70 kV computed tomography of the thorax: valence for computer-assisted nodule evaluation and radiation dose - first clinical results

被引:6
作者
Bodelle, Boris [1 ]
Klement, Dorothee [1 ]
Kerl, Josef Matthias [1 ]
Lehnert, Thomas [1 ]
Frellesen, Claudia [1 ]
Bauer, Ralf [1 ]
Vogl, Thomas Josef [1 ]
Sedlmair, Martin [2 ]
Schulz, Boris [1 ]
机构
[1] Clin Goethe Univ, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Siemens Healthcare, Forchheim, Germany
关键词
Chest CT; CAD; radiation dose; 70; kV; pulmonary nodules; LUNG-CANCER; AIDED DETECTION; CT;
D O I
10.1177/0284185113513258
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Computed tomography (CT) is the gold standard for evaluation of pulmonary nodules and is at the same time responsible for the majority of the collective effective dose. Purpose: To evaluate radiation dose and efficacy of computer-assisted detection (CAD) for solid pulmonary nodules in low dose chest CT performed at 70 kV. Material and Methods: CAD was performed upon chest CT with 70 kV and 100 kV (gold standard) at manufacture's recommended tube current of 87 mAs (collimation, 64 x 0.6 mm). Detection rate for pulmonary nodules and size measurements of both techniques were compared to each other. Radiation dosage in terms of effective dose (E) was measured using an Alderson-Rando Phantom. Results: Seventy-four patients with 301 solid nodules were included in the study. CAD detection rate was similar for 70 kV (94.7%) and 100 kV (92.4%). Mean transversal nodule diameter was 5.5 mm for 70 kV and 5.7 mm for 100 kV with an average volume of 0.12 mL (both techniques). Derived from the phantom measurements patient examinations resulted in an E of 0.51 mSv (70 kV) versus 2.02 mSv (100 kV). Conclusion: 70 kV low-dose chest CT is suitable for CAD based lung nodule analysis at a fraction of the radiation burden of the standard technique. Since the measurements are highly accurate, 70 kV CT could be used for detection of pulmonal lesions as well as follow-up studies.
引用
收藏
页码:1056 / 1062
页数:7
相关论文
共 23 条
  • [11] Computer-aided detection of peripheral lung cancers missed at CT: ROC analyses without and with localization
    Li, F
    Arimura, H
    Suzuki, K
    Shiraishi, J
    Li, Q
    Abe, H
    Engelmann, R
    Sone, S
    MacMahon, H
    Doi, K
    [J]. RADIOLOGY, 2005, 237 (02) : 684 - 690
  • [12] Guidelines for management of small pulmonary nodules detected on CT scans: A statement from the Fleischner Society
    MacMahon, H
    Austin, JHM
    Gamsu, G
    Herold, CJ
    Jett, JR
    Naidich, DP
    Patz, EF
    Swensen, SJ
    [J]. RADIOLOGY, 2005, 237 (02) : 395 - 400
  • [13] The solitary pulmonary nodule
    Ost, D
    Fein, AM
    Feinsilver, SH
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (25) : 2535 - 2542
  • [14] Early lung-cancer detection with spiral CT and positron emission tomography in heavy smokers: 2-year results
    Pastorino, U
    Bellomi, M
    Landoni, C
    De Fiori, E
    Arnaldi, P
    Picchio, M
    Pelosi, G
    Boyle, P
    Fazio, F
    [J]. LANCET, 2003, 362 (9384) : 593 - 597
  • [15] Estimation and comparison of effective dose (E) in standard chest CT by organ dose measurements and dose-length-product methods and assessment of the influence of CT tube potential (energy dependency) on effective dose in a dual-source CT
    Paul, Jijo
    Banckwitz, Rosemarie
    Krauss, Bernhard
    Vogl, Thomas J.
    Maentele, Werner
    Bauer, Ralf W.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) : E507 - E512
  • [16] Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients
    Pontana, Francois
    Duhamel, Alain
    Pagniez, Julien
    Flohr, Thomas
    Faivre, Jean-Baptiste
    Hachulla, Anne-Lise
    Remy, Jacques
    Remy-Jardin, Martine
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (03) : 636 - 643
  • [17] Evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction with the same group of patients
    Qi, L-P
    Li, Y.
    Tang, L.
    Li, Y-L
    Li, X-T
    Cui, Y.
    Sun, Y-S
    Zhang, X-P
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018) : E906 - E911
  • [18] Shrimpton P.C., 2004, EUR. European guidelines for multislice computed tomography funded by the European Commission 2004: contract number FIGMCT2000-20078-CTTIP
  • [19] Radiation Dose Reduction with Hybrid Iterative Reconstruction for Pediatric CT
    Singh, Sarabjeet
    Kalra, Mannudeep K.
    Shenoy-Bhangle, Anuradha S.
    Saini, Aashna
    Gervais, Debra A.
    Westra, Sjirk J.
    Thrall, James H.
    [J]. RADIOLOGY, 2012, 263 (02) : 537 - 546
  • [20] Radiation Dose Associated With Common Computed Tomography Examinations and the Associated Lifetime Attributable Risk of Cancer
    Smith-Bindman, Rebecca
    Lipson, Jafi
    Marcus, Ralph
    Kim, Kwang-Pyo
    Mahesh, Mahadevappa
    Gould, Robert
    de Gonzalez, Amy Berrington
    Miglioretti, Diana L.
    [J]. ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) : 2078 - 2086