Comparisons of Core Temperature Between a Telemetric Pill and Heart Rate Estimated Core Temperature in Firefighters

被引:5
作者
Pearson, Stephen J. [1 ]
Highlands, Brian [2 ]
Jones, Rebecca [2 ]
Matthews, Martyn J. [1 ]
机构
[1] Univ Salford, Ctr Hlth Sport & Rehabil Sci Res, Manchester, England
[2] Greater Manchester Fire & Rescue Serv, Manchester, Lancs, England
关键词
Firefighter; Heart rate estimation; Internal temperature; Kalman filter; BODY-TEMPERATURE; EXERCISE;
D O I
10.1016/j.shaw.2021.11.003
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Firefighters may experience high environmental temperatures or carry out intensive physical tasks, or both, which leads to increased core body temperature and risk of fatalities. Hence there is a need to remotely and non-invasively monitor core body temperature.Methods: Estimated (heart rate algorithm) and actual core body temperature (ingested telemetric pill) measures were collected simultaneously for comparison during training exercises on 44 firefighter volunteers.Results: Prediction of core body temperature varied, with no specific identifiable pattern between the algorithm values and directly measured body core temperatures. Group agreement of Lin's Concordance of 0.74 (95% Upper 0.75, lower CI 0.73), was deemed poor. Conclusion: From individual agreement data Lin's Concordance was variable (Min 0.11, CI 0.13-0.01; Max 0.83, CI 0.86-0.80), indicating that the heart rate algorithm approach was not suitable for core body temperature monitoring in this population group, especially at the higher more critical core body temperatures seen.(c) 2021 Occupational Safety and Health Research Institute, Published by Elsevier Korea LLC. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:99 / 103
页数:5
相关论文
共 13 条
  • [1] Real-time core body temperature estimation from heart rate for first responders wearing different levels of personal protective equipment
    Buller, Mark J.
    Tharion, William J.
    Duhamel, Cynthia M.
    Yokota, Miyo
    [J]. ERGONOMICS, 2015, 58 (11) : 1830 - 1841
  • [2] Estimation of human core temperature from sequential heart rate observations
    Buller, Mark J.
    Tharion, William J.
    Cheuvront, Samuel N.
    Montain, Scott J.
    Kenefick, Robert W.
    Castellani, John
    Latzka, William A.
    Roberts, Warren S.
    Richter, Mark
    Jenkins, Odest Chadwicke
    Hoyt, Reed W.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2013, 34 (07) : 781 - 798
  • [3] Development of an improved wearable device for core body temperature monitoring based on the dual heat flux principle
    Feng, Jingjie
    Zhou, Congcong
    He, Cheng
    Li, Yuan
    Ye, Xuesong
    [J]. PHYSIOLOGICAL MEASUREMENT, 2017, 38 (04) : 652 - 668
  • [4] FOX R H, 1971, Journal of Physiology (Cambridge), V212, p8P
  • [5] NEW METHOD FOR MONITORING DEEP BODY-TEMPERATURE FROM SKIN SURFACE
    FOX, RH
    SOLMAN, AJ
    ISAACS, R
    FRY, AJ
    MACDONALD, IC
    [J]. CLINICAL SCIENCE, 1973, 44 (01) : 81 - 86
  • [6] Development of a new method for the noninvasive measurement of deep body temperature without a heater
    Kitamura, Kei-Ichiro
    Zhu, Xin
    Chen, Wenxi
    Nemoto, Tetsu
    [J]. MEDICAL ENGINEERING & PHYSICS, 2010, 32 (01) : 1 - 6
  • [7] Lim CL, 2008, ANN ACAD MED SINGAP, V37, P347
  • [8] McBride G., 2005, NIWA CLIENT REP, V45, P307
  • [9] Using the Bair Hugger™ temperature monitoring system in neck and chest regions: a pilot study
    Tachibana, Shunsuke
    Chida, Yutaro
    Yamakage, Michiaki
    [J]. JA CLINICAL REPORTS, 2019, 5 (1)
  • [10] Muscular contraction mode differently affects autonomic control during heart rate matched exercise
    Weippert, Matthias
    Behrens, Martin
    Gonschorek, Ray
    Bruhn, Sven
    Behrens, Kristin
    [J]. FRONTIERS IN PHYSIOLOGY, 2015, 6