An analytical model to design circumferential clasps for laser-sintered removable partial dentures

被引:13
作者
Alsheghri, Ammar A. [1 ]
Alageel, Omar [2 ,3 ]
Caron, Eric [4 ]
Ciobanu, Ovidiu [2 ]
Tamimi, Faleh [2 ]
Song, Jun [1 ]
机构
[1] McGill Univ, Dept Min Mat Engn, 3610 Univ St, Montreal, PQ H3A 2B2, Canada
[2] McGill Univ, Fac Dent, Montreal, PQ, Canada
[3] King Saud Univ, Coll Appl Med Sci, Riyadh, Saudi Arabia
[4] 3DRPD Inc, Montreal, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Removable partial dentures (RPDs); Laser-sintering; Circumferential clasp design; Cobalt-chromium (Co-Cr); Plastic deformation; Fatigue failure; Finite element analysis (FEA); Undercut; Retention force; Stress; ELEMENT STRESS-ANALYSIS; RETENTION;
D O I
10.1016/j.dental.2018.06.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. Clasps of removable partial dentures (RPDs) often suffer from plastic deformation and failure by fatigue; a common complication of RPDs. A new technology for processing metal frameworks for dental prostheses based on laser-sintering, which allows for precise fabrication of clasp geometry, has been recently developed. This study sought to propose a novel method for designing circumferential clasps for laser-sintered RPDs to avoid plastic deformation or fatigue failure. Methods. An analytical model for designing clasps with semicircular cross-sections was derived based on mechanics. The Euler-Bernoulli elastic curved beam theory and Castigliano's energy method were used to relate the stress and undercut with the clasp length, cross-sectional radius, alloy properties, tooth type, and retention force. Finite element analysis (FEA) was conducted on a case study and the resultant tensile stress and undercut were compared with the analytical model predictions. Pull-out experiments were conducted on laser-sintered cobalt-chromium (Co-Cr) dental prostheses to validate the analytical model results. Results. The proposed circumferential clasp design model yields results in good agreement with FEA and experiments. The results indicate that Co-Cr circumferential clasps in molars that are 13 mm long engaging undercuts of 0.25 mm should have a cross-section radius of 1.2 mm to provide a retention of 10 N and to avoid plastic deformation or fatigue failure. However, shorter circumferential clasps such as those in premolars present high stresses and cannot avoid plastic deformation or fatigue failure. Significance. Laser-sintered Co-Cr circumferential clasps in molars are safe, whereas they are susceptible to failure in premolars. (C) 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1474 / 1482
页数:9
相关论文
共 41 条
[1]  
3TRPD, 2013, MAT SPEC COB CHROM A
[2]   Removable partial denture alloys processed by laser-sintering technique [J].
Alageel, Omar ;
Abdallah, Mohamed-Nur ;
Alsheghri, Ammar ;
Song, Jun ;
Caron, Eric ;
Tamimi, Faleh .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2018, 106 (03) :1174-1185
[3]  
Ali M., 2002, P 7 ISS TECHN DEV IN, P22
[4]   Patient satisfaction with laser-sintered removable partial dentures: A crossover pilot clinical trial [J].
Almufleh, Balqees ;
Emami, Elham ;
Alageel, Omar ;
de Melo, Fabiana ;
Seng, Francois ;
Caron, Eric ;
Nader, Samer Abi ;
Al-Hashedi, Ashwaq ;
Albuquerque, Rubens ;
Feine, Jocelyne ;
Tamimi, Faleh .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (04) :560-567
[5]  
Andel-Rahman AFR, 1999, ENG SOLID MECH FUNDA
[6]  
Anusavice K. J., 2013, PHILLIPS SCI DENT MA
[7]  
Barber JR., 2001, Applied Mechanics Reviews, V54, pB104
[8]  
Beer F.P., 2011, Mechanics of materials, V6th
[9]  
Brochard-Wyart F, 2013, CAPILLARITY WETTING
[10]   A new design for partial denture circumferential clasp arms [J].
Brockhurst, PJ .
AUSTRALIAN DENTAL JOURNAL, 1996, 41 (05) :317-323