Myocardial perfusion imaging with first-pass computed tomographic imaging: Measurement of coronary flow reserve in an animal model of regional hyperemia

被引:18
作者
Christian, Timothy F. [1 ]
Frankish, Mei Lee [1 ]
Sisemoore, Jennifer H. [1 ]
Christian, Madeline R. [1 ]
Gentchos, George [1 ]
Bell, Stephen P. [1 ]
Jerosch-Herold, Michael [2 ]
机构
[1] Univ Vermont, Coll Med, Burlington, VT 05405 USA
[2] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
Computed tomography (CT); coronary flow reserve; coronary blood flow; INCREMENTAL PROGNOSTIC VALUE; ARTERY-DISEASE; MAGNETIC-RESONANCE; CT ANGIOGRAPHY; ECHOCARDIOGRAPHY; QUANTIFICATION; PREDICTION; EXPERIENCE; ADENOSINE; ISCHEMIA;
D O I
10.1007/s12350-010-9206-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The accurate assessment of myocardial blood flow (MBF) is a potential adjunct to the anatomy of CT coronary angiography. Purpose. To compare semi-quantitative parameters from first-pass CT (FP CT) imaging with absolute measures of MBF in an animal model of altered MBF. Methods. A pig model of intracoronary adenosine (n = 8) was used during FP CT. This produces a zone with hyperemic MBF and a control zone within a slice. A subset of these animals also underwent LAD occlusion with imaging. Fluorescent microspheres (Mcsp) were injected into the left atrium to determine absolute MBF concurrent with CT imaging. Pigs were placed in a 64-slice (Philips) CT with acquisition performed during IC adenosine and occlusion. A 40% dilution of Iopamidol 370 (1 mL/kg) was injected IV at 5 mL/second. CT acquisition was ECG gated over 40 cardiac phases with the following parameters: 180 degrees axial mode (pitch = 0), field of view = 250 mmsq, 512 x 512 matrix, slice thickness = 2.5 mm x 10 slices, temporal resolution = 330 ms, 120 kV, 495 ma. Mcsp were injected immediately following CT imaging. The heart was sectioned into 2.5 mm slices to match the CT images and segmented. Time attenuation curves (TAC) were generated from CT in intervention and control zones based on Mcsp values. Mcsp coronary flow reserve (CFR) = hyperemic/control MBF, and CT CFR was derived from intervention/control area under curve from baseline corrected TIC. Results. MBF control = .65 +/- .28, MBF adenosine = 2.6 +/- .7 mL/min/g (P < .0001). CFR = 4.1 +/- 1.1, CT CFR = 4.3 +/- 1.4 (P = NS). There was a significant (r = .94, P < .0001) correlation between CFR and CT CFR. Conclusions. CT first-pass myocardial perfusion imaging is feasible using a simple semi-quantitative analysis which provides reasonable estimates of MBF. (J Nucl Cardiol 2010;17:625-30.)
引用
收藏
页码:625 / 630
页数:6
相关论文
共 24 条
[1]   Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance [J].
Al-Saadi, N ;
Nagel, E ;
Gross, M ;
Bornstedt, A ;
Schnackenburg, B ;
Klein, C ;
Klimek, W ;
Oswald, H ;
Fleck, E .
CIRCULATION, 2000, 101 (12) :1379-1383
[2]   Incremental prognostic power of single-photon emission computed tomographic myocardial perfusion imaging in patients with known or suspected coronary artery disease [J].
Borges-Neto, S ;
Shaw, LK ;
Tuttle, RH ;
Alexander, JH ;
Smith, WT ;
Chambless, M ;
Coleman, RE ;
Harrington, RA ;
Califf, RM .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (02) :182-188
[3]   PROGNOSTIC VALUE OF A CORONARY-ARTERY JEOPARDY SCORE [J].
CALIFF, RM ;
PHILLIPS, HR ;
HINDMAN, MC ;
MARK, DB ;
LEE, KL ;
BEHAR, VS ;
JOHNSON, RA ;
PRYOR, DB ;
ROSATI, RA ;
WAGNER, GS ;
HARRELL, FE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (05) :1055-1063
[4]   Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging [J].
Christian, TF ;
Rettmann, DW ;
Aletras, AH ;
Liao, SL ;
Taylor, JL ;
Balaban, RS ;
Arai, AE .
RADIOLOGY, 2004, 232 (03) :677-684
[5]   Prognostic value of dobutamine echocardiography in patients with intermediate coronary lesions at angiography [J].
Ciaroni, S ;
Bloch, A ;
Hoffmann, JL ;
Bettoni, M ;
Fournet, D .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2002, 19 (07) :549-553
[6]   Coronary 64-slice CT angiography predicts outcome in patients with known or suspected coronary artery disease [J].
Gaemperli, Oliver ;
Valenta, Ines ;
Schepis, Tiziano ;
Husmann, Lars ;
Scheffel, Hans ;
Desbiolles, Lotus ;
Leschka, Sebastian ;
Alkadhi, Hatem ;
Kaufmann, Philipp A. .
EUROPEAN RADIOLOGY, 2008, 18 (06) :1162-1173
[7]   Quantification of myocardial perfusion using dynamic 64-detector computed tomography [J].
George, Richard T. ;
Jerosch-Herold, Michael ;
Silva, Caterina ;
Kitagawa, Kakuya ;
Bluenike, David A. ;
Linia, Joao A. C. ;
Lardo, Albert C. .
INVESTIGATIVE RADIOLOGY, 2007, 42 (12) :815-822
[8]  
Gopal Ambarish, 2009, J Cardiovasc Comput Tomogr, V3, P90, DOI 10.1016/j.jcct.2009.01.003
[9]   CT coronary angiography: Quantitative assessment of myocardial perfusion using test bolus data-initial experience [J].
Groves, Ashley M. ;
Goh, Vicky ;
Rajasekharan, Sabarinath ;
Kayani, Irfan ;
Endozo, Raymondo ;
Dickson, John C. ;
Menezes, Leon J. ;
Shastry, Manu ;
Habib, Said B. ;
Ell, Peter J. ;
Hutton, Brian F. .
EUROPEAN RADIOLOGY, 2008, 18 (10) :2155-2163
[10]   Prognostic value of cardiac magnetic resonance stress tests - Adenosine stress perfusion and dobutamine stress wall motion imaging [J].
Jahnke, Cosima ;
Nagel, Eike ;
Gebker, Rolf ;
Kokocinski, Thomas ;
Kelle, Sebastian ;
Manka, Robert ;
Fleck, Eckart ;
Paetsch, Ingo .
CIRCULATION, 2007, 115 (13) :1769-1776