Voxel-based comparison of state-of-the-art reconstruction algorithms for 18F-FDG PET brain imaging using simulated and clinical data

被引:13
|
作者
Vunckx, K. [1 ,2 ]
Dupont, P. [2 ,3 ]
Goffin, K. [1 ,2 ,4 ]
Van Paesschen, W. [2 ,5 ,6 ]
Van Laere, K. [1 ,2 ,4 ]
Nuyts, J. [1 ,2 ]
机构
[1] KU Leuven Univ Leuven, Dept Imaging & Pathol, B-3000 Louvain, Belgium
[2] KU Leuven Univ Leuven, Univ Hosp Leuven, Med Imaging Res Ctr, B-3000 Louvain, Belgium
[3] KU Leuven Univ Leuven, Dept Neurosci, Lab Cognit Neurol, B-3000 Louvain, Belgium
[4] Univ Hosp Leuven, Dept Nucl Med, B-3000 Louvain, Belgium
[5] KU Leuven Univ Leuven, Dept Neurosci, Lab Epilepsy Res, B-3000 Louvain, Belgium
[6] Univ Hosp Leuven, Dept Neurol, B-3000 Louvain, Belgium
关键词
Iterative reconstruction; Anatomical prior; Voxel-based comparison; F-18-FDG PET; Brain imaging; RESOLUTION RESEARCH TOMOGRAPH; PARTIAL VOLUME CORRECTION; EMISSION-TOMOGRAPHY; FDG-PET; COMPUTED-TOMOGRAPHY; MUTUAL INFORMATION; PERFORMANCE; METABOLISM; EPILEPSY; IMAGES;
D O I
10.1016/j.neuroimage.2014.06.068
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The resolution of a PET scanner (2.5-4.5 mm for brain imaging) is similar to the thickness of the cortex in the (human) brain (2.5 mm on average), hampering accurate activity distribution reconstruction. Many techniques to compensate for the limited resolution during or post-reconstruction have been proposed in the past and have been shown to improve the quantitative accuracy. In this study, state-of-the-art reconstruction techniques are compared on a voxel-basis for quantification accuracy and group analysis using both simulated and measured data of healthy volunteers and patients with epilepsy. Methods: Maximum a posteriori (MAP) reconstructions using either a segmentation-based or a segmentationless anatomical prior were compared tomaximum likelihood expectation maximization (MLEM) reconstruction with resolution recovery. As anatomical information, a spatially aligned 3D T1-weighted magnetic resonance image was used. Firstly, the algorithms were compared using normal brain images to detect systematic bias with respect to the true activity distribution, as well as systematic differences between two methods. Secondly, it was verified whether the algorithms yielded similar results in a group comparison study. Results: Significant differences were observed between the reconstructed and the true activity, with the largest errors when using (post-smoothed) MLEM. Only 5-10% underestimation in cortical gray matter voxel activity was found for both MAP reconstructions. Higher errors were observed at GM edges. MAP with the segmentation-based prior also resulted in a significant bias in the subcortical regions due to segmentation inaccuracies, while MAP with the anatomical prior which does not need segmentation did not. Significant differences in reconstructed activity were also found between the algorithms at similar locations(mainly in gray matter edge voxels and in cerebrospinal fluid voxels) in the simulated as well as in the clinical data sets. Nevertheless, when comparing two groups, very similar regions of significant hypometabolism were detected by all algorithms. Conclusion: Including anatomical a priori information during reconstruction in combination with resolution modeling yielded accurate gray matter activity estimates, and a significant improvement in quantification accuracy was found when compared to post-smoothed MLEM reconstruction with resolution modeling. AsymBowsher provided the most accurate subcortical GM activity estimates. It is also reassuring that the differences found between the algorithms did not hamper the detection of hypometabolic regions in the gray matter when performing a voxel-based group comparison. Nevertheless, the size of the detected clusters differed. More elaborated and application-specific studies are required to decide which algorithm is best for a group analysis. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:875 / 884
页数:10
相关论文
共 32 条
  • [1] Brain reserve capacity in frontotemporal dementia:: a voxel-based 18F-FDG PET study
    Perneczky, Robert
    Diehl-Schmid, Janine
    Drzezga, Alexander
    Kurz, Alexander
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (07) : 1082 - 1087
  • [2] Brain reserve capacity in frontotemporal dementia: a voxel-based 18F-FDG PET study
    Robert Perneczky
    Janine Diehl-Schmid
    Alexander Drzezga
    Alexander Kurz
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 1082 - 1087
  • [3] Voxel-Based Quantitative Analysis of Brain Images From 18F-FDG PET With a Block-Matching Algorithm for Spatial Normalization
    Person, Christophe
    Louis-Dorr, Valerie
    Poussier, Sylvain
    Commowick, Olivier
    Malandain, Gregoire
    Maillard, Louis
    Wolf, Didier
    Gillet, Nicolas
    Roch, Veronique
    Karcher, Gilles
    Marie, Pierre-Yves
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (03) : 268 - 273
  • [4] Statistical Voxel-Based Methods and [18F]FDG PET Brain Imaging: Frontiers for the Diagnosis of AD
    Gallivanone, Francesca
    Della Rosa, Pasquale Anthony
    Castiglioni, Isabella
    CURRENT ALZHEIMER RESEARCH, 2016, 13 (06) : 682 - 694
  • [5] Clinical evaluation of reconstruction and acquisition time for pediatric 18F-FDG brain PET using digital PET/CT
    Nicholas A. Shkumat
    Reza Vali
    Amer Shammas
    Pediatric Radiology, 2020, 50 : 966 - 972
  • [6] Clinical evaluation of reconstruction and acquisition time for pediatric 18F-FDG brain PET using digital PET/CT
    Shkumat, Nicholas A.
    Vali, Reza
    Shammas, Amer
    PEDIATRIC RADIOLOGY, 2020, 50 (07) : 966 - 972
  • [7] Voxel-Based Analysis of Dual-Time-Point 18F-FDG PET Images for Brain Tumor Identification and Delineation
    Prieto, Elena
    Marti-Climent, Josep Maria
    Dominguez-Prado, Ines
    Garrastachu, Puy
    Diez-Valle, Ricardo
    Tejada, Sonia
    Aristu, Jose Javier
    Penuelas, Ivan
    Arbizu, Javier
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (06) : 865 - 872
  • [8] Comparison of 18F-FDG PET/CT imaging with different dual time 18F-FDG PET/CT with forced diuresis in clinical diagnosis of prostate cancer
    Yu, Longhua
    Huang, Shiming
    Wu, Siyu
    Yue, Jianlan
    Yin, Liang
    Lin, Zhichun
    MEDICINE, 2023, 102 (02) : E32331
  • [9] Reduction of 18F-FDG Dose in Clinical PET/MR Imaging by Using Silicon Photomultiplier Detectors
    Sekine, Tetsuro
    Delso, Gaspar
    Zeimpekis, Konstantinos G.
    Barbosa, Felipe de Galiza
    ter Voert, Edwin E. G. W.
    Huellner, Martin
    Veit-Haibach, Patrick
    RADIOLOGY, 2018, 286 (01) : 249 - 259
  • [10] Correction of partial volume effect in 18F-FDG PET brain studies using coregistered MR volumes: Voxel based analysis of tracer uptake in the white matter
    Coello, Christopher
    Willoch, Frode
    Selnes, Per
    Gjerstad, Leif
    Fladby, Tormod
    Skretting, Arne
    NEUROIMAGE, 2013, 72 : 183 - 192