Comparative analysis of single phase transformerless inverter topologies for grid connected PV system

被引:43
作者
Ahmad, Zameer [1 ]
Singh, S. N. [1 ]
机构
[1] Indian Inst Technol, Alternate Hydro Energy Ctr, Roorkee, Uttar Pradesh, India
关键词
Leakage current; Common mode voltage; Transformerless; Photovoltaic system; PHOTOVOLTAIC SYSTEMS; CONTROLLER-DESIGN; SYNCHRONIZATION; CONVERTERS;
D O I
10.1016/j.solener.2017.03.080
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Many single phase transformerless inverter topologies with reduced leakage current have been introduced for grid tied photovoltaic (PV) applications in the past few years. These topologies are mainly classified on the basis of leakage current reduction methods: galvanic isolation with common mode voltage (CMV) clamping and without CMV clamping. The galvanic isolation can be achieved by incorporation of extra switches either on ac side or dc side of full bridge (H4) inverter topology for ac or dc decoupling respectively. Ac side decoupling offers high efficiency due to lower number of switches in conduction path. However, it has been shown that merely by galvanic isolation, leakage current cannot be reduced to zero, because of stray junction capacitances and resonant circuit effects. Some topologies utilize CMV clamping methods to fix the CMV to half of the dc bus voltage to completely eliminate the leakage current. In this paper, several recently published topologies are reviewed, analyzed and compared. The operation principles of the topologies are discussed with their switching waveforms. The performances of the topologies are compared on the basis of CMV, leakage current, semiconductor device losses, efficiency and total harmonic distortion (THD). A modified CMV clamped H6-IV topology is also proposed to improve common mode characteristics. The analyses are carried out using Matlab/Simulink simulation, and results are verified experimentally. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:245 / 271
页数:27
相关论文
共 62 条
[1]  
Abella M., 2004, RENEWABLE ENERGY WOR, V7, P132
[2]  
[Anonymous], 2003, Deutsches Patent und Markenamt, Patent No. [DE10221592A1, 10221592]
[3]  
[Anonymous], 2001, 6100032 BS EN
[4]  
[Anonymous], 154712005 IEEE
[5]   Deadbeat current controller design for multilevel grid connected inverter [J].
Atia, Yousry ;
Ahmed, Mahrous ;
Eliwa, Aref ;
Salem, Mahmoud .
3RD INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS ENGINEERING, CPESE 2016, 2016, 100 :237-242
[6]  
Azevedo GMS, 2009, PROC IEEE INT SYMP, P544
[7]   Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[8]   CURRENT CONTROL OF VSI-PWM INVERTERS [J].
BROD, DM ;
NOVOTNY, DW .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1985, 21 (03) :562-570
[9]  
Brückner T, 2005, IEEE IND APPLIC SOC, P84
[10]   Multilevel converters for single-phase grid connected photovoltaic systems: An overview [J].
Calais, M ;
Agelidis, VG ;
Meinhardt, M .
SOLAR ENERGY, 1999, 66 (05) :325-335