Acad Sci, Inst Chem, Beijing 100190, Peoples R China
[2] Pacific NW Natl Lab, WR Wiley Environm Mol Sci Lab, Richland, WA 99354 USA
[3] Univ Tennessee, Dept Mat Sci & Engn, Knoxville, TN 37996 USA
[4] Oak Ridge Natl Lab, Mat Sci & Technol Div, Oak Ridge, TN 37831 USA
关键词
ToF-SIMS; dual-beam depth profiling; interlaced mode; non-interlaced mode; insulator; ION MASS-SPECTROMETRY; CLUSTER;
D O I
10.1002/sia.5419
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Dual-beam depth profiling strategy has been widely adopted in time-of-flight secondary ion mass spectrometry depth profiling, in which two basic operation modes, interlaced mode and non-interlaced mode, are commonly used. Generally, interlaced mode is recommended for conductive or semi-conductive samples, whereas non-interlaced mode is recommended for insulating samples, where charge compensation can be an issue. Recent publications, however, show that the interlaced mode can be used effectively for glass depth profiling, despite the fact that glass is an insulator. In this study, we provide a simple guide for choosing between interlaced mode and non-interlaced mode for insulator depth profiling. Two representative cases are presented: (i) depth profiling of a leached glass sample and (ii) depth profiling of a single-crystal MgO sample. In summary, the interlaced mode should be attempted first, because (i) it may provide data with reasonable quality, (ii) it is time-saving for most cases, and (iii) it introduces low H/C/O background. If data quality is the top priority and measurement time is flexible, non-interlaced mode is recommended because interlaced mode may suffer from low signal intensity and poor mass resolution. A big challenge is tracking trace H/C/O in a highly insulating sample (e.g., MgO), because non-interlaced mode may introduce strong H/C/O background, but interlaced mode may suffer from low signal intensity. Meanwhile, a C or Au coating is found to be very effective to improve the signal intensity. Surprisingly, the best analyzing location is not on the C or Au coating but at the edge (outside) of the coating. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:257 / 260
页数:4
相关论文
共 50 条
  • [41] Investigation of sodium ion depletion layers in electrothermally poled bioglasses by combining impedance spectroscopy with ToF-SIMS depth profiling
    Zakel, Julia
    Heddinga, Vivane
    Steinmueller, Sven Ole
    Roling, Bernhard
    SOLID STATE IONICS, 2013, 237 : 46 - 49
  • [42] ToF-SIMS Depth Profiling of Organic Films: A Comparison between Single-Beam and Dual-Beam Analysis
    Brison, J.
    Muramoto, S.
    Castner, David G.
    JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (12) : 5565 - 5573
  • [43] On the understanding of positive and negative ionization processes during ToF-SIMS depth profiling by co-sputtering with cesium and xenon
    Brison, J.
    Guillot, J.
    Douhard, B.
    Vitchev, R. G.
    Migeon, H. -N.
    Houssiau, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (03) : 519 - 524
  • [44] ToF-SIMS depth profiling of oral drug delivery films for 3D visualization of active pharmaceutical particles
    Muramoto, Shin
    GiIIen, Greg
    Collett, Cayla
    Zeissler, Cynthia J.
    Garboczi, Edward J.
    SURFACE AND INTERFACE ANALYSIS, 2020, 52 (03) : 76 - 83
  • [45] ToF-SIMS studies of carbon-fibre composite fracture surfaces and the development of controlled Mode in situ fracture
    Prickett, AC
    Smith, PA
    Watts, JF
    SURFACE AND INTERFACE ANALYSIS, 2001, 31 (01) : 11 - 17
  • [46] 3D chemical characterization of frozen hydrated hydrogels using ToF-SIMS with argon cluster sputter depth profiling
    Taylor, Michael
    Scurr, David
    Lutolf, Matthias
    Buttery, Lee
    Zelzer, Mischa
    Alexander, Morgan
    BIOINTERPHASES, 2016, 11 (02) : 1 - 7
  • [47] ToF-SIMS depth profiling analysis of the uptake of Ba2+ and Co2+ ions by natural kaolinite clay
    Shahwan, T
    Erten, HN
    Black, L
    Allen, GC
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2004, 277 (01) : 23 - 28
  • [48] Comparison study of mouse brain tissue by using ToF-SIMS within static limits and hybrid SIMS beyond static limits (dynamic mode)
    Shon, Hyun Kyong
    Son, Jin Gyeong
    Lee, Sun Young
    Moon, Jeong Hee
    Lee, Ga Seul
    Kim, Kyoung-Shim
    Lee, Tae Geol
    BIOINTERPHASES, 2023, 18 (03)
  • [49] Optimization of the depth resolution for profiling SiO2/SiC interfaces by dual-beam TOF-SIMS combined with etching
    Sameshima, Junichiro
    Takenaka, Aya
    Muraji, Yuichi
    Ogawa, Shingo
    Yoshikawa, Masanobu
    Suganuma, Katsuaki
    SURFACE AND INTERFACE ANALYSIS, 2019, 51 (07) : 743 - 753
  • [50] TOF-SIMS depth profiling of deuterated polystyrene-block-poly(n-propyl methacrylate) diblock copolymer films
    Lee, Jihye
    Yoon, Donghwan
    Shin, Kwanwoo
    Kim, Kang-Jin
    Lee, Yeonhee
    SURFACE AND INTERFACE ANALYSIS, 2010, 42 (08) : 1409 - 1416