Design of an in-duct micro-perforated panel absorber for axial fan noise attenuation

被引:13
作者
Floss, Sebastian [2 ]
Czwielong, Felix [1 ]
Kaltenbacher, Manfred [2 ,3 ]
Becker, Stefan [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg, Inst Proc Machinery & Syst Engn, D-91054 Erlangen, Germany
[2] TU Wien, Inst Mech & Mechatron E325 3, A-1040 Vienna, Austria
[3] Graz Univ Technol, Inst Fundamentals & Theory Elect Engn, A-8010 Graz, Austria
来源
ACTA ACUSTICA | 2021年 / 5卷
关键词
Axial fans; Micro-perforated plate; Finite element method; Noise attenuation; Equivalent fluid; Duct acoustics; EMISSION; FLOW;
D O I
10.1051/aacus/2021015
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The reduction of fan noise in ducts is a challenging task for acoustic engineers. Usually, the confined space where an absorber can be integrated is small. In addition, one has to consider the influence of the absorber on the flow field and the attenuation of noise should be as great as possible. In this contribution, we investigate the application of a micro-perforated absorber (MPA) in the direct vicinity of a low-pressure axial fan operating at low Mach number conditions. The micro-perforated plates (MPP) are modeled using the Johnson-Champoux-Allard-Lafarge (JCAL) model for porous materials. The entire geometrical setup of duct, fan and MPA is then simulated with the Finite Element (FE) method; the pre-processing effort is reduced by using non-conforming grids to discretize the different regions. The influence of the cavity length and the positioning of the fan are analyzed. The results are then applied to the construction of a full-sized MPA duct component that takes the limited space into consideration. Simulation results and overall functionality are compared to experimental results obtained in an axial-fan test rig. The Finite Element framework proved to be robust in predicting overall sound pressure level reduction in the higher volume flow rates. It is also shown that the MPP increases sound reduction in the low-frequency regime and at two resonant frequencies of the MPA setup. However, its main benefit lies in maintaining the efficiency of the fan. The location of the fan downstream or within the MPA has a significant effect on both the simulated and measured sound reduction.
引用
收藏
页数:16
相关论文
共 45 条
[1]  
Abbott I. H., 1959, Theory of Wing Sections: Including a Summary of Airfoil Data
[2]   Discrete dispersion relation for hp-version finite element approximation at high wave number [J].
Ainsworth, M .
SIAM JOURNAL ON NUMERICAL ANALYSIS, 2004, 42 (02) :553-575
[3]  
Allam S., 2015, FAN 2015
[4]   Fan Noise Control Using Microperforated Splitter Silencers [J].
Allam, Sabry ;
Abom, Matsa .
JOURNAL OF VIBRATION AND ACOUSTICS-TRANSACTIONS OF THE ASME, 2014, 136 (03)
[5]  
Allard J.F., 2009, Propagation of Sound in Porous Media: Modelling Sound Absorbing Materials, V2nd ed., DOI DOI 10.1002/9780470747339
[6]  
[Anonymous], 2001, VDI 2081 BLATT 1
[7]  
[Anonymous], 2017, 5801 DIN EN ISO
[8]  
[Anonymous], 2010, 10534 DIN EN ISO
[9]   Modeling of perforated plates and screens using rigid frame porous models [J].
Atalla, Noureddine ;
Sgard, Franck .
JOURNAL OF SOUND AND VIBRATION, 2007, 303 (1-2) :195-208
[10]   Influence of the Gap Flow of Axial Vehicle Cooling Fans on Radiated Narrowband and Broadband Noise [J].
Becher, Marcus ;
Krusche, Roman ;
Tautz, Matthias ;
Mauss, Michael ;
Springer, Nils ;
Kroemer, Florian ;
Becker, Stefan .
ACTA ACUSTICA UNITED WITH ACUSTICA, 2019, 105 (03) :435-448