SSVM: An Ultra-Low-Power Strain Sensing and Visualization Module for Long-Term Structural Health Monitoring

被引:6
作者
Khan, Suleman [1 ]
Won, Jongbin [1 ]
Shin, Junsik [1 ]
Park, Junyoung [1 ]
Park, Jong-Woong [1 ]
Kim, Seung-Eock [2 ]
Jang, Yun [3 ]
Kim, Dong Joo [2 ]
机构
[1] Chung Ang Univ, Dept Civil & Environm Engn, Seoul 06974, South Korea
[2] Sejong Univ, Dept Civil & Environm Engn, 98 Gunja Dong, Seoul 143747, South Korea
[3] Sejong Univ, Comp Engn & Convergence Engn Intelligent Drone, 98 Gunja Dong, Seoul 143747, South Korea
基金
新加坡国家研究基金会;
关键词
structural health monitoring (SHM); ultra-low-power; strain sensing and visualization module (SSVM); QR code; smartphone application; cloud database; WIRELESS SENSOR NETWORKS; DEFLECTION ESTIMATION; STRESS-DISTRIBUTION; LIGHT EMISSION; SYSTEM; MECHANOLUMINESCENCE; MODEL;
D O I
10.3390/s21062211
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Structural health monitoring (SHM) is crucial for quantitative behavioral analysis of structural members such as fatigue, buckling, and crack propagation identification. However, formerly developed approaches cannot be implemented effectively for long-term infrastructure monitoring, owing to power inefficiency and data management challenges. This study presents the development of a high-fidelity and ultra-low-power strain sensing and visualization module (SSVM), along with an effective data management technique. Deployment of 24-bit resolution analog to a digital converter and precise half-bridge circuit for strain sensing are two significant factors for efficient strain measurement and power management circuit incorporating a low-power microcontroller unit (MCU), and electronic-paper display (EPD) enabled long-term operation. A prototype for SSVM was developed that performs strain sensing and encodes the strain response in a QR code for visualization on the EPD. For efficient power management, SSVM only activated when the trigger-signal was generated and stayed in power-saving mode consuming 18 mA and 337.9 mu A, respectively. The trigger-signal was designed to be generated either periodically by a timer or intentionally by a push-button. A smartphone application and cloud database were developed for efficient data acquisition and management. A lab-scale experiment was carried out to validate the proposed system with a reference strain sensing system. A cantilever beam was deflected by increasing load at its free end, and the resultant strain response of SSVM was compared with the reference. The proposed system was successfully validated to use for long-term static strain measurement.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 65 条
  • [1] Intense visible light emission from stress-activated SrMgAl6O11:Eu
    Akiyama, M
    Nishikubo, K
    Nonaka, K
    [J]. APPLIED PHYSICS LETTERS, 2003, 83 (04) : 650 - 652
  • [2] Akwukwuma V., 2012, PAC J SCI TECHNOL, V13, P173
  • [3] All about Circuits, 2021, STRAIN GAUG
  • [4] Amazon, 2021, AM AWS EC2
  • [5] Emerging Trends in Optimal Structural Health Monitoring System Design: From Sensor Placement to System Evaluation
    Barthorpe, Robert James
    Worden, Keith
    [J]. JOURNAL OF SENSOR AND ACTUATOR NETWORKS, 2020, 9 (03)
  • [6] Budiyev Y., 2021, CODE SCANNER
  • [7] Suitable materials for elastico mechanoluminescence-based stress sensors
    Chandra, V. K.
    Chandra, B. P.
    [J]. OPTICAL MATERIALS, 2011, 34 (01) : 194 - 200
  • [8] Cheng L., 2009, Nanofluid Heat Transfer Technologies, P1
  • [9] An electrophoretic ink for all-printed reflective electronic displays
    Comiskey, B
    Albert, JD
    Yoshizawa, H
    Jacobson, J
    [J]. NATURE, 1998, 394 (6690) : 253 - 255
  • [10] Developers, 2021, DEV ANDROID STUDIO